메뉴 건너뛰기




Volumn 23, Issue 4, 1996, Pages 525-532

A radioimmunoimaging and MIRD dosimetry treatment planning program for radioimmunotherapy

Author keywords

Dosimetry; MIRD; Monoclonal antibodies; Radioimmunoimaging; Radioimmunotherapy; Treatment planning

Indexed keywords

IODINE 131; MONOCLONAL ANTIBODY;

EID: 0030152864     PISSN: 09698051     EISSN: None     Source Type: Journal    
DOI: 10.1016/0969-8051(96)00036-4     Document Type: Article
Times cited : (44)

References (45)
  • 1
    • 85030203277 scopus 로고
    • A revised dosimetric model of the head and brain
    • 1. Bolch W. E., and Poston J. W., Sr. (1995) A revised dosimetric model of the head and brain. J. Nucl. Med. 36, 85P.
    • (1995) J. Nucl. Med. , vol.36
    • Bolch, W.E.1    Poston, J.W.2
  • 3
    • 0018774762 scopus 로고
    • Calculating dose from remaining body activity: A comparison of two methods
    • 3. Coffey J. L. and Watson E. E. (1979) Calculating dose from remaining body activity: A comparison of two methods. Med. Phys. 6, 307-308.
    • (1979) Med. Phys. , vol.6 , pp. 307-308
    • Coffey, J.L.1    Watson, E.E.2
  • 4
    • 0002704091 scopus 로고
    • Quantitative pharmacokinetics of radiolabeled monoclonal antibodies for imaging and therapy in patients
    • (Edited by Srivastava S. C.), Plenum Press, New York
    • 4. DeNardo G. L., DeNardo S. J., Macey D. J. and Mills S. L. (1988) Quantitative pharmacokinetics of radiolabeled monoclonal antibodies for imaging and therapy in patients. In Radiolabeled Monoclonal Antibodies for Imaging and Therapy (Edited by Srivastava S. C.), pp. 293-310. Plenum Press, New York.
    • (1988) Radiolabeled Monoclonal Antibodies for Imaging and Therapy , pp. 293-310
    • DeNardo, G.L.1    DeNardo, S.J.2    Macey, D.J.3    Mills, S.L.4
  • 10
    • 0012082812 scopus 로고
    • Validation of nuclear quantitation of tumor size and I-131 amount in an Alderson phantom by planar imaging
    • 10. DeNardo G. L., Shen S., DeNardo S. J., Liao S. K., Yu S. and Macey D. J. (1992) Validation of nuclear quantitation of tumor size and I-131 amount in an Alderson phantom by planar imaging. J. Nucl. Med. 33, 925.
    • (1992) J. Nucl. Med. , vol.33 , pp. 925
    • DeNardo, G.L.1    Shen, S.2    DeNardo, S.J.3    Liao, S.K.4    Yu, S.5    Macey, D.J.6
  • 16
    • 0024403276 scopus 로고
    • Preliminary validation of the opposing view method for quantitative gamma camera imaging
    • 16. Eary J. F., Applebaum F. L., Durack L. and Brown P. (1989) Preliminary validation of the opposing view method for quantitative gamma camera imaging. Med. Phys. 16, 382-387.
    • (1989) Med. Phys. , vol.16 , pp. 382-387
    • Eary, J.F.1    Applebaum, F.L.2    Durack, L.3    Brown, P.4
  • 18
    • 0028946465 scopus 로고
    • Validation of a dose-point kernel convolution technique for internal dosimetry
    • 18. Giap H. B., Macey D. J., Bayouth J. E. and Boyer A. L. (1995) Validation of a dose-point kernel convolution technique for internal dosimetry. Phys. Med. Biol. 40, 365-381.
    • (1995) Phys. Med. Biol. , vol.40 , pp. 365-381
    • Giap, H.B.1    Macey, D.J.2    Bayouth, J.E.3    Boyer, A.L.4
  • 19
    • 0012050093 scopus 로고
    • Determination of organ volume with SPECT
    • 19. Glickman S. (1987) Determination of organ volume with SPECT. Proc. SPIE 767, 406-410.
    • (1987) Proc. SPIE , vol.767 , pp. 406-410
    • Glickman, S.1
  • 21
    • 0022746291 scopus 로고
    • Automated body contour detection in SPECT: Effects on quantitative studies
