메뉴 건너뛰기




Volumn 15, Issue 3, 1996, Pages 260-267

CCD Mosaic technique for large-field digital mammography

Author keywords

[No Author keywords available]

Indexed keywords

CHARGE COUPLED DEVICES; DIGITAL SIGNAL PROCESSING; IMAGE ANALYSIS; TISSUE; X RAY RADIOGRAPHY;

EID: 0030165684     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/42.500135     Document Type: Article
Times cited : (29)

References (30)
  • 1
    • 0025230247 scopus 로고    scopus 로고
    • New Mammographie screen/film combinations: Imaging characteristics and radiation dose
    • vol. 154, pp. 713-719, 1990.
    • C. Kimme-Smith, L. W. Basset, R. H. Gold, and J. Uornbein, "New Mammographie screen/film combinations: Imaging characteristics and radiation dose," Am. J. Roenlgemil., vol. 154, pp. 713-719, 1990.
    • Am. J. Roenlgemil.
    • Kimme-Smith, C.1    Basset, L.W.2    Gold, R.H.3    Uornbein, J.4
  • 2
    • 0024277133 scopus 로고    scopus 로고
    • Imaging plate illuminates many fields
    • vol. 336, pp. 89, 1988.
    • Y. Amemiya and J. Miyahara, "Imaging plate illuminates many fields," Nature, vol. 336, pp. 89, 1988.
    • Nature
    • Amemiya, Y.1    Miyahara, J.2
  • 3
    • 0023700758 scopus 로고    scopus 로고
    • A comparison of digitized storage phosphors and conventional mammography in the detection of malignant microcalcifications
    • vol. 23, no. 725, 1988.
    • J. W. Oestmann, D. Kopans. and D. A. Hall. "A comparison of digitized storage phosphors and conventional mammography in the detection of malignant microcalcifications," Invest. Radiai, vol. 23, no. 725, 1988.
    • Invest. Radiai
    • Oestmann, J.W.1    Kopans, D.2    Hall, D.A.3
  • 4
    • 33747900104 scopus 로고    scopus 로고
    • Computerized digital radiography in the study of breast diseases
    • vol. 161, pp. 328. 1986.
    • Y. T. Adler, F. S. Alcorn, and J. R. Charters, "Computerized digital radiography in the study of breast diseases," Radial, vol. 161, pp. 328. 1986.
    • Radial
    • Adler, Y.T.1    Alcorn, F.S.2    Charters, J.R.3
  • 5
    • 0023110092 scopus 로고    scopus 로고
    • Direct radiographie magnification with computed radiography
    • vol. 148, no. 3, pp. 569-573, 1987.
    • Y. Nakano, T. Hiraoka, and K. Togashi, "Direct radiographie magnification with computed radiography," Am. J. Radiai, vol. 148, no. 3, pp. 569-573, 1987.
    • Am. J. Radiai
    • Nakano, Y.1    Hiraoka, T.2    Togashi, K.3
  • 6
    • 0025188835 scopus 로고    scopus 로고
    • A time-delay intégra tion charge-coupled device camera for slot-scanned digital radiography
    • vol. 17, no. 5, pp. 876-886, 1990.
    • D. W. Holdsworth, R. K. Gerson, and A. Fenster, "A time-delay intégra tion charge-coupled device camera for slot-scanned digital radiography," Med. Phys.. vol. 17, no. 5, pp. 876-886, 1990.
    • Med. Phys..
    • Holdsworth, D.W.1    Gerson, R.K.2    Fenster, A.3
  • 8
    • 0003679027 scopus 로고    scopus 로고
    • 2nd ed. New York: McGraw-Hill, pp. 9-50, 1988.
    • S. M. Sze, VLSI Technology, 2nd ed. New York: McGraw-Hill, pp. 9-50, 1988.
    • VLSI Technology
    • Sze, S.M.1
  • 9
    • 0026439069 scopus 로고    scopus 로고
    • Demonstration of megavoltagc and diagnostic X-ray imaging with hydrogenated amorphous silicon arrays
    • vol. 19, no. 6, pp. 1455-1466, 1992.
    • L. E. Antonuk, J. Boundry, W. Huang, D. L. McShan, E. J. Morton, and J. Yorkston, "Demonstration of megavoltagc and diagnostic X-ray imaging with hydrogenated amorphous silicon arrays," Med. Phys., vol. 19, no. 6, pp. 1455-1466, 1992.
    • Med. Phys.
    • Antonuk, L.E.1    Boundry, J.2    Huang, W.3    McShan, D.L.4    Morton, E.J.5    Yorkston, J.6
  • 10
    • 0000159826 scopus 로고    scopus 로고
    • Large area amorphous silicon photodiode arrays for radiotherapy and diagnostic imaging
