Volumn 19, Issue 3, 1996, Pages 131-150

Modelling clinical accelerator beams: A review

Author keywords

Beam modelling; Linear accelerators; Review

Indexed keywords

ALGORITHM; BIOPHYSICS; COMPUTER ASSISTED RADIOTHERAPY; ELECTRON; HUMAN; MAGNETIC AND ELECTROMAGNETIC EQUIPMENT; METHODOLOGY; MONTE CARLO METHOD; REVIEW; STATISTICS; THEORETICAL MODEL;

EID: 0030222480     PISSN: 01589938     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (10)
  • 1
    • 0003639056 scopus 로고
    • Determination of Absorbed Dose in a Patient Irradiated by Beams of X or Gamma Rays in Radiotherapy Procedures
    • Washington, D.C.: ICRU
    • ICRU, Determination of Absorbed Dose in a Patient Irradiated by Beams of X or Gamma Rays in Radiotherapy Procedures, ICRU Report 24, Washington, D.C.: ICRU, 1976.
    • (1976) ICRU Report , vol.24
  • 2
    • 0023867479 scopus 로고
    • Effects of dosimetric and clinical unceratainty on complication-free local tumour control
    • Boyer, A.L. and Schulteiss, T., Effects of dosimetric and clinical unceratainty on complication-free local tumour control, Radiotherapy & Oncology. 11: 65-71, 1988.
    • (1988) Radiotherapy & Oncology , vol.11 , pp. 65-71
    • Boyer, A.L.1    Schulteiss, T.2
  • 3
    • 0028265490 scopus 로고
    • Optimization of radiation therapy
    • Brahme, A., Optimization of radiation therapy, Int. J. Rad. Oncol. Biol. Phys. 28: 785-786, 1994.
    • (1994) Int. J. Rad. Oncol. Biol. Phys. , vol.28 , pp. 785-786
    • Brahme, A.1
  • 5
    • 0022631089 scopus 로고
    • Differential pencil beam computation model for photons
    • Mohan, R. and Chui, C., Differential pencil beam computation model for photons, Med. Phys. 13: 64-73, 1985.
    • (1985) Med. Phys. , vol.13 , pp. 64-73
    • Mohan, R.1    Chui, C.2
  • 6
    • 0026565958 scopus 로고
    • A macro Monte Carlo method for electron beam dose caclulations
    • Neuenschwander, H. and Born, E.R., A macro Monte Carlo method for electron beam dose caclulations, Phys. Med. Biol. 37: 107-125, 1992.
    • (1992) Phys. Med. Biol. , vol.37 , pp. 107-125
    • Neuenschwander, H.1    Born, E.R.2
  • 7
    • 0028953755 scopus 로고
    • MMC - A high-performance Monte Carlo code for electron beam treatment planning
    • Neuenschwander, H., Mackie, T.R. and Reckwerdt, P.J., MMC - A high-performance Monte Carlo code for electron beam treatment planning, Phys. Med. Biol. 40: 543-574, 1995.
    • (1995) Phys. Med. Biol. , vol.40 , pp. 543-574
    • Neuenschwander, H.1    Mackie, T.R.2    Reckwerdt, P.J.3
  • 8
    • 0022030535 scopus 로고
    • Comparison of three dimensional Monte Carlo simulation and the pencil beam algorithm for an electron beam from a linear accelerator
    • Manfredotti, C., Nastasi, U., Ragona, R. & Anglesio, S., Comparison of three dimensional Monte Carlo simulation and the pencil beam algorithm for an electron beam from a linear accelerator, Nucl. Instr. Meth. Phys. Res. A255: 355-359, 1987.
    • (1987) Nucl. Instr. Meth. Phys. Res. , vol.A255 , pp. 355-359
    • Manfredotti, C.1    Nastasi, U.2    Ragona, R.3    Anglesio, S.4
  • 9
    • 0024452070 scopus 로고
    • Numerical calculation of energy deposition for broad high-energy electron beams
    • Huizenga, H. and Storchi, P.R.M., Numerical calculation of energy deposition for broad high-energy electron beams, Phys. Med. Biol. 34: 1371-1396, 1989.
    • (1989) Phys. Med. Biol. , vol.34 , pp. 1371-1396
    • Huizenga, H.1    Storchi, P.R.M.2
  • 10
    • 0026641469 scopus 로고
    • Numerical calculation of energy deposition by broad high-energy electron beams: II. Multilayered geometry
    • Morawska-Kaczynska, M. and Huizenga, H., Numerical calculation of energy deposition by broad high-energy electron beams: II. Multilayered geometry, Phys. Med. Biol. 37: 2103-2116, 1992.
    • (1992) Phys. Med. Biol. , vol.37 , pp. 2103-2116
    • Morawska-Kaczynska, M.1    Huizenga, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.