    • 21. Hosoba M., Wani H., Toyama H., Murata H., and Tanaka E. (1986) Automated body contour detection in SPECT: Effects on quantitative studies. J. Nucl. Med. 27, 1184-1191.
    • (1986) J. Nucl. Med. , vol.27 , pp. 1184-1191
    • Hosoba, M.1    Wani, H.2    Toyama, H.3    Murata, H.4    Tanaka, E.5
  • 22
    • 0027133504 scopus 로고
    • 131I radiolabeled antibody uptake in liver, spleen and whole body
    • 131I radiolabeled antibody uptake in liver, spleen and whole body. Med. Phys. 20, 1667-1674.
    • (1993) Med. Phys. , vol.20 , pp. 1667-1674
    • Johnson, T.K.1    Colby, S.B.2
  • 23
    • 0026010139 scopus 로고
    • SPECT volume quantitation: Influence of spatial resolution, source size and shape, and voxel size
    • 23. King M. A., Long D. T. and Brill A. B. (1991) SPECT volume quantitation: Influence of spatial resolution, source size and shape, and voxel size. Med. Phys. 18, 1016-1024.
    • (1991) Med. Phys. , vol.18 , pp. 1016-1024
    • King, M.A.1    Long, D.T.2    Brill, A.B.3
  • 25
    • 0027294740 scopus 로고
    • An overview of imaging techniques and physical aspects of treatment planning in radioimmunotherapy
    • 25. Leichner P. K., Koral K. F., Jaszczak R. J., Green A. J., Chen G. T. Y. and Roesek J. C. (1993) An overview of imaging techniques and physical aspects of treatment planning in radioimmunotherapy. Med. Phys. 20, 569-577.
    • (1993) Med. Phys. , vol.20 , pp. 569-577
    • Leichner, P.K.1    Koral, K.F.2    Jaszczak, R.J.3    Green, A.J.4    Chen, G.T.Y.5    Roesek, J.C.6
  • 26
    • 0026755434 scopus 로고
    • The enhancement of radiotherapy verification images by an automated edge detection technique
    • 26. Leszczynski K. W., Shalev S. and Cosby N. S. (1992) The enhancement of radiotherapy verification images by an automated edge detection technique. Med. Phys. 19, 611-621.
    • (1992) Med. Phys. , vol.19 , pp. 611-621
    • Leszczynski, K.W.1    Shalev, S.2    Cosby, N.S.3
  • 27
    • 0003562301 scopus 로고
    • revised. Society of Nuclear Medicine, New York
    • 27. Loevinger R. and Berman M. (1976) MIRD Pamphlet No. 1, revised. Society of Nuclear Medicine, New York.
    • (1976) MIRD Pamphlet , vol.1
    • Loevinger, R.1    Berman, M.2
  • 28
    • 0026632674 scopus 로고
    • Comparative evaluation of image segmentation methods for volume quantitation in SPECT
    • 28. Long D. T., King M. A. and Sheehan J. (1992) Comparative evaluation of image segmentation methods for volume quantitation in SPECT. Med. Phys. 19, 483-489.
    • (1992) Med. Phys. , vol.19 , pp. 483-489
    • Long, D.T.1    King, M.A.2    Sheehan, J.3
  • 29
    • 0023852161 scopus 로고
    • Comparison of three boundary detection methods for SPECT using Compton scatter photons
    • 29. Macey D. J., DeNardo G. L. and DeNardo S. J. (1988) Comparison of three boundary detection methods for SPECT using Compton scatter photons. J. Nucl. Med. 29, 203-207.
    • (1988) J. Nucl. Med. , vol.29 , pp. 203-207
    • Macey, D.J.1    DeNardo, G.L.2    DeNardo, S.J.3
  • 31
    • 0028801340 scopus 로고
    • Improved conjugate view quantification of I-131 by subtraction of scatter and septal penetration events with a triple energy window method
    • 31. Macey D. J., Grant E. S., Bayouth J. E., Giap H. B., Danna S. J., Sirisriro R. and Podoloff D.A. (1995) Improved conjugate view quantification of I-131 by subtraction of scatter and septal penetration events with a triple energy window method. Med. Phys. 22, 1637-1644.
    • (1995) Med. Phys. , vol.22 , pp. 1637-1644
