메뉴 건너뛰기




Volumn 24, Issue 3, 1996, Pages 191-197

Rapid communication Cy7PE and Cy7APC: Bright new probes for immunofluorescence

Author keywords

Allophycocyanin; Cyanine; Measurements; Multiparameter; Phycoerythrin; Resonance energy transfer; Tandem dyes

Indexed keywords

ALLOPHYCOCYANIN; DYE; FLUORESCENT DYE; PHYCOERYTHRIN; CARBOCYANINE; COLORING AGENT; LEUKOCYTE ANTIGEN; PHYCOCYANIN;

EID: 0030187985     PISSN: 01964763     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-0320(19960701)24:3<191::AID-CYTO1>3.0.CO;2-L     Document Type: Article
Times cited : (80)

References (10)
  • 1
    • 0020827097 scopus 로고
    • Fluorescent tandem phycobiliprotein conjugates. Emission wavelength shifting by energy transfer
    • Glazer AN, Stryer L: Fluorescent tandem phycobiliprotein conjugates. Emission wavelength shifting by energy transfer. Biophys J 43:383-386, 1983.
    • (1983) Biophys J , vol.43 , pp. 383-386
    • Glazer, A.N.1    Stryer, L.2
  • 2
    • 0001103142 scopus 로고
    • Purification and coupling of fluorescent proteins for use in flow cytometry
    • Weir DM, Herzenberg LA, Blackwell C, Herzenberg LA (eds). Blackwell Scientific Publications, Boston
    • Hardy RR: Purification and coupling of fluorescent proteins for use in flow cytometry. In: Handbook of Experimental Immunology, 4th ed, Weir DM, Herzenberg LA, Blackwell C, Herzenberg LA (eds). Blackwell Scientific Publications, Boston, 1986, pp 31.1-31.12.
    • (1986) Handbook of Experimental Immunology, 4th Ed , pp. 311-3112
    • Hardy, R.R.1
  • 3
    • 0026048403 scopus 로고
    • Single laser three color immunofluorescence staining procedures based on energy transfer between phycoerythrin and cyanine 5
    • Lansdorp PM, Smith C, Safford M, Terstappen LW, Thomas TE: Single laser three color immunofluorescence staining procedures based on energy transfer between phycoerythrin and cyanine 5. Cytometry 12:723-730, 1991.
    • (1991) Cytometry , vol.12 , pp. 723-730
    • Lansdorp, P.M.1    Smith, C.2    Safford, M.3    Terstappen, L.W.4    Thomas, T.E.5
  • 4
    • 0009534245 scopus 로고
    • Data analysis in flow cytometry
    • Weir DM, Herzenberg LA, Blackwell CM, Herzenberg LA (eds). Blackwell Scientific Publications, Boston
    • Moore WA, Kautz RA: Data analysis in flow cytometry. In: Handbook of Experimental Immunology, 4th ed, Weir DM, Herzenberg LA, Blackwell CM, Herzenberg LA (eds). Blackwell Scientific Publications, Boston, 1986, pp 30.1-30.11.
    • (1986) Handbook of Experimental Immunology, 4th Ed , pp. 301-3011
    • Moore, W.A.1    Kautz, R.A.2
  • 7
    • 0027262235 scopus 로고
    • Control of lymphocyte recirculation in man. I. Differential regulation of the peripheral lymph node homing receptor L-selection on T cells during the virgin to memory cell transition
    • Picker LJ, Treer JR, Ferguson DB, Collins PA, Buck D, Terstappen LW: Control of lymphocyte recirculation in man. I. Differential regulation of the peripheral lymph node homing receptor L-selection on T cells during the virgin to memory cell transition. J Immunol 150: 1105-1121, 1993.
    • (1993) J Immunol , vol.150 , pp. 1105-1121
    • Picker, L.J.1    Treer, J.R.2    Ferguson, D.B.3    Collins, P.A.4    Buck, D.5    Terstappen, L.W.6
  • 8
  • 10
    • 0027319558 scopus 로고
    • PE-CY5. A new fluorescent antibody label for three-color flow cytometry with a single laser
    • Waggoner AS, Ernst LA, Chen CH, Rechtenwald DJ: PE-CY5. A new fluorescent antibody label for three-color flow cytometry with a single laser. Ann NY Acad Sci 677:185-193, 1993.
    • (1993) Ann NY Acad Sci , vol.677 , pp. 185-193
    • Waggoner, A.S.1    Ernst, L.A.2    Chen, C.H.3    Rechtenwald, D.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.