메뉴 건너뛰기




Volumn 25, Issue 5, 1996, Pages 397-406

Early experience with the use of an interlocking nail for the repair of canine femoral shaft fractures

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL; ANIMAL DISEASE; ARTICLE; BONE SCREW; DOG; EQUIPMENT DESIGN; FEMALE; FEMUR; FEMUR FRACTURE; INSTRUMENTATION; MALE; METHODOLOGY; PHYSIOLOGY; RADIOGRAPHY; STANDARD; TIME; VETERINARY MEDICINE; WOUND HEALING;

EID: 0030238280     PISSN: 01613499     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1532-950X.1996.tb01434.x     Document Type: Article
Times cited : (53)

References (31)
  • 1
    • 0023035665 scopus 로고
    • Interlocking nailing of complex fractures of the femur and tibia
    • Klemm KW, Börner M: Interlocking nailing of complex fractures of the femur and tibia. Clin Orthop 212:89-100, 1986
    • (1986) Clin Orthop , vol.212 , pp. 89-100
    • Klemm, K.W.1    Börner, M.2
  • 2
    • 0021690917 scopus 로고
    • Comminuted femoral-shaft fractures: Treatment by roller traction, cerclage wires and an intramedullary nail, or an interlocking intramedullary nail
    • Johnson KD, Johnston DW, Parker B: Comminuted femoral-shaft fractures: Treatment by roller traction, cerclage wires and an intramedullary nail, or an interlocking intramedullary nail. J Bone Joint Surg 66A:1222-1235, 1984
    • (1984) J Bone Joint Surg , vol.66 A , pp. 1222-1235
    • Johnson, K.D.1    Johnston, D.W.2    Parker, B.3
  • 3
    • 0024370577 scopus 로고
    • Technical considerations of the AO interlocking nail
    • Lowdon IM, Williamson DM, Nelson IW, et al: Technical considerations of the AO interlocking nail. Injury 20:222-225, 1989
    • (1989) Injury , vol.20 , pp. 222-225
    • Lowdon, I.M.1    Williamson, D.M.2    Nelson, I.W.3
  • 4
    • 0023745045 scopus 로고
    • Complex femur fractures: Treatment with the wagner external fixation device or the Grosse-Kempf interlocking nail
    • Murphy CP, D'ambrosia RD, Dabezeis EJ, et al: Complex femur fractures: Treatment with the wagner external fixation device or the Grosse-Kempf interlocking nail. J Trauma 28:1553-1561, 1988
    • (1988) J Trauma , vol.28 , pp. 1553-1561
    • Murphy, C.P.1    D'Ambrosia, R.D.2    Dabezeis, E.J.3
  • 5
    • 0026534173 scopus 로고
    • Femoral shaft fractures treated with plate fixation and interlocked nailing: A comparative retrospective study
    • van Niekerk JL, Schools FJ: Femoral shaft fractures treated with plate fixation and interlocked nailing: A comparative retrospective study. Injury 23:219-222, 1992
    • (1992) Injury , vol.23 , pp. 219-222
    • Van Niekerk, J.L.1    Schools, F.J.2
  • 7
    • 24344492505 scopus 로고
    • The intramedullary compression nail for difficult femoral fractures
    • Seligson D (ed): Orlando, FL, Grune & Stratton
    • Huckstep RL: The intramedullary compression nail for difficult femoral fractures, in Seligson D (ed): Concepts in Intramedullary Nailing. Orlando, FL, Grune & Stratton, 1985, pp 315-347
    • (1985) Concepts in Intramedullary Nailing , pp. 315-347
    • Huckstep, R.L.1
  • 8
    • 0023003320 scopus 로고
    • The Huckstep intramedullary compression nail. Indications, technique and results
    • Huckstep RL: The Huckstep intramedullary compression nail. Indications, technique and results. Clin Orthop 212:48-61, 1986
    • (1986) Clin Orthop , vol.212 , pp. 48-61
    • Huckstep, R.L.1
  • 10
    • 4043085659 scopus 로고
    • Bone remodelling in canine femora after internal fixation with the "Huckstep nail."
