-
1
-
-
0026192044
-
Microbial differences in two clinically distinct types of failures in osseointegrated implants
-
Rosenberg ES, Torosian JP, Slots J. Microbial differences in two clinically distinct types of failures in osseointegrated implants. Clin Oral Impl Res 1991; 2: 135-144.
-
(1991)
Clin Oral Impl Res
, vol.2
, pp. 135-144
-
-
Rosenberg, E.S.1
Torosian, J.P.2
Slots, J.3
-
2
-
-
0029175464
-
Factors related to success and failure rates follow-up in a multicenter study of overdentures supported by Branemark implants
-
Hutton JE, Heath MR, Chai JY et al. Factors related to success and failure rates follow-up in a multicenter study of overdentures supported by Branemark implants. Int J Oral Maxillofac Implants 1995; 10: 33-42.
-
(1995)
Int J Oral Maxillofac Implants
, vol.10
, pp. 33-42
-
-
Hutton, J.E.1
Heath, M.R.2
Chai, J.Y.3
-
3
-
-
85016033318
-
Mechanical loading of Branemark implants affects interfacial bone modeling and remodeling
-
Hoshaw SJ, Brunski JB, Cochran GVB. Mechanical loading of Branemark implants affects interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants 1994; 9: 345-360.
-
(1994)
Int J Oral Maxillofac Implants
, vol.9
, pp. 345-360
-
-
Hoshaw, S.J.1
Brunski, J.B.2
Cochran, G.V.B.3
-
4
-
-
0027035024
-
Plaque-induced marginal tissue reactions of osseointegrated oral implants: A review of the literature
-
Schou S, Holmstrup P, Hjorting-Hansen E, Lang NP. Plaque-induced marginal tissue reactions of osseointegrated oral implants: a review of the literature. Clin Oral Impl Res 1992; 3: 149-161.
-
(1992)
Clin Oral Impl Res
, vol.3
, pp. 149-161
-
-
Schou, S.1
Holmstrup, P.2
Hjorting-Hansen, E.3
Lang, N.P.4
-
5
-
-
85030210211
-
Forces on dental implants and interfacial stress transfer
-
Laney WR, Tolman DE, eds. Mayo Medical Center, Rochester, MN, 23-27 September, 1990. Chicago, IL: Quintessence Publishing
-
Brunski JB. Forces on dental implants and interfacial stress transfer. In: Laney WR, Tolman DE, eds. Tissue Integration in Oral, Orthopedic and maxillofacial Reconstruction, Proceedings of the Second International Congress on Tissue Integration in Oral, Orthopedic, and Maxillofacial Reconstruction, Mayo Medical Center, Rochester, MN, 23-27 September, 1990. Chicago, IL: Quintessence Publishing, 1992.
-
(1992)
Tissue Integration in Oral, Orthopedic and Maxillofacial Reconstruction, Proceedings of the Second International Congress on Tissue Integration in Oral, Orthopedic, and Maxillofacial Reconstruction
-
-
Brunski, J.B.1
-
8
-
-
0002611019
-
Osseointegration: A requiem for the periodontal ligament?
-
Zarb G. Osseointegration: a requiem for the periodontal ligament? Int J Penodont Rest Dent 1991; 11: 88-91.
-
(1991)
Int J Penodont Rest Dent
, vol.11
, pp. 88-91
-
-
Zarb, G.1
-
9
-
-
0024837433
-
Comparison of peri-implant stresses transmitted by four commercially available osseointegrated implants
-
French AA, Bowles CP, Parham PL, Eick JD, Killoy WJ, Cobb CM. Comparison of peri-implant stresses transmitted by four commercially available osseointegrated implants. Int J Periodont Rest Dent 1989; 9: 221-230.
-
(1989)
Int J Periodont Rest Dent
, vol.9
, pp. 221-230
-
-
French, A.A.1
Bowles, C.P.2
Parham, P.L.3
Eick, J.D.4
Killoy, W.J.5
Cobb, C.M.6
-
10
-
-
0026166926
-
Dental implants retrieved from humans: A diagnostic light microscopic review of the findings in seven cases of failure
-
Steflik DE, McKinney RV, Sisk AL, Parr GR, Marshall BL. Dental implants retrieved from humans: a diagnostic light microscopic review of the findings in seven cases of failure. Int J Oral Maxillofac Implants 1991; 6: 147-153.
-
(1991)
Int J Oral Maxillofac Implants
, vol.6
, pp. 147-153
-
-
Steflik, D.E.1
McKinney, R.V.2
Sisk, A.L.3
Parr, G.R.4
Marshall, B.L.5
-
12
-
-
0026192131
-
Structure of the bone-titanium interface in retrieved clinical oral implants
-
Sennerby L, Ericsson LE, Thomsen P, Lekholm U, Astrand P. Structure of the bone-titanium interface in retrieved clinical oral implants. Clin Oral Impl Res 1991; 2: 103-111.
-
(1991)
Clin Oral Impl Res
, vol.2
, pp. 103-111
-
-
Sennerby, L.1
Ericsson, L.E.2
Thomsen, P.3
Lekholm, U.4
Astrand, P.5
-
13
-
-
0028249631
-
Light microscopic and scanning electron microscopic analyses of dental implants retrieved from humans
-
Steflik DE, Parr GR, Singh BB et al. Light microscopic and scanning electron microscopic analyses of dental implants retrieved from humans. J Oral Implantol 1994; 20: 8-14.
-
(1994)
J Oral Implantol
, vol.20
, pp. 8-14
-
-
Steflik, D.E.1
Parr, G.R.2
Singh, B.B.3
-
14
-
-
0028510728
-
Histologic evidence of osseointegration 4 years after implantation. A case report
-
Grätz KW, Zimmermann AP, Sailer HF. Histologic evidence of osseointegration 4 years after implantation. A case report. Clin Oral Impl Res 1994; 5: 173-176.
-
(1994)
Clin Oral Impl Res
, vol.5
, pp. 173-176
-
-
Grätz, K.W.1
Zimmermann, A.P.2
Sailer, H.F.3
-
16
-
-
0000515698
-
Influence of biomechanical factors at the bone-biomaterials interface
-
Davies JE, ed. Toronto: Toronto University Press
-
Brunski JB. Influence of biomechanical factors at the bone-biomaterials interface. In: Davies JE, ed. Bone Biomaterial Interface. Toronto: Toronto University Press, 1991: 391-405.
-
(1991)
Bone Biomaterial Interface
, pp. 391-405
-
-
Brunski, J.B.1
|