메뉴 건너뛰기




Volumn 44, Issue 9, 1996, Pages 602-605

'O' set connector system in CAPD

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; CHILD; CHRONIC KIDNEY FAILURE; CONTINUOUS AMBULATORY PERITONEAL DIALYSIS; ECONOMICS; EQUIPMENT; FEMALE; FOLLOW UP; HUMAN; INCIDENCE; INDIA; INSTRUMENTATION; MALE; MICROBIOLOGY; MIDDLE AGED; PERITONITIS; RETROSPECTIVE STUDY; TREATMENT OUTCOME;

EID: 0030224064     PISSN: 00045772     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (19)
  • 1
    • 0011370357 scopus 로고
    • Continuous ambulatory peritoneal dialysis
    • KD Nolph (Ed) 3rd Edn, Kluwer Academic Publishers
    • Moncrief JW, Popovich RP. Continuous ambulatory peritoneal dialysis. In : Peritoneal dialysis - KD Nolph (Ed) 3rd Edn, 1989. Kluwer Academic Publishers. P. 152-68.
    • (1989) Peritoneal Dialysis , pp. 152-168
    • Moncrief, J.W.1    Popovich, R.P.2
  • 2
    • 0003150859 scopus 로고
    • Peritonitis
    • Nolph KD (ed): Dordrecht, the Netherlands, Kluwer Academic
    • Vas SI. Peritonitis, in Nolph KD (ed): Peritoneal Dialysis (ed2). Dordrecht, the Netherlands, Kluwer Academic, 1989; p 261-88.
    • (1989) Peritoneal Dialysis (Ed2) , pp. 261-288
    • Vas, S.I.1
  • 3
    • 0027221038 scopus 로고
    • Continuous ambulatory peritoneal dialysis connection systems
    • Buoncristiani U. Continuous ambulatory peritoneal dialysis connection systems. Pent Dial Int 1993; 13 Suppl 2 : 139-45.
    • (1993) Pent Dial Int , vol.13 , Issue.2 SUPPL. , pp. 139-145
    • Buoncristiani, U.1
  • 4
    • 0020602957 scopus 로고
    • Autosterilizing CAPD connection sustems
    • Buoncristiani U, Dipaolo N. Autosterilizing CAPD connection sustems. Nephron. 1983; 35 : 244-47.
    • (1983) Nephron. , vol.35 , pp. 244-247
    • Buoncristiani, U.1    Dipaolo, N.2
  • 5
    • 0020613693 scopus 로고
    • Prospective controlled trial of a Y connector disinfectant to prevent peritonitis in continuous ambulatory peritoneal dialysis
    • Maiorca R, Cantaluppi A, Cancarinin GC. Brocolli R, Brase S. Prospective controlled trial of a Y connector disinfectant to prevent peritonitis in continuous ambulatory peritoneal dialysis. Lacet 1983; 2 : 642-44.
    • (1983) Lacet , vol.2 , pp. 642-644
    • Maiorca, R.1    Cantaluppi, A.2    Cancarinin, G.C.3    Brocolli, R.4    Brase, S.5
  • 6
    • 0024446797 scopus 로고
    • An in vitro study of the flush effect in two reusably CAPD disconnect system
    • Luzar MA, Slongeneyer A, Cantaluppi A, Paluso F. An in vitro study of the flush effect in two reusably CAPD disconnect system. Perit Dial Int 1989; 9 : 169-73.
    • (1989) Perit Dial Int , vol.9 , pp. 169-173
    • Luzar, M.A.1    Slongeneyer, A.2    Cantaluppi, A.3    Paluso, F.4
  • 7
    • 0026753494 scopus 로고
    • Risk of peritonitis and technique failure by CAPD connection technique : A national study
    • Port FK, Held PJ, Nolph KD, Turenne MN, Wolfe RA. Risk of peritonitis and technique failure by CAPD connection technique : A national study. Kidney Int 1992;42 : 967-74.
    • (1992) Kidney Int , vol.42 , pp. 967-974
    • Port, F.K.1    Held, P.J.2    Nolph, K.D.3    Turenne, M.N.4    Wolfe, R.A.5
  • 8
    • 1842587164 scopus 로고
    • Multicentre registry of patients using the 'O' set system for CAPD
    • Villano R. Multicentre registry of patients using the 'O' set system for CAPD. Adv CAPD 1988;4 : 304-7.
    • (1988) Adv CAPD , vol.4 , pp. 304-307
    • Villano, R.1
  • 9
    • 85047696258 scopus 로고
    • Chronic renal failure in India
    • MK Mani. Chronic renal failure in India. Nephrol Dial Transplant 1993; Vol. 8. no. 8 page 683.
    • (1993) Nephrol Dial Transplant , vol.8 , Issue.8 , pp. 683
    • Mani, M.K.1
  • 10
    • 0025326836 scopus 로고
    • Incidence of CAPD peritonitis in patients using UVXD or 'O' set systems
    • Bailie GR, Rasmussen R, Hollister A, et al : Incidence of CAPD peritonitis in patients using UVXD or 'O' set systems. Clin Nephrol 1990; 33 : 252-54.