    • abstr
    • Johnson KA, Huckstep RL: Bone remodelling in canine femora after internal fixation with the "Huckstep nail." Vet Radiol 27:20, 1986 (abstr)
    • (1986) Vet Radiol , vol.27 , pp. 20
    • Johnson, K.A.1    Huckstep, R.L.2
  • 11
    • 0025138089 scopus 로고
    • Use of flexible intramedullary rods for fixation of femoral fractures in eight dogs
    • Church EM, Schrader SC: Use of flexible intramedullary rods for fixation of femoral fractures in eight dogs. J Am Vet Med Assoc 196:71-76, 1990
    • (1990) J Am Vet Med Assoc , vol.196 , pp. 71-76
    • Church, E.M.1    Schrader, S.C.2
  • 12
    • 0007319543 scopus 로고
    • Preliminary results: Biomechanical analysis of canine femora, solid intramedullary pins and interlocking medullary pins and interlocking medullary pins
    • abstr
    • Dueland RT, Berlund L, Schults F, et al: Preliminary results: Biomechanical analysis of canine femora, solid intramedullary pins and interlocking medullary pins and interlocking medullary pins. Vet Surg 20:334, 1991 (abstr)
    • (1991) Vet Surg , vol.20 , pp. 334
    • Dueland, R.T.1    Berlund, L.2    Schults, F.3
  • 13
    • 0007301978 scopus 로고
    • An experimental study of compression of femoral fractures by an interlocking intramedullary pin
    • Durall I, Diaz MC, Morales I: An experimental study of compression of femoral fractures by an interlocking intramedullary pin. Vet Comp Orthop Trauma 6:93-99, 1993
    • (1993) Vet Comp Orthop Trauma , vol.6 , pp. 93-99
    • Durall, I.1    Diaz, M.C.2    Morales, I.3
  • 14
    • 0000559073 scopus 로고
    • Interlocking nail fixation of diaphyseal fractures in the dog. a multi-center study of 1991-92 cases
    • abstr
    • Dueland RT, Johnson KA: Interlocking nail fixation of diaphyseal fractures in the dog. A multi-center study of 1991-92 cases. Vet Surg 22:377, 1993 (abstr)
    • (1993) Vet Surg , vol.22 , pp. 377
    • Dueland, R.T.1    Johnson, K.A.2
  • 15
    • 24344499188 scopus 로고
    • II chiodo blocatto de Grosse-Kempf nelle fratture diafisarie de femore nei piccoli animali: Prime experience cliniche
    • Vanozzi I, Carlucci F, Nesti S: II chiodo blocatto de Grosse-Kempf nelle fratture diafisarie de femore nei piccoli animali: Prime experience cliniche. Boll Assoc Ital Vet Pic Anim 3:53-60, 1991
    • (1991) Boll Assoc Ital Vet Pic Anim , vol.3 , pp. 53-60
    • Vanozzi, I.1    Carlucci, F.2    Nesti, S.3
  • 16
    • 0007186439 scopus 로고
    • Interlocking intramedullary nailing stabilization of a diaphyseal tibial fracture
    • Muir P, Parker RB, Goldsmid et al: Interlocking intramedullary nailing stabilization of a diaphyseal tibial fracture. J Small Anim Pract 34:26-30, 1993
    • (1993) J Small Anim Pract , vol.34 , pp. 26-30
    • Muir, P.1    Parker, R.B.2    Goldsmid3
  • 17
    • 0001597851 scopus 로고
    • L'enclouage verrouillé en chirurgie vétérinaire: De la concepcion aux premiers cas cliniques
    • Duhautois B: L'enclouage verrouillé en chirurgie vétérinaire: De la concepcion aux premiers cas cliniques. Prat Med Chir Anim Comp 28:657-683, 1993
    • (1993) Prat Med Chir Anim Comp , vol.28 , pp. 657-683
    • Duhautois, B.1
  • 18
    • 0007248312 scopus 로고
    • Interlocking nail stabilization of humeral fractures. Initial experience in seven clinical cases
    • Durall I, Diaz MC, Morales I: Interlocking nail stabilization of humeral fractures. Initial experience in seven clinical cases. Vet Comp Orthop Traum 7:3-8, 1994
