Volumn 29, Issue 6, 1996, Pages 829-832

Thickness measurement of soft tissue biomaterials: A comparison of five methods

Author keywords

Hall effect; Instrumentation; Mechanical testing; Pericardium; Soft tissue; Thickness

Indexed keywords

ELECTRIC RESISTANCE; HALL EFFECT; LIGHT POLARIZATION; MECHANICAL TESTING; STRAIN GAGES; THICKNESS MEASUREMENT; TISSUE CULTURE;

EID: 0030175835     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/0021-9290(95)00121-2     Document Type: Article
Times cited : (37)

References (12)
  • 1
    • 0018565978 scopus 로고
    • Pressure dependence of the area micrometer method in evaluation of cruciate ligament cross-section
    • Allard, P., Thiry, P. S., Bourgault, A. and Drouin, G. (1979) Pressure dependence of the area micrometer method in evaluation of cruciate ligament cross-section. J. Biomed. Engng 1, 265-267.
    • (1979) J. Biomed. Engng , vol.1 , pp. 265-267
    • Allard, P.1    Thiry, P.S.2    Bourgault, A.3    Drouin, G.4
  • 2
    • 0025031776 scopus 로고
    • Ultrasound velocity in human fingernail and effects of hydration: Validation of in vivo nail thickness measurement techniques
    • Finlay, A. Y., Western, B. and Edwards, C. (1990) Ultrasound velocity in human fingernail and effects of hydration: validation of in vivo nail thickness measurement techniques. Br. J. Dermatol. 123, 365-373.
    • (1990) Br. J. Dermatol. , vol.123 , pp. 365-373
    • Finlay, A.Y.1    Western, B.2    Edwards, C.3
  • 3
    • 0025894894 scopus 로고
    • What are the residual stresses doing in our blood vessels?
    • Fung, Y. C. (1991) What are the residual stresses doing in our blood vessels? Ann. Biomed. Engng 19, 237-249.
    • (1991) Ann. Biomed. Engng , vol.19 , pp. 237-249
    • Fung, Y.C.1
  • 5
    • 0022386915 scopus 로고
    • Mechanical properties of human pericardium: Differences in viscoelastic response compared with canine pericardium
    • Lee, J. M. and Boughner, D. R. (1985) Mechanical properties of human pericardium: differences in viscoelastic response compared with canine pericardium. Circ. Res. 55, 475-481.
    • (1985) Circ. Res. , vol.55 , pp. 475-481
    • Lee, J.M.1    Boughner, D.R.2
  • 6
    • 0023279703 scopus 로고
    • Biaxial mechanical properties of human pericardium and canine comparisons
    • Lee, M. C., Fung, Y. C., Shabetai, R. et al. (1987) Biaxial mechanical properties of human pericardium and canine comparisons. Am. J. Physiol. 253, H75-H82.
    • (1987) Am. J. Physiol. , vol.253
    • Lee, M.C.1    Fung, Y.C.2    Shabetai, R.3
  • 7
    • 0024673537 scopus 로고
    • The bovine pericardial xenograft: I. Effect of fixation in aldehydes without constraint on the tensile viscoelastic properties of bovine pericardium
    • Lee, J. M., Haberer, S. A. and Boughner, D. R. (1989) The bovine pericardial xenograft: I. Effect of fixation in aldehydes without constraint on the tensile viscoelastic properties of bovine pericardium. J. Biomed. Mater. Res. 23, 457-475.
    • (1989) J. Biomed. Mater. Res. , vol.23 , pp. 457-475
    • Lee, J.M.1    Haberer, S.A.2    Boughner, D.R.3
  • 8
    • 0024017397 scopus 로고
    • A new method for determining cross-sectional shape and area of soft tissues
    • Lee, T. Q. and Woo, S. L.-Y. (1988) A new method for determining cross-sectional shape and area of soft tissues. J. Biomech. Engng 110, 110-114.
    • (1988) J. Biomech. Engng , vol.110 , pp. 110-114
    • Lee, T.Q.1    Woo, S.L.-Y.2
  • 9
    • 0024017408 scopus 로고
    • A new method of measuring the cross-sectional area of connective tissue structures
    • Shrive, N. G., Lam, T. C., Damson, E. and Frank, C. B. (1988) A new method of measuring the cross-sectional area of connective tissue structures. J. Biomech. Engng. 110, 104-109.
    • (1988) J. Biomech. Engng. , vol.110 , pp. 104-109
    • Shrive, N.G.1    Lam, T.C.2    Damson, E.3    Frank, C.B.4
  • 10
    • 0020028630 scopus 로고
    • Skin thickness measurement by pulsed ultrasound: Its reproducibility, validation, and variability
    • Tan, C. Y., Statham, B., Marks, R. and Payne, P. A. (1982) Skin thickness measurement by pulsed ultrasound: its reproducibility, validation, and variability. Br. J. Dermatol. 106, 657-667.
    • (1982) Br. J. Dermatol. , vol.106 , pp. 657-667
    • Tan, C.Y.1    Statham, B.2    Marks, R.3    Payne, P.A.4
  • 11
    • 0022902834 scopus 로고
    • The standardization of gauge length: Its influence on the relative extensibility of natural and chemically modified pericardium
    • Trowbridge, E. A. and Crofts, C. E. (1986) The standardization of gauge length: its influence on the relative extensibility of natural and chemically modified pericardium. J. Biomechanics 19, 1023-1033.
    • (1986) J. Biomechanics , vol.19 , pp. 1023-1033
    • Trowbridge, E.A.1    Crofts, C.E.2
  • 12
    • 0025689366 scopus 로고
    • The use of a laser micrometer system to determine the cross-sectional shape and area of ligaments: A comparative study with two existing methods
    • Woo, S. L., Danto, M. I., Ohland, K. J., Lee, T. Q. and Newton, P. O. (1990) The use of a laser micrometer system to determine the cross-sectional shape and area of ligaments: a comparative study with two existing methods. J. Biomech. Engng 112, 426-431.
    • (1990) J. Biomech. Engng , vol.112 , pp. 426-431
    • Woo, S.L.1    Danto, M.I.2    Ohland, K.J.3    Lee, T.Q.4    Newton, P.O.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.