    • vol. A- 310, pp. 460-464, 1991.
    • [101 L. E. Antonuk, J. Yorkston, J. Boundry, M. J. Longo, and R. A. Street, "Large area amorphous silicon photodiode arrays for radiotherapy and diagnostic imaging," NucL Insîr. Meth., vol. A-310, pp. 460-464, 1991.
    • NucL Insîr. Meth.
    • Antonuk, L.E.1    Yorkston, J.2    Boundry, J.3    Longo, M.J.4    Street, R.A.5
  • 11
    • 0025845656 scopus 로고    scopus 로고
    • X-Ray imaging using amorphous selenium: A photoinduced discharge readout method for digital mainmography
    • vol. 18, pp. 421-431, 1991.
    • J. A. Rowlands. D. M. Hunter, and N. Araj, "X-Ray imaging using amorphous selenium: A photoinduced discharge readout method for digital mainmography," Med. Phys., vol. 18, pp. 421-431, 1991.
    • Med. Phys.
    • Rowlands, J.A.1    Hunter, D.M.2    Araj, N.3
  • 12
    • 84953675426 scopus 로고    scopus 로고
    • Development of a digital mammography system
    • vol. 914, pp. 182 187, 1988.
    • M. J. Yaffe et ai, "Development of a digital mammography system," SPIE Proc., vol. 914, pp. 182 187, 1988.
    • SPIE Proc.
    • Yaffe, M.J.1
  • 13
    • 84957282200 scopus 로고    scopus 로고
    • Digital slot scan mammography using CCD's
    • 19, vol. 767, pp. 102-108.
    • R. S. Nelson, "Digital slot scan mammography using CCD's." in Proc. SPIE. 19, vol. 767, pp. 102-108.
    • Proc. SPIE.
    • Nelson, R.S.1
  • 14
    • 0026963713 scopus 로고    scopus 로고
    • Operational characteristics and potential of scientific charge coupled devices in X-ray imaging applications
    • 19, vol. 1655, pp. 85-91.
    • A. Karellas, H. Liu, and L. Harris, ''Operational characteristics and potential of scientific charge coupled devices in X-ray imaging applications," in Proc. SPIE, Electron Tubes and Image Intenslers, 19, vol. 1655, pp. 85-91.
    • Proc. SPIE, Electron Tubes and Image Intenslers
    • Karellas, A.1    Liu, H.2    Harris, L.3
  • 15
    • 0026739562 scopus 로고    scopus 로고
    • Chargecoupled device detector: Performance considerations and potential for mammographie imaging
    • vol. 19, no. 4, pp. 1015-1023, 1992.
    • A. Karellas, L. Harris, H. Liu, M. A. Dayis, and C. J. D'Orsi, "Chargecoupled device detector: Performance considerations and potential for mammographie imaging," Med. Phys.. vol. 19, no. 4, pp. 1015-1023, 1992.
    • Med. Phys..
    • Karellas, A.1    Harris, L.2    Liu, H.3    Dayis, M.A.4    D'Orsi, C.J.5
  • 16
    • 0027649738 scopus 로고    scopus 로고
    • Imaging of radionuclide emissions with a low noise charge coupled device
    • vol. 40, no. 4, pp. 979-982, 1993.
    • A. Karellas, H. Liu, and A. B. Brill, "Imaging of radionuclide emissions with a low noise charge coupled device," IEEE Trans. Nucl. Sei., vol. 40, no. 4, pp. 979-982, 1993.
    • IEEE Trans. Nucl. Sei.
    • Karellas, A.1    Liu, H.2    Brill, A.B.3
  • 17
    • 0027803033 scopus 로고    scopus 로고
    • Optical properties of fiber tapers and their impact on the performance of a fiberoptically coupled CCD X-ray imaging system
    • vol. 1894, pp. 136-147, 1993.
    • H. Liu, A. Karellas, L. Harris, and C. J. D'Orsi, "Optical properties of fiber tapers and their impact on the performance of a fiberoptically coupled CCD X-ray imaging system," in Proc. SPIE. vol. 1894, pp. 136-147, 1993.
    • Proc. SPIE.
    • Liu, H.1    Karellas, A.2    Harris, L.3    D'Orsi, C.J.4
  • 18
    • 0028494009 scopus 로고    scopus 로고
    • Lesion detectability considerations for an optically coupled CCD X-ray imaging system
    • vol. 41, no. 4, pp. 1506-1509, Aug. 1994.
    • H. Liu, A. Karellas, S. C. Moore, and L. J. Harris, "Lesion detectability considerations for an optically coupled CCD X-ray imaging system," IEEE Trans. Nucl. Sei., vol. 41, no. 4, pp. 1506-1509, Aug. 1994.