    • Macey, D.J.1    Grant, E.S.2    Bayouth, J.E.3    Giap, H.B.4    Danna, S.J.5    Sirisriro, R.6    Podoloff, D.A.7
  • 32
    • 0019952520 scopus 로고
    • Absolute quantitation of radiotracer uptake in the lungs using a gamma camera
    • 32. Macey D. J. and Marshall R. J. (1982) Absolute quantitation of radiotracer uptake in the lungs using a gamma camera. J. Nucl. Med. 23, 731-733.
    • (1982) J. Nucl. Med. , vol.23 , pp. 731-733
    • Macey, D.J.1    Marshall, R.J.2
  • 34
    • 0023812469 scopus 로고
    • Optimum processing protocols for volume determination of the liver and spleen from SPECT imaging with technetium-99m sulfur colloid
    • 34. Mut F., Glickman S., Marciano D. and Hawkins R. A. (1988) Optimum processing protocols for volume determination of the liver and spleen from SPECT imaging with technetium-99m sulfur colloid. J. Nucl. Med. 29, 1768-1775.
    • (1988) J. Nucl. Med. , vol.29 , pp. 1768-1775
    • Mut, F.1    Glickman, S.2    Marciano, D.3    Hawkins, R.A.4
  • 36
    • 0025144572 scopus 로고
    • Treatment planning for internal radionuclide therapy: Three-dimensional dosimetry for nonuniformly distributed radionuclides
    • 36. Sgouros G., Barest G., Thekkumthala J., Chiu C., Mohan R., Bigler R. E. and Zanzonico P. B. (1990) Treatment planning for internal radionuclide therapy: Three-dimensional dosimetry for nonuniformly distributed radionuclides. J. Nucl. Med. 31, 1884-1891.
    • (1990) J. Nucl. Med. , vol.31 , pp. 1884-1891
    • Sgouros, G.1    Barest, G.2    Thekkumthala, J.3    Chiu, C.4    Mohan, R.5    Bigler, R.E.6    Zanzonico, P.B.7
  • 38
    • 0027937092 scopus 로고
    • Quantitative bremsstrahlung imaging of yttrium-90 using a Wiener filter
    • 38. Shen S., DeNardo G. L. and DeNardo S. J. (1994) Quantitative bremsstrahlung imaging of yttrium-90 using a Wiener filter. Med. Phys. 21, 1409-1417.
    • (1994) Med. Phys. , vol.21 , pp. 1409-1417
    • Shen, S.1    DeNardo, G.L.2    DeNardo, S.J.3
  • 40
    • 0023919512 scopus 로고
    • Conjugate view gamma camera method for estimating tumor uptake of iodine-131 Metaiodobenzylguanidine
    • 40. Shulkin B. L., Sisson J. C., Koral K. F., Shapiro B., Wang X. and Johnson J. ( 1988) Conjugate view gamma camera method for estimating tumor uptake of iodine-131 Metaiodobenzylguanidine. J. Nucl. Med. 29, 542-548.
    • (1988) J. Nucl. Med. , vol.29 , pp. 542-548
    • Shulkin, B.L.1    Sisson, J.C.2    Koral, K.F.3    Shapiro, B.4    Wang, X.5    Johnson, J.6
  • 42
    • 0012073044 scopus 로고
    • Oak Ridge Associated Universities, Oak Ridge, Tennessee
    • 42. Stabin M., et al. (1994) MIRDOSE 3. Oak Ridge Associated Universities, Oak Ridge, Tennessee.
    • (1994) MIRDOSE , vol.3
    • Stabin, M.1
  • 43
    • 0017098356 scopus 로고
    • In vivo quantitation of lesion radioactivity using external counting methods
    • 43. Thomas S. R., Maxon H. R. and Kereiakes J. G. (1976) In vivo quantitation of lesion radioactivity using external counting methods. Med. Phys. 3, 253-255.
    • (1976) Med. Phys. , vol.3 , pp. 253-255
    • Thomas, S.R.1    Maxon, H.R.2    Kereiakes, J.G.3
  • 44
  • 45
    • 0021720579 scopus 로고
    • Radionuclide selection and model absorbed close calculations for radiolabeled tumor associated antibodies
    • 45. Wessels B. W. and Rogus R. D. (1984) Radionuclide selection and model absorbed close calculations for radiolabeled tumor associated antibodies. Med. Phys. 11, 638-645.
    • (1984) Med. Phys. , vol.11 , pp. 638-645
    • Wessels, B.W.1    Rogus, R.D.2