    • (1990) Clin Nephrol , vol.33 , pp. 252-254
    • Bailie, G.R.1    Rasmussen, R.2    Hollister, A.3
  • 11
    • 0022756832 scopus 로고
    • A multicenter trial to evaluate the use of the CAPD 'O' set
    • Lempert KD, Kolb JA, Swartz RD, et al : A multicenter trial to evaluate the use of the CAPD 'O' set. ASAIO Trans 1986; 32 : 557-59.
    • (1986) ASAIO Trans , vol.32 , pp. 557-559
    • Lempert, K.D.1    Kolb, J.A.2    Swartz, R.D.3
  • 12
    • 0024427466 scopus 로고
    • Disconnect during continuous ambulatory peritoneal dialysis (CAPD) : Retrospective experience with three different systems
    • Swartz R, Reynolds J, Lees P, et al : Disconnect during continuous ambulatory peritoneal dialysis (CAPD) : Retrospective experience with three different systems. Perit Dial Int 1989; 9: 175-78.
    • (1989) Perit Dial Int , vol.9 , pp. 175-178
    • Swartz, R.1    Reynolds, J.2    Lees, P.3
  • 14
    • 0024459517 scopus 로고
    • Canadian CAPD peritoneal dialysis (CAPD). A multicentered randomized clinical trial comparing the Y connector disinfecrant system to standard systems
    • Churchill DN, Taylor DW, Vas SI, et al : Canadian CAPD peritoneal dialysis (CAPD). A multicentered randomized clinical trial comparing the Y connector disinfecrant system to standard systems. Perit Dial Int 1989:9 : 159-63.
    • (1989) Perit Dial Int , vol.9 , pp. 159-163
    • Churchill, D.N.1    Taylor, D.W.2    Vas, S.I.3
  • 15
    • 0024428364 scopus 로고
    • Prospected randomized study of two Y devices in continuous ambulatory peritoneal dialysis (CAPD)
    • Viglino G, Colomba A, et al : Prospected randomized study of two Y devices in continuous ambulatory peritoneal dialysis (CAPD). Perit Dial Int 1989; 9 : 165-68.
    • (1989) Perit Dial Int , vol.9 , pp. 165-168
    • Viglino, G.1    Colomba, A.2
  • 16
    • 2842514234 scopus 로고
    • Efficacy of CAPD Y-line systems without disinfectant and standard systems on peritonitis prevention : A multicentre prospective controlled trial abstract of the VIII Annual CAPD conference
    • abstract 165
    • Verger C, Faller B, Ryckelynk J-PH, et al : Efficacy of CAPD Y-line systems without disinfectant and standard systems on peritonitis prevention : A multicentre prospective controlled trial abstract of the VIII Annual CAPD conference. Perit Dial Int 1988 (abstract 165).
    • (1988) Perit Dial Int
    • Verger, C.1    Faller, B.2    Ryckelynk, J.-P.H.3
  • 17
    • 0027349386 scopus 로고
    • Higher incidence of catheter related infections in a tropical climate
    • Alves FR, Dantas RC, Lugon JR. Higher incidence of catheter related infections in a tropical climate. Adv Perit Dial 1993; 9 : 244-7.
    • (1993) Adv Perit Dial , vol.9 , pp. 244-247
    • Alves, F.R.1    Dantas, R.C.2    Lugon, J.R.3
  • 18
    • 0006341204 scopus 로고
    • Prospective randomized study about Y connectors in CAPD patients
    • in khanna R, Nolph KD,. Prowant B, et al (eds) : Toronto, Canada Peritoneal Dialysis Bulletin
    • Rottenbourg J, Brouard R, Issad B, et al : Prospective randomized study about Y connectors in CAPD patients, in khanna R, Nolph KD,. Prowant B, et al (eds) : Advances in Continuous Ambulatory Peritoneal Dialysis. Toronto, Canada Peritoneal Dialysis Bulletin , 1987; pp 107-113.
    • (1987) Advances in Continuous Ambulatory Peritoneal Dialysis , pp. 107-113
    • Rottenbourg, J.1    Brouard, R.2    Issad, B.3
  • 19
    • 0020613693 scopus 로고
    • Prospective controlled trial of a Y connector and disinfectant to prevent peritonitis in continuous ambulatory peritoneal dialysis
    • Majorca R, Cantaluppi A, Canarinin GC et al. Prospective controlled trial of a Y connector and disinfectant to prevent peritonitis in continuous ambulatory peritoneal dialysis. Lancet 1993; 2 : 642-44.
    • (1993) Lancet , vol.2 , pp. 642-644
    • Majorca, R.1    Cantaluppi, A.2    Canarinin, G.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.