Volumn 3, Issue 9, 1996, Pages 735-741

Detection of simulated lung nodules with computed radiography: Effects of nodule size, local optical density, global object thickness, and exposure

Author keywords

Computed radiography; Exposure; Image quality; Lung nodule

Indexed keywords

METHACRYLIC ACID METHYL ESTER;

EID: 0030225741     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1076-6332(96)80412-0     Document Type: Article
Times cited : (9)

References (15)
  • 2
    • 0029111952 scopus 로고
    • Effects of reduced exposure on computed radiography: Comparison of nodule detection accuracy with conventional and asymmetric screen-film radiographs of a chest phantom
    • Kimme-Smith C, Aberle DR, Sayre JW, et al. Effects of reduced exposure on computed radiography: comparison of nodule detection accuracy with conventional and asymmetric screen-film radiographs of a chest phantom. AJR 1995;165:269-273.
    • (1995) AJR , vol.165 , pp. 269-273
    • Kimme-Smith, C.1    Aberle, D.R.2    Sayre, J.W.3
  • 3
    • 0026606935 scopus 로고
    • Threshold perception performance with computed and screen-film radiography: Implications for chest radiography
    • Dobbins JT, Rice JJ, Beam CA, Ravin CE. Threshold perception performance with computed and screen-film radiography: implications for chest radiography. Radiology 1992;183:179-187.
    • (1992) Radiology , vol.183 , pp. 179-187
    • Dobbins, J.T.1    Rice, J.J.2    Beam, C.A.3    Ravin, C.E.4
  • 4
    • 0024408750 scopus 로고
    • Improved control of image optical density with low dose digital and conventional radiography in bed-side imaging
    • Schaefer CM, Greene RE, Oestmann JW, et al. Improved control of image optical density with low dose digital and conventional radiography in bed-side imaging. Radiology 1989;173:713-716.
    • (1989) Radiology , vol.173 , pp. 713-716
    • Schaefer, C.M.1    Greene, R.E.2    Oestmann, J.W.3
  • 5
    • 0026738047 scopus 로고
    • Digital radiography with photostimulable storage phosphors: Control of detector latitude in chest imaging
    • Chotas HG, Ravin CE. Digital radiography with photostimulable storage phosphors: control of detector latitude in chest imaging. Invest Radiol 1992;27:822-828.
    • (1992) Invest Radiol , vol.27 , pp. 822-828
    • Chotas, H.G.1    Ravin, C.E.2
  • 6
    • 0023513057 scopus 로고
    • Effects of improved contrast on lung-nodule detection: A clinical ROC study
    • Sorenson JA, Mitchell CR, Armstrong JD, et al. Effects of improved contrast on lung-nodule detection: a clinical ROC study. Invest Radiol 1987; 22:772-780.
    • (1987) Invest Radiol , vol.22 , pp. 772-780
    • Sorenson, J.A.1    Mitchell, C.R.2    Armstrong, J.D.3
  • 7
    • 0022644797 scopus 로고
    • Digital and conventional chest imaging: A modified ROC study of observer performance using simulated nodules
    • Chakraborty DP, Breatnach ES, Yester MV, Soto B, Barnes GT, Fraser RG. Digital and conventional chest imaging: a modified ROC study of observer performance using simulated nodules. Radiology 1986;158:35-39.
    • (1986) Radiology , vol.158 , pp. 35-39
    • Chakraborty, D.P.1    Breatnach, E.S.2    Yester, M.V.3    Soto, B.4    Barnes, G.T.5    Fraser, R.G.6
  • 8
    • 0026513806 scopus 로고
    • Missed bronchogenic carcinoma: Radiographic findings in 27 patients with a potentially resectable lesion evident in retrospect
    • Austin JHM, Romney BM, Goldsmith LS. Missed bronchogenic carcinoma: radiographic findings in 27 patients with a potentially resectable lesion evident in retrospect. Radiology 1992;182:115-122.
    • (1992) Radiology , vol.182 , pp. 115-122
    • Austin, J.H.M.1    Romney, B.M.2    Goldsmith, L.S.3
  • 9
    • 0017120860 scopus 로고
    • Lesion conspicuity, structured noise, and film reader error
    • Kundel HL, Reves G. Lesion conspicuity, structured noise, and film reader error. AJR 1976;126:1233-1238.
    • (1976) AJR , vol.126 , pp. 1233-1238
    • Kundel, H.L.1    Reves, G.2
  • 11
    • 0028999842 scopus 로고
    • Comparison of receiver operating characteristic and forced choice observer performance measurement methods
    • Burgess AE. Comparison of receiver operating characteristic and forced choice observer performance measurement methods. Med Phys 1995; 22:643-655.
    • (1995) Med Phys , vol.22 , pp. 643-655
    • Burgess, A.E.1
  • 15
    • 0027396187 scopus 로고
    • Portable chest imaging: Comparison of storage phosphor digital, asymmetric screen-film, and conventional screen-film systems
    • Niklason LT, Chan HP, Cascade PN, Chang CL, Chee P, Mathews JF. Portable chest imaging: comparison of storage phosphor digital, asymmetric screen-film, and conventional screen-film systems. Radiology 1993;186:387-393.
    • (1993) Radiology , vol.186 , pp. 387-393
    • Niklason, L.T.1    Chan, H.P.2    Cascade, P.N.3    Chang, C.L.4    Chee, P.5    Mathews, J.F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.