메뉴 건너뛰기




Volumn 16, Issue 3, 1996, Pages 196-201

Temporal changes in VOC discharge to surface water from a fractured rock aquifer during well installation and operation, Greenville, South Carolina

Author keywords

[No Author keywords available]

Indexed keywords

AQUIFERS; BOREHOLES; CONTAMINATION; HYDRAULICS; IMPURITIES; MONITORING; ROCKS; SURFACE WATERS; VOLATILE ORGANIC COMPOUNDS; WASTEWATER TREATMENT; WATER TREATMENT PLANTS; WELL DRILLING;

EID: 0030166848     PISSN: 10693629     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1745-6592.1996.tb00150.x     Document Type: Article
Times cited : (8)

References (9)
  • 1
    • 0021473394 scopus 로고
    • Use of a permeation sampler for determination of volatile priority pollutants
    • Blanchard, R.D., and J.K. Hardy. 1984. Use of a permeation sampler for determination of volatile priority pollutants. Anal. Chem. 56, 1621-1624.
    • (1984) Anal. Chem. , vol.56 , pp. 1621-1624
    • Blanchard, R.D.1    Hardy, J.K.2
  • 2
    • 0022146317 scopus 로고
    • Use of a permeation sampler in the collection of 23 volatile organic priority pollutants
    • Blanchard, R.D., and J.K. Hardy. 1985. Use of a permeation sampler in the collection of 23 volatile organic priority pollutants. Anal. Chem. 2351-2357.
    • (1985) Anal. Chem. , pp. 2351-2357
    • Blanchard, R.D.1    Hardy, J.K.2
  • 3
    • 0022736198 scopus 로고
    • Continuous monitoring device for the collection of 23 volatile organic priority pollutants
    • Blanchard, R.D., and J.K. Hardy. 1986. Continuous monitoring device for the collection of 23 volatile organic priority pollutants. Anal. Chem. 58, 1529-1532.
    • (1986) Anal. Chem. , vol.58 , pp. 1529-1532
    • Blanchard, R.D.1    Hardy, J.K.2
  • 4
    • 85033809896 scopus 로고
    • Letter to GE Modeling Team, 28 February
    • Hartford, Mark. 1994. Letter to GE Modeling Team, 28 February.
    • (1994)
    • Hartford, M.1
  • 5
    • 3643079070 scopus 로고
    • General Electric Co., Gas Turbine Manufacturing Facility. Greenville, South Carolina: Rust Environment and Infrastructure
    • Rust Environment and Infrastructure. 1994. First quarter 1994 wastewater treatment plant area ground-water quality assessment report, General Electric Co., Gas Turbine Manufacturing Facility. Greenville, South Carolina: Rust Environment and Infrastructure.
    • (1994) First Quarter 1994 Wastewater Treatment Plant Area Ground-water Quality Assessment Report
  • 6
    • 3643066550 scopus 로고
    • General Electric Co., Gas Turbine Manufacturing Facility. Greenville, South Carolina: Rust Environment and Infrastructure
    • Rust Environment and Infrastructure. 1995. Fourth quarter and annual 1994 ground-water assessment report, General Electric Co., Gas Turbine Manufacturing Facility. Greenville, South Carolina: Rust Environment and Infrastructure.
    • (1995) Fourth Quarter and Annual 1994 Ground-water Assessment Report
  • 7
    • 0026155215 scopus 로고
    • Prospecting for zones of contaminated ground-water discharge to streams using bottom-sediment gas bubbles
    • Vroblesky, D. A., and M.M. Lorah. 1991. Prospecting for zones of contaminated ground-water discharge to streams using bottom-sediment gas bubbles. Ground Water 29, no. 3: 333-340.
    • (1991) Ground Water , vol.29 , Issue.3 , pp. 333-340
    • Vroblesky, D.A.1    Lorah, M.M.2
  • 8
    • 14444277822 scopus 로고
    • Mapping zones of contaminated ground-water discharge using creekbottom-sediment vapor samplers, Aberdeen Proving Ground, Maryland
    • Vroblesky, D.A., M.M. Lorah, and S.P. Trimble. 1991. Mapping zones of contaminated ground-water discharge using creekbottom-sediment vapor samplers, Aberdeen Proving Ground, Maryland. Ground Water 27, no. 1: 7-12.
    • (1991) Ground Water , vol.27 , Issue.1 , pp. 7-12
    • Vroblesky, D.A.1    Lorah, M.M.2    Trimble, S.P.3
  • 9
    • 0030104004 scopus 로고    scopus 로고
    • Locating VOC contamination in a fracturedrock aquifer at the ground-water/surface-water interface using passive vapor collectors
    • Vroblesky, D.A., L.C. Rhodes, J.F. Robertson, and J.A. Harrigan. 1996. Locating VOC contamination in a fracturedrock aquifer at the ground-water/surface-water interface using passive vapor collectors. Ground Water 34, no. 2: 223-230.
    • (1996) Ground Water , vol.34 , Issue.2 , pp. 223-230
    • Vroblesky, D.A.1    Rhodes, L.C.2    Robertson, J.F.3    Harrigan, J.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.