메뉴 건너뛰기




Volumn 12, Issue 2, 1996, Pages 283-302

Instrumentation and Techniques in Equine Fracture Fixation

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL; ANIMAL DISEASE; FRACTURE; HORSE; INJURY; METHODOLOGY; ORTHOPEDIC EQUIPMENT; ORTHOPEDICS; REVIEW; VETERINARY MEDICINE;

EID: 0030207441     PISSN: 07490739     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0749-0739(17)30283-3     Document Type: Article
Times cited : (16)

References (40)
  • 1
    • 0000979936 scopus 로고
    • Primary treatment of severe fractures by external skeletal fixation: Threaded pins compared with smooth
    • Aaron, D.N., Toombs, J.P., Hollingsworth, S.C., Primary treatment of severe fractures by external skeletal fixation: Threaded pins compared with smooth. J Am Anim Hosp Assoc 22 (1986), 659–670.
    • (1986) J Am Anim Hosp Assoc , vol.22 , pp. 659-670
    • Aaron, D.N.1    Toombs, J.P.2    Hollingsworth, S.C.3
  • 2
    • 0039785911 scopus 로고
    • Application of the dynamic condylar screw (DCS) dynamic hip screw (DHS) implant system in the horse
    • Auer, J.A., Application of the dynamic condylar screw (DCS) dynamic hip screw (DHS) implant system in the horse. Veterinary Comparative Orthopedics Trauma 1 (1988), 18–25.
    • (1988) Veterinary Comparative Orthopedics Trauma , vol.1 , pp. 18-25
    • Auer, J.A.1
  • 3
    • 0038517263 scopus 로고
    • Principles in fracture treatment
    • Auer J.A. WB Saunders Philadelphia, PA
    • Auer, J.A., Principles in fracture treatment. Auer, J.A., (eds.) Equine Surgery, 1992, WB Saunders, Philadelphia, PA, 812–833.
    • (1992) Equine Surgery , pp. 812-833
    • Auer, J.A.1
  • 4
    • 85027246890 scopus 로고
    • The pinless fixateur externe: An interesting new device [abstract]
    • Auer, J.A., Frigg, R., The pinless fixateur externe: An interesting new device [abstract]. Vet Surg, 23, 1994, 213.
    • (1994) Vet Surg , vol.23 , pp. 213
    • Auer, J.A.1    Frigg, R.2
  • 5
    • 85027274329 scopus 로고
    • Dynamic condylar screw and dynamic hip screw application
    • Nixon A.J. WB Saunders Philadelphia
    • Auer, J.A., Dynamic condylar screw and dynamic hip screw application. Nixon, A.J., (eds.) Equine Fracture Repair, 1995, WB Saunders, Philadelphia, 71–73.
    • (1995) Equine Fracture Repair , pp. 71-73
    • Auer, J.A.1
  • 6
    • 0028827666 scopus 로고
    • Application of the point contact fixator in large animals
    • Auer, J.A., Lischer, C., Kaegi, B., et al. Application of the point contact fixator in large animals. Injury 26:suppl 2 (1995), SB37–SB46.
    • (1995) Injury , vol.26 , pp. SB37-SB46
    • Auer, J.A.1    Lischer, C.2    Kaegi, B.3
  • 7
    • 0039276556 scopus 로고
    • Surgical Equipment and Implants for Fracture Repair
    • Nixon A.J. WB Saunders Philadelphia
    • Auer, J.A., Surgical Equipment and Implants for Fracture Repair. Nixon, A.J., (eds.) Equine Fracture Repair, 1995, WB Saunders, Philadelphia, 52–62.
    • (1995) Equine Fracture Repair , pp. 52-62
    • Auer, J.A.1
  • 8
    • 0027714916 scopus 로고
    • AO/ASIF Selftapping screws (STS)
    • Baumgart, F.W., Cordey, J., Morikawa, K., et al. AO/ASIF Selftapping screws (STS). Injury 24:suppl 1 (1995), S1–S17.
    • (1995) Injury , vol.24 , pp. S1-S17
    • Baumgart, F.W.1    Cordey, J.2    Morikawa, K.3
  • 9
    • 0025141917 scopus 로고
    • A comparison of the mechanical properties of fiberglass cast materials and their clinical relevance
    • Berman, A.T., Parks, B.G., A comparison of the mechanical properties of fiberglass cast materials and their clinical relevance. J Orthop Trauma 14 (1990), 85–92.
