메뉴 건너뛰기




Volumn 31, Issue 9, 1996, Pages 1230-1238

A 64-site multishank CMOS low-profile neural stimulating probe

Author keywords

[No Author keywords available]

Indexed keywords

CMOS INTEGRATED CIRCUITS; MICROELECTRODES; NEUROLOGY; PROBES; SILICON SENSORS;

EID: 0030243818     PISSN: 00189200     EISSN: None     Source Type: Journal    
DOI: 10.1109/4.535406     Document Type: Article
Times cited : (89)

References (13)
  • 2
    • 0014284770 scopus 로고
    • The sensations produced by electrical stimulation of the visual cortex
    • G. S. Brindley and W. S. Lewin, "The sensations produced by electrical stimulation of the visual cortex," J. Physiol., vol. 196, pp. 479-493, 1968.
    • (1968) J. Physiol. , vol.196 , pp. 479-493
    • Brindley, G.S.1    Lewin, W.S.2
  • 3
    • 0019999648 scopus 로고
    • Review of current status of cochlear prostheses
    • Apr.
    • R. L. White, "Review of current status of cochlear prostheses," IEEE Trans. Biomed. Eng., vol. 29, pp. 233-238, Apr. 1982.
    • (1982) IEEE Trans. Biomed. Eng. , vol.29 , pp. 233-238
    • White, R.L.1
  • 4
    • 0025359786 scopus 로고
    • Scaling limitations of silicon multichannel recording probes
    • Jan.
    • K. Najafi, J. Ji, and K. D. Wise, "Scaling limitations of silicon multichannel recording probes," IEEE Trans. Biomed. Eng., vol. 37, pp. 1-11, Jan. 1990.
    • (1990) IEEE Trans. Biomed. Eng. , vol.37 , pp. 1-11
    • Najafi, K.1    Ji, J.2    Wise, K.D.3
  • 5
    • 0028662508 scopus 로고
    • A three-dimensional microelectrode array for chronic neural recording
    • Dec.
    • A. C. Hoogerwerf and K. D. Wise, "A three-dimensional microelectrode array for chronic neural recording," IEEE Trans. Biomed. Eng., pp. 1136-1146, Dec. 1994.
    • (1994) IEEE Trans. Biomed. Eng. , pp. 1136-1146
    • Hoogerwerf, A.C.1    Wise, K.D.2
  • 6
    • 0028416752 scopus 로고
    • Silicon ribbon cables for chronically-implantable microelectrode arrays
    • Apr.
    • J. F. Hetke, J. L. Lund, K. Najafi, K. D. Wise, and D. J. Anderson, "Silicon ribbon cables for chronically-implantable microelectrode arrays," IEEE Trans. Biomed. Eng., vol. 41, pp. 314-321, Apr. 1994.
    • (1994) IEEE Trans. Biomed. Eng. , vol.41 , pp. 314-321
    • Hetke, J.F.1    Lund, J.L.2    Najafi, K.3    Wise, K.D.4    Anderson, D.J.5
  • 7
    • 0026966132 scopus 로고
    • A 16-Channel CMOS neural stimulating array
    • Dec.
    • S. J. Tanghe and K. D. Wise, "A 16-Channel CMOS neural stimulating array," IEEE J. Solid-State Circuits, vol. 27, pp. 1819-1825, Dec. 1992.
    • (1992) IEEE J. Solid-State Circuits , vol.27 , pp. 1819-1825
    • Tanghe, S.J.1    Wise, K.D.2
  • 8
    • 0242448152 scopus 로고
    • Multichannel neural probes with on-chip CMOS circuitry and high-current stimulating sites
    • Yokohama, Japan
    • C. Kim, S. J. Tanghe, and K. D. Wise, "Multichannel neural probes with on-chip CMOS circuitry and high-current stimulating sites," in Dig. Int. Conf. Solid-State Sensors and Actuators, Yokohama, Japan, 1993, pp. 454-457.
    • (1993) Dig. Int. Conf. Solid-State Sensors and Actuators , pp. 454-457
    • Kim, C.1    Tanghe, S.J.2    Wise, K.D.3
  • 9
    • 0004287207 scopus 로고
    • Chip-Level encapsulation of implantable CMOS microelectrode arrays
    • Hilton Head, SC, June
    • J. L. Lund and K. D. Wise, "Chip-Level encapsulation of implantable CMOS microelectrode arrays," in Dig. Solid-State Sensor and Actuator Workshop, Hilton Head, SC, June 1994, pp. 29-32.
    • (1994) Dig. Solid-State Sensor and Actuator Workshop , pp. 29-32
    • Lund, J.L.1    Wise, K.D.2
  • 10
    • 0016125157 scopus 로고
    • An evaluation of the resistance to electrolysis of metals for use in biostimulation microprobes
    • Nov.
    • R. L. White and T. J. Gross, "An evaluation of the resistance to electrolysis of metals for use in biostimulation microprobes," IEEE Trans. Biomed. Eng., pp. 487-490, Nov. 1974.
    • (1974) IEEE Trans. Biomed. Eng. , pp. 487-490
    • White, R.L.1    Gross, T.J.2
  • 11
    • 0024027087 scopus 로고
    • Charge injection limits of activated iridium oxide electrodes with 0.2 ms pulses in bicarbonate buffered saline
    • June
    • X. Beebe and T. L. Rose, "Charge injection limits of activated iridium oxide electrodes with 0.2 ms pulses in bicarbonate buffered saline," IEEE Trans. Biomed. Eng., vol. 35, pp. 494-495, June 1988.
    • (1988) IEEE Trans. Biomed. Eng. , vol.35 , pp. 494-495
    • Beebe, X.1    Rose, T.L.2
  • 12
    • 0026834706 scopus 로고
    • An implantable CMOS circuit interface for multiplexed microelectrode recording arrays
    • Mar.
    • J. Ji and K. D. Wise, "An implantable CMOS circuit interface for multiplexed microelectrode recording arrays," IEEE J. Solid-State Circuits, vol. 27, pp. 433-443, Mar. 1992.
    • (1992) IEEE J. Solid-State Circuits , vol.27 , pp. 433-443
    • Ji, J.1    Wise, K.D.2
  • 13
    • 0022285532 scopus 로고
    • A monolithic signal processor for a neurophysiological telemetry system
    • Dec.
    • M. G. Dorman, M. A. Prisbe, and J. D. Meindl, "A monolithic signal processor for a neurophysiological telemetry system," IEEE J. Solid-State Circuits, pp. 1185-1193, Dec. 1985.
    • (1985) IEEE J. Solid-State Circuits , pp. 1185-1193
    • Dorman, M.G.1    Prisbe, M.A.2    Meindl, J.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.