    • (1994) Vet Comp Orthop Traum , vol.7 , pp. 3-8
    • Durall, I.1    Diaz, M.C.2    Morales, I.3
  • 21
    • 0026196989 scopus 로고
    • Complications associated with the use of Steinmann intramedullary pins and cerclage wires for fixation of long-bone fractures
    • Schrader SC: Complications associated with the use of Steinmann intramedullary pins and cerclage wires for fixation of long-bone fractures. Vet Clin North Am (Small Anim Pract) 21:687-704, 1991
    • (1991) Vet Clin North Am (Small Anim Pract) , vol.21 , pp. 687-704
    • Schrader, S.C.1
  • 22
    • 0026199533 scopus 로고
    • Complications of fractures repaired with plates and screws
    • Olmstead ML: Complications of fractures repaired with plates and screws. Vet Clin North Am (Small Anim Pract) 21:669-86, 1991
    • (1991) Vet Clin North Am (Small Anim Pract) , vol.21 , pp. 669-686
    • Olmstead, M.L.1
  • 23
    • 0025932992 scopus 로고
    • Mechanical characterization of femoral interlocking intramedullary nailing systems
    • Russell TA, Taylor JC, LaVelle DG, et al: Mechanical characterization of femoral interlocking intramedullary nailing systems. J Orthop Trauma 5:332-340, 1991
    • (1991) J Orthop Trauma , vol.5 , pp. 332-340
    • Russell, T.A.1    Taylor, J.C.2    LaVelle, D.G.3
  • 24
    • 0026687812 scopus 로고
    • Biomechanical analysis of the mechanism of interlocking nail failure
    • Wu C-C, Shih C-H: Biomechanical analysis of the mechanism of interlocking nail failure. Arch Orthop Trauma Surg 111:268-272, 1992
    • (1992) Arch Orthop Trauma Surg , vol.111 , pp. 268-272
    • Wu, C.-C.1    Shih, C.-H.2
  • 25
    • 0005175120 scopus 로고    scopus 로고
    • Methods of internal fracture fixation
    • Slatter DH (ed): Philadelphia, PA, Saunders
    • DeYoung DJ, Probst CW: Methods of internal fracture fixation, in Slatter DH (ed): Texbook of Small Animal Surgery. Philadelphia, PA, Saunders, 1985, pp 1949-1971
    • Texbook of Small Animal Surgery , vol.1985 , pp. 1949-1971
    • DeYoung, D.J.1    Probst, C.W.2
  • 27
    • 2542611757 scopus 로고
    • Internal fixation of femoral fractures
    • Bojrab MJ (ed): Philadelphia, PA Lea & Febiger
    • Gilmore DR: Internal fixation of femoral fractures, in Bojrab MJ (ed): Current Techniques in Small Animal Surgery. Philadelphia, PA Lea & Febiger, 1990, pp 387-470
    • (1990) Current Techniques in Small Animal Surgery , pp. 387-470
    • Gilmore, D.R.1
  • 29
    • 85033067854 scopus 로고
    • Principles of intramedullary pin and circumferential wire fixation
    • Munich
    • Schrader S: Principles of intramedullary pin and circumferential wire fixation. Semin Proceeding 3rd Vet Surg Forum. Munich, 1989, pp 35-39
    • (1989) Semin Proceeding 3rd Vet Surg Forum , pp. 35-39
    • Schrader, S.1
  • 30
    • 0025359675 scopus 로고
    • Lower infection rate after interlocking nailing in open fractures of femur and tibia
    • Kaltenecker G, Wruhs O, Quaicoe S: Lower infection rate after interlocking nailing in open fractures of femur and tibia. J Trauma 30:474-79, 1990
    • (1990) J Trauma , vol.30 , pp. 474-479
    • Kaltenecker, G.1    Wruhs, O.2    Quaicoe, S.3
  • 31
    • 85033049064 scopus 로고
    • Principles of intramedullary fixation
    • Chicago, IL
    • Schrader S: Principles of intramedullary fixation. Proceeding 16th Vet Surg Forum. Chicago, IL, 1988, pp 172-175
    • (1988) Proceeding 16th Vet Surg Forum , pp. 172-175
    • Schrader, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.