    • (1990) J Orthop Trauma , vol.14 , pp. 85-92
    • Berman, A.T.1    Parks, B.G.2
  • 10
    • 0141882743 scopus 로고
    • Resin-impregnated foam as a cast liner on the distal equine limb
    • In Proceedings of the American Association of Equine Practitioners
    • Bramlage LR, Embertson RM, Libby CJ: Resin-impregnated foam as a cast liner on the distal equine limb. In Proceedings of the American Association of Equine Practitioners, 1991, pp 481–485.
    • (1991) , pp. 481-485
    • Bramlage, L.R.1    Embertson, R.M.2    Libby, C.J.3
  • 11
    • 0029446970 scopus 로고
    • Double-plate fixation of comminuted fractures of the second phalanx in horses: 10 cases (1985-1993)
    • Crabill, M.R., Watkins, J.P., Schneider, R.K., et al. Double-plate fixation of comminuted fractures of the second phalanx in horses: 10 cases (1985-1993). J Am Vet Med Assoc 207 (1995), 1358–1461.
    • (1995) J Am Vet Med Assoc , vol.207 , pp. 1358-1461
    • Crabill, M.R.1    Watkins, J.P.2    Schneider, R.K.3
  • 12
    • 0025514223 scopus 로고
    • Torsional strength reduction due to cortical defects in bone
    • Edgerton, B.C., An, K.N., Morrey, B.F., Torsional strength reduction due to cortical defects in bone. J Orthop Res 88 (1990), 851–855.
    • (1990) J Orthop Res , vol.88 , pp. 851-855
    • Edgerton, B.C.1    An, K.N.2    Morrey, B.F.3
  • 13
    • 0039247774 scopus 로고
    • Equine osteosynthesis: An electronic manual of the AO/ASIF technique
    • Synthes-AO/ASIF Foundation Paoli, PA
    • Fackelman, G.E., Nunamaker, D.M., Auer, J.A., Equine osteosynthesis: An electronic manual of the AO/ASIF technique. 1994, Synthes-AO/ASIF Foundation, Paoli, PA.
    • (1994)
    • Fackelman, G.E.1    Nunamaker, D.M.2    Auer, J.A.3
  • 14
    • 0039276551 scopus 로고
    • Proximal radius fracture in a horse: Angle blade plate repair
    • Frauenfelder, H.C., Fessler, J.F., Proximal radius fracture in a horse: Angle blade plate repair. Vet Surg 10 (1979), 96–100.
    • (1979) Vet Surg , vol.10 , pp. 96-100
    • Frauenfelder, H.C.1    Fessler, J.F.2
  • 15
    • 0025022052 scopus 로고
    • Femoral capital physeal fractures in 25 foals
    • Hunt, D.A., Snyder, J.R., Morgan, J.P., et al. Femoral capital physeal fractures in 25 foals. Vet Surg 19 (1990), 41–49.
    • (1990) Vet Surg , vol.19 , pp. 41-49
    • Hunt, D.A.1    Snyder, J.R.2    Morgan, J.P.3
  • 16
    • 0024660565 scopus 로고
    • Use of the cobra head bone plate for distal long bone fractures in large animals: A report of four cases
    • Kirker-Head, C.A., Facdelman, G.E., Use of the cobra head bone plate for distal long bone fractures in large animals: A report of four cases. Vet Surg 18 (1989), 227–234.
    • (1989) Vet Surg , vol.18 , pp. 227-234
    • Kirker-Head, C.A.1    Facdelman, G.E.2
  • 17
    • 85027255919 scopus 로고    scopus 로고
    • Pinless external fixation of mandible fractures in cattle
    • Vet Surg, submitted
    • Lischer CJ, Fluri E, Auer JA: Pinless external fixation of mandible fractures in cattle. Vet Surg, submitted.
    • Lischer, C.J.1    Fluri, E.2    Auer, J.A.3
  • 18
    • 0028507185 scopus 로고
    • In vitro comparison of the standard short limb cast and three configurations of short limb transfixation casts in equine forelimbs
    • McClure, S.R., Watkins, J.P., Bronson, D.G., et al. In vitro comparison of the standard short limb cast and three configurations of short limb transfixation casts in equine forelimbs. Am J Vet Res 55 (1994), 1331–1334.
