메뉴 건너뛰기




Volumn 9, Issue 5-6, 1996, Pages 658-663

Biosensors in Flow-injection Systems for Biomedical Analysis, Process and Environmental Monitoring

Author keywords

Biomedical; Biosensor; Environmental monitoring; Flow injection analysis; Process monitoring

Indexed keywords

CARBARIL; DIMETHOATE; MALATHION; PARAOXON; PENICILLIN V; PESTICIDE; UREA;

EID: 0030224830     PISSN: 09523499     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1099-1352(199634/12)9:5/6<658::AID-JMR317>3.0.CO;2-M     Document Type: Article
Times cited : (11)

References (8)
  • 3
    • 0001141301 scopus 로고
    • Immobilization of thin enzyme membranes to construct glass enzyme electrodes
    • Kumaran, S., Meier, H., Danna, A.-M. and Tran-Minh, C. (1991). Immobilization of thin enzyme membranes to construct glass enzyme electrodes. Anal. Chem. 63, 1914-1918.
    • (1991) Anal. Chem. , vol.63 , pp. 1914-1918
    • Kumaran, S.1    Meier, H.2    Danna, A.-M.3    Tran-Minh, C.4
  • 4
    • 0025743746 scopus 로고
    • Rapid measurement of penicillin contained in complex mediums by enzyme loaded glass electrodes
    • Meier, H., Kumaran, S., Danna, A. M. and Tran-Minh, C. (1991). Rapid measurement of penicillin contained in complex mediums by enzyme loaded glass electrodes. Anal. Chim. Acta, 249, 405-411.
    • (1991) Anal. Chim. Acta , vol.249 , pp. 405-411
    • Meier, H.1    Kumaran, S.2    Danna, A.M.3    Tran-Minh, C.4
  • 6
    • 0015856218 scopus 로고
    • Determination of glucose urea and penicillin using enzyme-pH electrodes
    • Nilsson, H., Åkerlund, A. C. and Mosbach, K. (1973). Determination of glucose urea and penicillin using enzyme-pH electrodes. Biochim. Biophys. Acta 320, 529-534.
    • (1973) Biochim. Biophys. Acta , vol.320 , pp. 529-534
    • Nilsson, H.1    Åkerlund, A.C.2    Mosbach, K.3
  • 7
    • 0022716442 scopus 로고
    • New enzyme membrane for enzyme electrodes
    • Tor, R. and Freeman, A. (1986). New enzyme membrane for enzyme electrodes. Anal. Chem., 58, 1042-1046.
    • (1986) Anal. Chem. , vol.58 , pp. 1042-1046
    • Tor, R.1    Freeman, A.2
  • 8
    • 0017840615 scopus 로고
    • Réalisation et étude d'une électrode à acétylcholinestérase immobilisée pour le dosage de l'acétylcholine
    • Tran-Minh, C., Guyonnet, R. and Beaux, J. (1978). Réalisation et étude d'une électrode à acétylcholinestérase immobilisée pour le dosage de l'acétylcholine C. R. Acad. Sci. Paris, Ser. C, 286, 115-118.
    • (1978) C. R. Acad. Sci. Paris, Ser. C , vol.286 , pp. 115-118
    • Tran-Minh, C.1    Guyonnet, R.2    Beaux, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.