-
1
-
-
0020831434
-
Operation of chemically sensitive field-effect sensors as a function of the insulator-electrolyte interface
-
L.J. Bousse, N.F. de Rooij and P. Bergveld, Operation of chemically sensitive field-effect sensors as a function of the insulator-electrolyte interface, IEEE Trans. Electron Devices, ED-30, 10 (1983) 1263-1270.
-
(1983)
IEEE Trans. Electron Devices
, vol.10 ED-30
, pp. 1263-1270
-
-
Bousse, L.J.1
De Rooij, N.F.2
Bergveld, P.3
-
2
-
-
37049137333
-
Site-binding model of the electrical double layer at the oxide/water interface
-
D.E. Yates, S. Levine and T.W. Healy, Site-binding model of the electrical double layer at the oxide/water interface, J. Chem. Soc. Faraday Trans., 70 (1974) 1807-1818.
-
(1974)
J. Chem. Soc. Faraday Trans.
, vol.70
, pp. 1807-1818
-
-
Yates, D.E.1
Levine, S.2
Healy, T.W.3
-
3
-
-
0029277393
-
A novel description of ISFET sensitivity with the buffer capacity and double-layer capacitance as key parameters
-
R.E.G. van Hal, J.C.T. Eijkel and P. Bergveld, A novel description of ISFET sensitivity with the buffer capacity and double-layer capacitance as key parameters, Sensors and Actuators B, 24-25 (1995) 201-205.
-
(1995)
Sensors and Actuators B
, vol.24-25
, pp. 201-205
-
-
Van Hal, R.E.G.1
Eijkel, J.C.T.2
Bergveld, P.3
-
4
-
-
0011730584
-
Sensing developments using ISFETs
-
I. Robins, Sensing developments using ISFETs, International LABMATE (1993) 45-46.
-
(1993)
International LABMATE
, pp. 45-46
-
-
Robins, I.1
-
5
-
-
0028070334
-
Micromachined analyzers on a silicon chip
-
P. Arquint, M. Koudelka-Hep, B.H. van der Shoot, P. van der Wal and N.F. de Rooij, Micromachined analyzers on a silicon chip, Clin. Chem., 40 (1994) 1805-1809.
-
(1994)
Clin. Chem.
, vol.40
, pp. 1805-1809
-
-
Arquint, P.1
Koudelka-Hep, M.2
Van Der Shoot, B.H.3
Van Der Wal, P.4
De Rooij, N.F.5
-
6
-
-
0025245205
-
On line blood electrolyte monitoring with a ChemFET microcell system
-
W. Gumbrecht, W. Schelter and B. Montag, On line blood electrolyte monitoring with a ChemFET microcell system, Sensors and Actuators, B1 (1990) 477-488.
-
(1990)
Sensors and Actuators
, vol.B1
, pp. 477-488
-
-
Gumbrecht, W.1
Schelter, W.2
Montag, B.3
-
7
-
-
0027255920
-
Analytical evaluation of i-STAT portable clinical analyzer and use by non-laboratory healthcare professionals
-
E. Jacobs, E. Vadasdi, L. Sarkozi and N. Colman, Analytical evaluation of i-STAT portable clinical analyzer and use by non-laboratory healthcare professionals, Clin. Chem., 39 (1993) 1069-1074.
-
(1993)
Clin. Chem.
, vol.39
, pp. 1069-1074
-
-
Jacobs, E.1
Vadasdi, E.2
Sarkozi, L.3
Colman, N.4
-
8
-
-
0010883957
-
Integrated coulometric sensor-actuator devices
-
W. Olthuis and P. Bergveld, Integrated coulometric sensor-actuator devices, Microchimica Acta, 121 (1995) 191-223.
-
(1995)
Microchimica Acta
, vol.121
, pp. 191-223
-
-
Olthuis, W.1
Bergveld, P.2
-
9
-
-
0026208888
-
Iridium oxide as actuator material for the ISFET-based sensor-actuator system
-
W. Olthuis, J.G. Borner, P. Bergveld, M. Bos and W.E. van der Linden, Iridium oxide as actuator material for the ISFET-based sensor-actuator system, Sensors and Actuators B, 5 (1991) 47-52.
-
(1991)
Sensors and Actuators B
, vol.5
, pp. 47-52
-
-
Olthuis, W.1
Borner, J.G.2
Bergveld, P.3
Bos, M.4
Van Der Linden, W.E.5
-
10
-
-
0026034882
-
A critical evaluation of direct electrical protein detection methods
-
P. Bergveld, A critical evaluation of direct electrical protein detection methods, Biosensors Bioelectron., 6 (1991) 55-72.
-
(1991)
Biosensors Bioelectron.
, vol.6
, pp. 55-72
-
-
Bergveld, P.1
-
11
-
-
0029256549
-
The ISFET-based heparin sensor with a monolayer of protamine as affinity ligand
-
J.C. van Kerkhof, P. Bergveld and R.B.M. Schasfoort, The ISFET-based heparin sensor with a monolayer of protamine as affinity ligand, Biosensors Bioelectron., 10 (1995) 269-282.
-
(1995)
Biosensors Bioelectron.
, vol.10
, pp. 269-282
-
-
Van Kerkhof, J.C.1
Bergveld, P.2
Schasfoort, R.B.M.3
-
12
-
-
0027764611
-
Development of an ISFET-based heparin sensor using the ion-step measuring method
-
J.C. van Kerkhof, P. Bergveld and R.B.M. Schasfoort, Development of an ISFET-based heparin sensor using the ion-step measuring method, Biosensors Bioelectron., 8 (1993) 463-472.
-
(1993)
Biosensors Bioelectron.
, vol.8
, pp. 463-472
-
-
Van Kerkhof, J.C.1
Bergveld, P.2
Schasfoort, R.B.M.3
-
13
-
-
0025229080
-
Competitive immunological detection of progesterone by means of the ion-step induced response of an immunoFET
-
R.B.M. Schasfoort, C.E.J.M. Keldermans, R.P.H. Kooyman, P. Bergveld and J. Greve, Competitive immunological detection of progesterone by means of the ion-step induced response of an immunoFET, Sensors and Actuators, B1 (1990) 368-372.
-
(1990)
Sensors and Actuators, B
, vol.1
, pp. 368-372
-
-
Schasfoort, R.B.M.1
Keldermans, C.E.J.M.2
Kooyman, R.P.H.3
Bergveld, P.4
Greve, J.5
-
15
-
-
0031277831
-
Detection of protein concentrations with chronopotentiometry
-
submitted for publication
-
P. Bergveld, J.C.T. Eijkel and W. Olthuis, Detection of protein concentrations with chronopotentiometry, Biosensors Bioelectron., submitted for publication.
-
Biosensors Bioelectron.
-
-
Bergveld, P.1
Eijkel, J.C.T.2
Olthuis, W.3
-
16
-
-
0026138228
-
pH measurements with an ion-sensitive field-effect transistor in the mouth of patients with xerostomia
-
L.L. Visch, P. Bergveld, W. Lamprecht and E.J. 's-Gravenmade, pH measurements with an ion-sensitive field-effect transistor in the mouth of patients with xerostomia, IEEE Trans. Biomed. Eng., 38 (1991) 353-357.
-
(1991)
IEEE Trans. Biomed. Eng.
, vol.38
, pp. 353-357
-
-
Visch, L.L.1
Bergveld, P.2
Lamprecht, W.3
'S-Gravenmade, E.J.4
|