    • (1994) Am J Vet Res , vol.55 , pp. 1331-1334
    • McClure, S.R.1    Watkins, J.P.2    Bronson, D.G.3
  • 19
    • 0028511451 scopus 로고
    • In vitro comparison of the effect of parallel and divergent transfixation pins on breaking strength of equine third metacarpal bones
    • McClure, S.R., Watkins, J.P., Ashman, R.B., In vitro comparison of the effect of parallel and divergent transfixation pins on breaking strength of equine third metacarpal bones. Am J Vet Res 55 (1994), 1327–1330.
    • (1994) Am J Vet Res , vol.55 , pp. 1327-1330
    • McClure, S.R.1    Watkins, J.P.2    Ashman, R.B.3
  • 21
    • 0028470096 scopus 로고
    • An in vitro biomechanical investigation of an interlocking nail for fixation of diaphyseal tibial fractures in adult horses
    • McDuffee, L.A., Stover, S.M., Taylor, K.M., et al. An in vitro biomechanical investigation of an interlocking nail for fixation of diaphyseal tibial fractures in adult horses. Vet Surg 23 (1994), 219–230.
    • (1994) Vet Surg , vol.23 , pp. 219-230
    • McDuffee, L.A.1    Stover, S.M.2    Taylor, K.M.3
  • 22
    • 0027022524 scopus 로고
    • Biomechanical evaluation of the pinless external fixator
    • Moe Stene, G., Frigg, R., Schlegel, U., et al. Biomechanical evaluation of the pinless external fixator. Injury 23:suppl 3 (1992), S9–S28.
    • (1992) Injury , vol.23 , pp. S9-S28
    • Moe Stene, G.1    Frigg, R.2    Schlegel, U.3
  • 23
    • 0026060172 scopus 로고
    • The use of the walking cast to repair fractures in horses and ponies
    • Nemeth, F., Back, W., The use of the walking cast to repair fractures in horses and ponies. Equine Vet J 23 (1991), 32–36.
    • (1991) Equine Vet J , vol.23 , pp. 32-36
    • Nemeth, F.1    Back, W.2
  • 24
    • 84995159433 scopus 로고
    • A new external skeletal fixation device that allows immediate full weight-bearing: Application in the horse
    • Nunamaker, D.M., Richardson, D.W., Butterweck, D.M., et al. A new external skeletal fixation device that allows immediate full weight-bearing: Application in the horse. Vet Surg 15 (1986), 345–355.
    • (1986) Vet Surg , vol.15 , pp. 345-355
    • Nunamaker, D.M.1    Richardson, D.W.2    Butterweck, D.M.3
  • 25
    • 84995159403 scopus 로고
    • Plate luting: A preliminary report of its use in horses
    • Nunamaker, D.M., Bowman, K.F., Richardson, D.W., et al. Plate luting: A preliminary report of its use in horses. Vet Surg 15 (1986), 289–293.
    • (1986) Vet Surg , vol.15 , pp. 289-293
    • Nunamaker, D.M.1    Bowman, K.F.2    Richardson, D.W.3
  • 26
    • 0026450440 scopus 로고
    • Principles of bone healing and biomechanics of external skeletal fixation
    • Palmer, R.H., Hulse, D.A., Hyman, W.A., et al. Principles of bone healing and biomechanics of external skeletal fixation. Vet Clin North Am Small Anim Pract 22 (1992), 45–68.
    • (1992) Vet Clin North Am Small Anim Pract , vol.22 , pp. 45-68
    • Palmer, R.H.1    Hulse, D.A.2    Hyman, W.A.3
  • 27
    • 0029203996 scopus 로고
    • Stress protection afforded by a cast on plate fixation of the distal forelimb in the horse in vitro
    • Parente, E.J., Nunamaker, D.M., Stress protection afforded by a cast on plate fixation of the distal forelimb in the horse in vitro. Vet Surg 24 (1995), 49–54.
    • (1995) Vet Surg , vol.24 , pp. 49-54
    • Parente, E.J.1    Nunamaker, D.M.2
  • 28
    • 0026229254 scopus 로고
    • Evaluation of plate luting, using an in vivo ovine osteotomy model
    • Richardson, D.W., Nunamaker, D.M., Evaluation of plate luting, using an in vivo ovine osteotomy model. Am J Vet Res 52 (1991), 1468–1473.
    • (1991) Am J Vet Res , vol.52 , pp. 1468-1473
    • Richardson, D.W.1    Nunamaker, D.M.2
  • 29
    • 0028885139 scopus 로고
    • Clinical handling: Small animals
    • Savoldelli, D., Montavon, P.M., Clinical handling: Small animals. Injury 26:suppl 2 (1995), SB47–SB50.
