메뉴 건너뛰기




Volumn 4, Issue 2, 1996, Pages 114-119

A PC-based ultrasonic data acquisition system for computer-aided prosthetic socket design

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER AIDED DESIGN; DATA ACQUISITION; IMAGE RECONSTRUCTION; MATHEMATICAL MODELS; MEASUREMENT ERRORS; PERSONAL COMPUTERS; THREE DIMENSIONAL; ULTRASONICS; VISUALIZATION;

EID: 0030175798     PISSN: 10636528     EISSN: None     Source Type: Journal    
DOI: 10.1109/86.506408     Document Type: Article
Times cited : (31)

References (24)
  • 1
    • 0021309523 scopus 로고
    • R. T. Goldberg New trends in the rehabilitation of lower extremity amputees Rehab. Lit. 45 1— 2 11 1984
    • (1984) , vol.45 , Issue.1— , pp. 2-11
    • Goldberg, R.T.1
  • 4
    • 0012702290 scopus 로고
    • J. Foort The patellar-tendon-bearing prosthesis for below-knee amputees, a review of technique and criteria Artific. Limbs 9 1 4 13 1965
    • (1965) , vol.9 , Issue.1 , pp. 4-13
    • Foort, J.1
  • 7
    • 0020445227 scopus 로고
    • D. E. Robinson P. C. Knight Interpolation scan conversion in pulse-echo ultrasound Ultrason. Imaging 4 297 310 1982
    • (1982) , vol.4 , pp. 297-310
    • Robinson, D.E.1    Knight, P.C.2
  • 9
    • 85176667070 scopus 로고
    • Washington, Seattle
    • J. W. Steege D. S. Childress Finite element prediction of pressure at the below-knee socket interface Rep. ISPO Workshop CAD/CAM Prosthet. Orthot. 71 82 8𔃀 June 1988 Washington, Seattle
    • (1988) , pp. 71-82
    • Steege, J.W.1    Childress, D.S.2
  • 10
    • 0027752359 scopus 로고
    • J. E. Sanders C. H. Daly Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: Comparison of finite element results with experimental measurements J. Rehabil. Res. Dev. 30 2 191 204 1993
    • (1993) , vol.30 , Issue.2 , pp. 191-204
    • Sanders, J.E.1    Daly, C.H.2
  • 11
    • 0029378353 scopus 로고
    • K. E. Smith M. W. Vannier P. K. Commean Spiral CT volumetry of below-knee residua IEEE Trans. Rehab. Eng. 3 235 241 Sept. 1995 86 9209 413196
    • (1995) , vol.3 , pp. 235-241
    • Smith, K.E.1    Vannier, M.W.2    Commean, P.K.3
  • 12
    • 85176669475 scopus 로고
    • Academic UK, London
    • P. N. T. Wells Biomedical Ultrasonics 1977 Academic UK, London
    • (1977)
    • Wells, P.N.T.1
  • 14
    • 0026287557 scopus 로고
    • P. He K. Xue H. A. Bismar H. Fu P. Murka Application of ultrasonic imaging technique to prosthetic socket design Proc. Annu. Int. Conf. IEEE Eng. Medic. Bio. Soc. 13 1849 1850 1991 1015 7498 684786
    • (1991) , vol.13 , pp. 1849-1850
    • He, P.1    Xue, K.2    Bismar, H.A.3    Fu, H.4    Murka, P.5
  • 15
    • 0026406202 scopus 로고
    • K. Xue P. He H. Fu H. A. Bismar An ultrasonic B-scan image compounding technique for prosthetic socket design SPIE Proc. 1606 675 684 1991
    • (1991) , vol.1606 , pp. 675-684
    • Xue, K.1    He, P.2    Fu, H.3    Bismar, H.A.4
  • 16
    • 1842268070 scopus 로고
    • A. F. Fares J. J. Giesey S. Ghosh G. S. Chleboun J. N. Howell Using ultrasound 3D compound imaging to illustrate the effects of intermittent pneumatic compression treatment on swollen upper arm Ultrason. Imaging 15 173 1993
    • (1993) , vol.15 , pp. 173
    • Fares, A.F.1    Giesey, J.J.2    Ghosh, S.3    Chleboun, G.S.4    Howell, J.N.5
  • 17
    • 0018460724 scopus 로고
    • J. Ophir N. F. Maklad Digital scan converters in diagnostic ultrasound imaging Proc. IEEE. 67 654 664 1979
    • (1979) , vol.67 , pp. 654-664
    • Ophir, J.1    Maklad, N.F.2
  • 18
    • 0022396310 scopus 로고
    • S.-W. Lee S.-B. Park A new scan conversion algorithm for ultrasound compound scanning Ultrason. Imaging 7 3 215 224 1985
    • (1985) , vol.7 , Issue.3 , pp. 215-224
    • Lee, S.-W.1    Park, S.-B.2
  • 19
    • 0027934177 scopus 로고
    • W. D. Richard R. M. Arthur Real-time ultrasonic scan conversion via linear interpolation of oversampled vectors Ultrason. Imaging 16 2 109 123 1994
    • (1994) , vol.16 , Issue.2 , pp. 109-123
    • Richard, W.D.1    Arthur, R.M.2
  • 21
    • 0019867553 scopus 로고
    • D. E. Robinson P. C. Knight Computer reconstruction techniques in compound scan pulse-echo imaging Ultrason. Imaging 3 217 234 1981
    • (1981) , vol.3 , pp. 217-234
    • Robinson, D.E.1    Knight, P.C.2
  • 22
    • 85176671464 scopus 로고
    • Prentice-Hall NJ, Englewood Cliffs
    • H. R. Myler A. R. Weeks Computer Imaging Recipes in C 1993 Prentice-Hall NJ, Englewood Cliffs
    • (1993)
    • Myler, H.R.1    Weeks, A.R.2
  • 23
    • 85176672767 scopus 로고
    • P. He K. Xue A PC-based ultrasound scanning system for imaging a residual limb Proc. 16th Annu. Int. Conf. IEEE Eng. Med. Bio. Soc. 480 481 1994 3230 9197 411944
    • (1994) , pp. 480-481
    • He, P.1    Xue, K.2
  • 24
    • 85176689396 scopus 로고
    • New York
    • D. A. Christensen Ultrasonic Bioinstrumentation 1988 New York
    • (1988)
    • Christensen, D.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.