메뉴 건너뛰기




Volumn 38, Issue 7, 1996, Pages 296-299

Comparison of Jaffé rate assay and enzymatic method for the measurement of creatinine clearance

Author keywords

Creatinine; Creatinine clearance; Enzymatic method; Equation; Jaff rate assay

Indexed keywords

AMIDASE; CREATININASE; CREATININE;

EID: 0030191533     PISSN: 03852385     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (48)

References (10)
  • 1
    • 0018826078 scopus 로고
    • Creatinine: A review
    • Narayan S, Appleton HD: Creatinine: a review. Clin Chem 26: 1119-1126, 1980
    • (1980) Clin Chem , vol.26 , pp. 1119-1126
    • Narayan, S.1    Appleton, H.D.2
  • 2
    • 0025893319 scopus 로고
    • Interferences in current methods for measurements of creatinine
    • Weber JA, van Zanten AP: Interferences in current methods for measurements of creatinine. Clin Chem. 37: 695-700, 1991
    • (1991) Clin Chem , vol.37 , pp. 695-700
    • Weber, J.A.1    Van Zanten, A.P.2
  • 3
    • 0023141433 scopus 로고
    • Interference by the new antibiotic cefpirome and other cephalosporins in clinical laboratory tests, with special regard to the ''Jaffé" reaction
    • Grotsch H, Hajdu P: Interference by the new antibiotic cefpirome and other cephalosporins in clinical laboratory tests, with special regard to the ''Jaffé" reaction. J Clin Chem Clin Biochem. 25: 49-52, 1987
    • (1987) J Clin Chem Clin Biochem , vol.25 , pp. 49-52
    • Grotsch, H.1    Hajdu, P.2
  • 4
    • 0042211243 scopus 로고
    • Creatinine
    • ed by Kaplan LA. Pesce AJ, The C.V. Mosby Company. Missouri (2nd ed)
    • Murray R: Creatinine. In: Clinical Chemistry: Theory, analysis, and correlation; ed by Kaplan LA. Pesce AJ, The C.V. Mosby Company. Missouri (2nd ed), pp 1015-1021, 1989
    • (1989) Clinical Chemistry: Theory, Analysis, and Correlation , pp. 1015-1021
    • Murray, R.1
  • 5
    • 0025981017 scopus 로고
    • High-performance liquid Chromatographic determination of creatinine
    • Ekelund S, Paby P: High-performance liquid Chromatographic determination of creatinine. Scand J Clin Lab Invest. 51: 67-71, 1991
    • (1991) Scand J Clin Lab Invest. , vol.51 , pp. 67-71
    • Ekelund, S.1    Paby, P.2
  • 6
    • 0027674945 scopus 로고
    • Endogenous creatinine clearance measurement of glomerular nitration rate in dogs
    • Finco DR, Tabaru H, Brown SA, Barsanti JA: Endogenous creatinine clearance measurement of glomerular nitration rate in dogs. Am J Vet Res. 54: 1575-1578, 1993
    • (1993) Am J Vet Res , vol.54 , pp. 1575-1578
    • Finco, D.R.1    Tabaru, H.2    Brown, S.A.3    Barsanti, J.A.4
  • 8
    • 0025788439 scopus 로고
    • A comparison of two common clinical methods with high-pressure liquid chromatography for the measurement of creatinine concentrations in neonates
    • Bennett LN, Jandreski MA, Myers TF, Kahn SE, Hurley RM: A comparison of two common clinical methods with high-pressure liquid chromatography for the measurement of creatinine concentrations in neonates.. Pediatr Nephrol 5: 379-382, 1991
    • (1991) Pediatr Nephrol , vol.5 , pp. 379-382
    • Bennett, L.N.1    Jandreski, M.A.2    Myers, T.F.3    Kahn, S.E.4    Hurley, R.M.5
  • 9
    • 0016916438 scopus 로고
    • Prediction of creatinine clearance from serum creatinine
    • Cockeroft RW, Gault MH: Prediction of creatinine clearance from serum creatinine. Nephron 16: 31-41, 1976
    • (1976) Nephron , vol.16 , pp. 31-41
    • Cockeroft, R.W.1    Gault, M.H.2
  • 10
    • 0021752819 scopus 로고
    • Prediction of creatinine clearance from serum creatininc concentration
    • Konishi K, Saruta T, Abe S, Wada T, Ozawa Y, Kato E: Prediction of creatinine clearance from serum creatininc concentration: Jap J Nephrol 26: 1195-1202, 1984
    • (1984) Jap J Nephrol , vol.26 , pp. 1195-1202
    • Konishi, K.1    Saruta, T.2    Abe, S.3    Wada, T.4    Ozawa, Y.5    Kato, E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.