메뉴 건너뛰기




Volumn 79, Issue 7, 1996, Pages 69-75

Enzyme biosensor based on surface acoustic wave device

Author keywords

Acoustoelectric interaction; Enzyme sensor; High sensitivity; Shear horizontal surface wave; Urease

Indexed keywords

ACOUSTIC SURFACE WAVE DEVICES; ACOUSTIC WAVE TRANSMISSION; CHEMICAL SENSORS; CRYSTALS; ELECTRIC PROPERTIES; LIQUIDS; PH; PIEZOELECTRIC MATERIALS; PIEZOELECTRICITY;

EID: 0030198143     PISSN: 8756663X     EISSN: None     Source Type: Journal    
DOI: 10.1002/ecjb.4420790708     Document Type: Article
Times cited : (11)

References (12)
  • 1
    • 5244243790 scopus 로고
    • Biosensing by piezoelectric devices
    • Jan.
    • Muramatsu. Biosensing by piezoelectric devices. Heredity, 43, No. 1, pp. 25-29 (Jan. 1989).
    • (1989) Heredity , vol.43 , Issue.1 , pp. 25-29
    • Muramatsu1
  • 2
    • 0027710847 scopus 로고
    • Application of unidirectional transducers in acoustic plate mode biosensors
    • Baltimore, MD, U.S.A., Nov.
    • J. C. Andle, J. T. Weaver, J. F. Vetelino, D. J. McAllister, and F. Josse. Application of unidirectional transducers in acoustic plate mode biosensors. Proc. IEEE U.S. Symp., Baltimore, MD, U.S.A., pp. 331-335 (Nov. 1993).
    • (1993) Proc. IEEE U.S. Symp. , pp. 331-335
    • Andle, J.C.1    Weaver, J.T.2    Vetelino, J.F.3    McAllister, D.J.4    Josse, F.5
  • 3
    • 5244325585 scopus 로고
    • Maruzen Publ.
    • Sasabe (Ed.). Bio-Devices, pp. 67-101. Maruzen Publ. (1991).
    • (1991) Bio-Devices , pp. 67-101
    • Sasabe1
  • 4
    • 0023560674 scopus 로고
    • New sensor in liquid using leaky SAW
    • Denver, CO, U.S.A.
    • T. Moriizumi, Y. Unno, and S. Shiokawa. New sensor in liquid using leaky SAW. Proc. IEEE U.S. Symp., Denver, CO, U.S.A., pp. 579-582 (1987).
    • (1987) Proc. IEEE U.S. Symp. , pp. 579-582
    • Moriizumi, T.1    Unno, Y.2    Shiokawa, S.3
  • 5
    • 5244232462 scopus 로고
    • Liquid sensor using SH-SAW device
    • May
    • Kondo and Shiokawa. Liquid sensor using SH-SAW device. Trans. I.E.I.C.E. (C-II), J75-C-II, No. 5, pp. 224-234 (May 1992).
    • (1992) Trans. I.E.I.C.E. (C-II) , vol.J75-C-II , Issue.5 , pp. 224-234
    • Kondo1    Shiokawa2
  • 6
    • 5244232199 scopus 로고
    • SH-SAW sensor based on acousto-electric interaction
    • Aug.
    • Kondo and Shiokawa. SH-SAW sensor based on acousto-electric interaction. Trans. I.E.I.C.E. (C-II), J77-C-II), No. 8, pp. 338-347 (Aug. 1994).
    • (1994) Trans. I.E.I.C.E. (C-II) , vol.J77-C-II , Issue.8 , pp. 338-347
    • Kondo1    Shiokawa2
  • 7
    • 0027591564 scopus 로고
    • A shear horizontal SAW device as a pH monitor
    • May
    • I. Kondoh, S. Shiokawa, and Z. Gerogiev. A shear horizontal SAW device as a pH monitor. Sensors and Actuators B, B13, No. 1-3, pp. 429-431 (May 1993).
    • (1993) Sensors and Actuators B , vol.B13 , Issue.1-3 , pp. 429-431
    • Kondoh, I.1    Shiokawa, S.2    Gerogiev, Z.3
  • 10
    • 0022664625 scopus 로고
    • A lift-off method for patterning enzyme-immobilized membranes in multibiosensors
    • S. Nakamoto, N. Ito, T. Kuriyama, and J. Kimura. A lift-off method for patterning enzyme-immobilized membranes in multibiosensors. Sensors and Actuators, 13, pp. 165-172 (1988).
    • (1988) Sensors and Actuators , vol.13 , pp. 165-172
    • Nakamoto, S.1    Ito, N.2    Kuriyama, T.3    Kimura, J.4
  • 12
    • 5244228298 scopus 로고
    • Measurement of Temperature Dependence of Viscous Fluid by SAW Oscillator Sensor
    • Fukai, Kondo, Shiokawa, and Suzuki. Measurement of Temperature Dependence of Viscous Fluid by SAW Oscillator Sensor. Jour. Acoustic Society, Meeting Abstract, pp. 1045-1046 (1994).
    • (1994) Jour. Acoustic Society, Meeting Abstract , pp. 1045-1046
    • Fukai1    Kondo2    Shiokawa3    Suzuki4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.