    • (1995) Injury , vol.26 , pp. SB47-SB50
    • Savoldelli, D.1    Montavon, P.M.2
  • 30
    • 0028810294 scopus 로고
    • Changes in the AO/ASIF principles and methods
    • Schatzker, J., Changes in the AO/ASIF principles and methods. Injury 26:suppl 2 (1995), SB51–SB56.
    • (1995) Injury , vol.26 , pp. SB51-SB56
    • Schatzker, J.1
  • 31
    • 85027266334 scopus 로고
    • the AO/ASIF self-tapping screw (STS). In Proceedings of the American College of Veterinary Surgeons Symposium, Large Animal, Chicago, 5:231
    • Schnewlin M, Auer JA: the AO/ASIF self-tapping screw (STS). In Proceedings of the American College of Veterinary Surgeons Symposium, Large Animal, Chicago, 5:231, 1995.
    • (1995)
    • Schnewlin, M.1    Auer, J.A.2
  • 32
    • 0021678609 scopus 로고
    • A biomechanical comparison of various methods of stabilization of subtrochanteric fractures of the femur
    • Tencer, A.F., Johnson, K.D., Johnston, W.C., et al. A biomechanical comparison of various methods of stabilization of subtrochanteric fractures of the femur. J Orthop Res 2 (1984), 297–305.
    • (1984) J Orthop Res , vol.2 , pp. 297-305
    • Tencer, A.F.1    Johnson, K.D.2    Johnston, W.C.3
  • 33
    • 0029875425 scopus 로고    scopus 로고
    • Use of antimicrobial-impregnated polymethyl methacrylate
    • Tobias, K.M.S., Schneider, R.K., Besser, T.E., Use of antimicrobial-impregnated polymethyl methacrylate. J Am Vet Med Assoc 208 (1996), 841–845.
    • (1996) J Am Vet Med Assoc , vol.208 , pp. 841-845
    • Tobias, K.M.S.1    Schneider, R.K.2    Besser, T.E.3
  • 35
    • 0041026302 scopus 로고
    • Intramedullary interlocking nail fixation in transverse humeral fractures: An in vitro comparison with stacked pin fixation
    • In Proceedings of the Veterinary Orthopedic Society
    • Watkins JP, Ashman RB: Intramedullary interlocking nail fixation in transverse humeral fractures: An in vitro comparison with stacked pin fixation. In Proceedings of the Veterinary Orthopedic Society, 1991, p 54.
    • (1991) , pp. 54
    • Watkins, J.P.1    Ashman, R.B.2
  • 36
    • 0040432328 scopus 로고
    • Intramedullary interlocking nail fixation in foals: Effects on normal growth and development of the humerus [abstract]
    • Watkins, J.P., Ashman, R.B., Intramedullary interlocking nail fixation in foals: Effects on normal growth and development of the humerus [abstract]. Vet Surg, 19, 1990, 80.
    • (1990) Vet Surg , vol.19 , pp. 80
    • Watkins, J.P.1    Ashman, R.B.2
  • 37
    • 0026195219 scopus 로고
    • Fixation of femoral capital physeal fractures with 7.0 mm cannulated screws in five bulls
    • Wilson, D.G., Crawford, W.H., Stone, W.C., et al. Fixation of femoral capital physeal fractures with 7.0 mm cannulated screws in five bulls. Vet Surg 20 (1991), 240–244.
    • (1991) Vet Surg , vol.20 , pp. 240-244
    • Wilson, D.G.1    Crawford, W.H.2    Stone, W.C.3
  • 39
    • 0029181449 scopus 로고
    • An evaluation of six synthetic casting materials: Strength of cylinders in bending
    • Wilson, D.G., Vanderby, R., An evaluation of six synthetic casting materials: Strength of cylinders in bending. Vet Surg 24 (1995), 55–59.
    • (1995) Vet Surg , vol.24 , pp. 55-59
    • Wilson, D.G.1    Vanderby, R.2
  • 40
    • 0029266520 scopus 로고
    • An evaluation of fiberglass cast application techniques
    • Wilson, D.G., Vanderby, R., An evaluation of fiberglass cast application techniques. Vet Surg 24 (1995), 118–121.
    • (1995) Vet Surg , vol.24 , pp. 118-121
    • Wilson, D.G.1    Vanderby, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.