메뉴 건너뛰기




Volumn 33, Issue 2, 1996, Pages 115-119

Is there any difference between vacuum mixing systems in reducing bone cement porosity?

Author keywords

[No Author keywords available]

Indexed keywords

ATMOSPHERIC PRESSURE; FAILURE (MECHANICAL); HIP PROSTHESES; MIXING; POROSITY; VACUUM APPLICATIONS; VISCOSITY;

EID: 0030175699     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4636(199622)33:2<115::AID-JBM8>3.0.CO;2-U     Document Type: Article
Times cited : (55)

References (15)
  • 1
    • 0027381820 scopus 로고
    • Prognosis of total hip replacement in Sweden. Follow-up of 92,675 operations performed 1978-1990
    • Malchau, H.; Herberts, P.; Ahnfelt, L. Prognosis of total hip replacement in Sweden. Follow-up of 92,675 operations performed 1978-1990. Acta Orthop. Scand. 64:497-506; 1993.
    • (1993) Acta Orthop. Scand. , vol.64 , pp. 497-506
    • Malchau, H.1    Herberts, P.2    Ahnfelt, L.3
  • 2
    • 0019981269 scopus 로고
    • Ten-year follow-up study of total hip replacement. with particular reference to roentgenographic loosening of the components
    • Stauffer, R. N. Ten-year follow-up study of total hip replacement. With particular reference to roentgenographic loosening of the components. J. Bone Joint Surg. 64A:983-990; 1982.
    • (1982) J. Bone Joint Surg. , vol.64 A , pp. 983-990
    • Stauffer, R.N.1
  • 5
    • 0025388865 scopus 로고
    • A fractographic analysis of in vivo poly(methylmethacrylate) bone cement failure mechanisms
    • Topoleski, L. D. T.; Ducheyne, P.; Cuckler, J. M. A fractographic analysis of in vivo poly(methylmethacrylate) bone cement failure mechanisms. J. Biomed. Mater. Res. 24:135-154; 1990.
    • (1990) J. Biomed. Mater. Res. , vol.24 , pp. 135-154
    • Topoleski, L.D.T.1    Ducheyne, P.2    Cuckler, J.M.3
  • 6
    • 0026864135 scopus 로고
    • A fractographic investigation of PMMA bone cement focusing on the relationship between porosity reduction and increased fatigue life
    • James, S. P.; Jasty, M.; Davies, J.; Piehler, A. A fractographic investigation of PMMA bone cement focusing on the relationship between porosity reduction and increased fatigue life. J. Biomed. Mater. Res. 26:651-662; 1992.
    • (1992) J. Biomed. Mater. Res. , vol.26 , pp. 651-662
    • James, S.P.1    Jasty, M.2    Davies, J.3    Piehler, A.4
  • 7
    • 0023875026 scopus 로고
    • The effect of centrifugation on the fatigue life of bone cement in the presence of surface irregularities
    • Davies, J. P.; O'Connor, D. O.; Burke, D. W.; Jasty, M.; Harris, W. H. The effect of centrifugation on the fatigue life of bone cement in the presence of surface irregularities. Clin. Orthop. 229:156-161; 1988.
    • (1988) Clin. Orthop. , vol.229 , pp. 156-161
    • Davies, J.P.1    O'Connor, D.O.2    Burke, D.W.3    Jasty, M.4    Harris, W.H.5
  • 8
    • 0021747492 scopus 로고
    • Strength of polymethylmethacrylate increased by vacuum mixing
    • Lidgren, L.; Drar, H.; Möller, J. Strength of polymethylmethacrylate increased by vacuum mixing. Acta Orthop. Scand. 55:536-541; 1984.
    • (1984) Acta Orthop. Scand. , vol.55 , pp. 536-541
    • Lidgren, L.1    Drar, H.2    Möller, J.3
  • 10
    • 0024347288 scopus 로고
    • Fatigue properties of bone cement
    • Linden, U. Fatigue properties of bone cement. Acta Orthop. Scand. 60:431-433; 1989.
    • (1989) Acta Orthop. Scand. , vol.60 , pp. 431-433
    • Linden, U.1
  • 11
  • 12
    • 0027310129 scopus 로고
    • Porosity of Palacos R bone cement reduced by mixing and collecting under vacuum
    • Wang, J. S.; Franzén, H.; Jonsson, E.; Lidgren, L. Porosity of Palacos R bone cement reduced by mixing and collecting under vacuum. Acta Orthop. Scand. 64:143-146; 1993.
    • (1993) Acta Orthop. Scand. , vol.64 , pp. 143-146
    • Wang, J.S.1    Franzén, H.2    Jonsson, E.3    Lidgren, L.4
  • 14
    • 0029256536 scopus 로고
    • The effects of centrifugation and titanium fiber reinforcement on fatigue failure mechanisms in polymethylmethacrylate bone cement
    • Topoleski, L. D. T.; Ducheyne, P.; Cuckler, J. M. The effects of centrifugation and titanium fiber reinforcement on fatigue failure mechanisms in polymethylmethacrylate bone cement. J. Biomed. Mater. Res. 29:299-307; 1995.
    • (1995) J. Biomed. Mater. Res. , vol.29 , pp. 299-307
    • Topoleski, L.D.T.1    Ducheyne, P.2    Cuckler, J.M.3
  • 15
    • 0023511433 scopus 로고
    • High vacuum as a method of reducing porosity of polymethylmethacrylate
    • Alkire, M. J.; Dabezies, E. J.; Hastings, P. R. High vacuum as a method of reducing porosity of polymethylmethacrylate. Orthopedics 10:1533-1539; 1987.
    • (1987) Orthopedics , vol.10 , pp. 1533-1539
    • Alkire, M.J.1    Dabezies, E.J.2    Hastings, P.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.