    • IEEE Trans. Nucl. Sei.
    • Liu, H.1    Karellas, A.2    Moore, S.C.3    Harris, L.J.4
  • 19
    • 0028070545 scopus 로고    scopus 로고
    • Different methods to calculate lens coupling efficiency in an optically coupled CCD X-ray imaging system
    • vol. 21, no. 7, pp. 1193-1195, July 1994.
    • H. Liu, A. Karellas, and L. Harris, "Different methods to calculate lens coupling efficiency in an optically coupled CCD X-ray imaging system," Med. Phvs., vol. 21, no. 7, pp. 1193-1195, July 1994.
    • Med. Phvs.
    • Liu, H.1    Karellas, A.2    Harris, L.3
  • 20
    • 0028750790 scopus 로고    scopus 로고
    • Signal-to-noise ratio analysis of the optically coupled CCD X-ray imaging system
    • vol. 2132, pp. 301-308, June 1994.
    • H. Liu, A. Karellas, L. Harris, and G. D. D'Orsi, "Signal-to-noise ratio analysis of the optically coupled CCD X-ray imaging system," in Proc. SPIE. vol. 2132, pp. 301-308, June 1994.
    • Proc. SPIE.
    • Liu, H.1    Karellas, A.2    Harris, L.3    D'Orsi, G.D.4
  • 21
    • 0029452628 scopus 로고    scopus 로고
    • Large-field high-spatial resolution digital X-ray mammography
    • vol. 2390, pp. 110-115, 1994.
    • _, "Large-field high-spatial resolution digital X-ray mammography," in Proc. SPIE, vol. 2390, pp. 110-115, 1994.
    • Proc. SPIE
  • 23
    • 84938472902 scopus 로고    scopus 로고
    • Whole breast digital mammography: Initial results with a small field image stitching approach
    • (Abstract) vol. 21, no. 6, pp. 875, June 1994.
    • J. M. Tran, M. P. Andre, B. A. Spivey, and R. Bible, "Whole breast digital mammography: Initial results with a small field image stitching approach," (Abstract), Med. Phys., vol. 21, no. 6, pp. 875, June 1994.
    • Med. Phys.
    • Tran, J.M.1    Andre, M.P.2    Spivey, B.A.3    Bible, R.4
  • 24
    • 4244154615 scopus 로고    scopus 로고
    • Tube potential, focal spot, radiation output and HVL measurements on screen-film mammography units
    • G. T. Barnes and G. D. Frey, Eds. Madison, WI: Medical Physics, 1991, pp. 67-113.
    • G. T. Barnes, "Tube potential, focal spot, radiation output and HVL measurements on screen-film mammography units," in Screen-Film Mammography, G. T. Barnes and G. D. Frey, Eds. Madison, WI: Medical Physics, 1991, pp. 67-113.
    • Screen-Film Mammography
    • Barnes, G.T.1
  • 25
    • 0017877595 scopus 로고    scopus 로고
    • The intensity of scattered radiation in mammography
    • vol. 125, pp. 243-247. Jan. 1978.
    • G. T. Barnes and A. Brezovicli, "The intensity of scattered radiation in mammography," Radial., vol. 125, pp. 243-247. Jan. 1978.
    • Radial.
    • Barnes, G.T.1    Brezovicli, A.2
  • 26
    • 0020658505 scopus 로고    scopus 로고
    • Coherent scatter in diagnostic radiology
    • vol. 10. no. 1, pp. 40 50, Jan./Feb. 1983.
    • P. C. Johns and M. J. Yaffe, "Coherent scatter in diagnostic radiology," Med. Phys., vol. 10. no. 1, pp. 40 50, Jan./Feb. 1983.
    • Med. Phys.
    • Johns, P.C.1    Yaffe, M.J.2
  • 28
    • 0002553479 scopus 로고    scopus 로고
    • Contrast and grid performance in mammography
    • G. T. Barncs and G. D. Frey, Eds. Madison. WI: Medical Physics, 1991, pp. 116-134.
    • A. J. Wagner, "Contrast and grid performance in mammography," in Screen-Film Mammography, G. T. Barncs and G. D. Frey, Eds. Madison. WI: Medical Physics, 1991, pp. 116-134.
    • Screen-Film Mammography
    • Wagner, A.J.1
  • 29
    • 0025393018 scopus 로고    scopus 로고
    • Technologic improvements in screen-film mammography
    • vol. 174, no. 3, pp. 628-637, Mar. 1990.
    • A. G. Haus, "Technologic improvements in screen-film mammography," Radial, vol. 174, no. 3, pp. 628-637, Mar. 1990.
    • Radial
    • Haus, A.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.