메뉴 건너뛰기




Volumn 14, Issue 3, 1996, Pages 186-198

Multi-cell concept for simulating fires in big enclosures using a zone model

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTATIONAL FLUID DYNAMICS; COMPUTER SIMULATION; FLOW PATTERNS; MATHEMATICAL MODELS; MICROSCOPIC EXAMINATION; PHYSICAL PROPERTIES; SMOKE; TEMPERATURE; TEMPERATURE DISTRIBUTION;

EID: 0030149847     PISSN: 07349041     EISSN: None     Source Type: Journal    
DOI: 10.1177/073490419601400302     Document Type: Article
Times cited : (20)

References (13)
  • 1
    • 5844282946 scopus 로고
    • Comparison of Full-Scale Fire Tests and a Computer Fire Model of Several Smoke Ejection Experiments
    • National Institute of Standard and Technology, Gaithersburg, MD
    • Braun, E., D. L. Lowe, W. W. Jones, R Tatem, J. Bailey and R. Carey. 1992. "Comparison of Full-Scale Fire Tests and a Computer Fire Model of Several Smoke Ejection Experiments," NISTIR Report 4961, National Institute of Standard and Technology, Gaithersburg, MD.
    • (1992) NISTIR Report 4961
    • Braun, E.1    Lowe, D.L.2    Jones, W.W.3    Tatem, R.4    Bailey, J.5    Carey, R.6
  • 2
    • 5844262603 scopus 로고
    • Smoke Spread Experiments in Large Rooms. Experimental Results and Numerical Simulation
    • Swedish Natural Testing and Research Institute, Sweden
    • Söderbom, J. 1992. "Smoke Spread Experiments in Large Rooms. Experimental Results and Numerical Simulation," SP Report 1992, Swedish Natural Testing and Research Institute, Sweden.
    • (1992) SP Report 1992
    • Söderbom, J.1
  • 3
    • 0002422209 scopus 로고
    • Verification of a Model of Fire and Smoke Transport
    • Peacock, R. D., W. W. Jones and R. W. Bukowski. 1993. "Verification of a Model of Fire and Smoke Transport," Fire Safety Journal, 21(1):89-129.
    • (1993) Fire Safety Journal , vol.21 , Issue.1 , pp. 89-129
    • Peacock, R.D.1    Jones, W.W.2    Bukowski, R.W.3
  • 5
    • 85033029840 scopus 로고    scopus 로고
    • Improved Fire Safety System in Developing Countries
    • Tokyo, Japan, (October 17)
    • Chow, W. K. 1994. "Fire Aspects for Atrium Building in Hong Kong," 7th International Research and Training Seminar on Regional Development Planning for Disaster Prevention, "Improved Fire Safety System in Developing Countries," United Nations Centre for Regional Development, Tokyo, Japan, (October 17).
    • United Nations Centre for Regional Development
  • 6
    • 34547238708 scopus 로고
    • CFAST, the Consolidated Model of Fire Growth and Smoke Transport
    • National Institute of Standards and Technology, Gaithersburg, MD
    • Peacock, R. D., G. P. Forney, P. Reneke, R. Portier and W. W. Jones. 1993. "CFAST, the Consolidated Model of Fire Growth and Smoke Transport," NIST Technical Note 1299, National Institute of Standards and Technology, Gaithersburg, MD.
    • (1993) NIST Technical Note 1299
    • Peacock, R.D.1    Forney, G.P.2    Reneke, P.3    Portier, R.4    Jones, W.W.5
  • 7
    • 84965695258 scopus 로고
    • Modelling Smoke Movement through Compartmented Structure
    • March/April
    • Jones, W. W. 1993. "Modelling Smoke Movement through Compartmented Structure," Journal of Fire Science, 11(March/April):172-183.
    • (1993) Journal of Fire Science , vol.11 , pp. 172-183
    • Jones, W.W.1
  • 8
    • 6244237837 scopus 로고
    • Guide for Smoke Management Systems in Malls, Atria and Large Areas
    • Quincy, MA
    • NFPA 92B. 1991. "Guide for Smoke Management Systems in Malls, Atria and Large Areas," National Fire Protection, Quincy, MA.
    • (1991) National Fire Protection
  • 9
    • 0003864972 scopus 로고
    • Method of Predicting Smoke Movement in Atria with Application to Smoke Management
    • National Institute of Standard and Technology, Gaithersburg, MD
    • Klote, J. H. 1994. "Method of Predicting Smoke Movement in Atria with Application to Smoke Management," NISTIR Report 5516, National Institute of Standard and Technology, Gaithersburg, MD.
    • (1994) NISTIR Report 5516
    • Klote, J.H.1
  • 10
    • 0024875506 scopus 로고
    • Comparisons of NBS/Harvard VI Simulations and Data from All Runs of a Full-Scale Multi-Room Fire Test Program
    • Rockett, J, A., M. Morita and L. Y. Cooper. 1989. "Comparisons of NBS/Harvard VI Simulations and Data from All Runs of a Full-Scale Multi-Room Fire Test Program," Fire Safety Journal, 15(2):115-169.
    • (1989) Fire Safety Journal , vol.15 , Issue.2 , pp. 115-169
    • Rockett, J.A.1    Morita, M.2    Cooper, L.Y.3
  • 11
    • 84970121969 scopus 로고
    • Use of Computational Fluid Dynamics for Simulating Enclosure Fire
    • Chow, W. K. 1995. "Use of Computational Fluid Dynamics for Simulating Enclosure Fire," Journal of Fire Science, 13(4):300-334.
    • (1995) Journal of Fire Science , vol.13 , Issue.4 , pp. 300-334
    • Chow, W.K.1
  • 12
    • 0242450563 scopus 로고
    • Fire-Induced Flow Through Room Openings-Flow Coefficient
    • U. S. National Bureau of Standards, Gaithersburg, MD
    • Steckler, K. D., H. R. Baum and J. Q. Quintiere. 1984. "Fire-Induced Flow Through Room Openings-Flow Coefficient," NBSIR 83-2801, U. S. National Bureau of Standards, Gaithersburg, MD.
    • (1984) NBSIR 83-2801
    • Steckler, K.D.1    Baum, H.R.2    Quintiere, J.Q.3
  • 13
    • 0003582312 scopus 로고
    • Full-Scale Burning Facilities for Atrium Fire Research
    • Chow, W. K., W. Fan and L. Chen. 1993. "Full-Scale Burning Facilities for Atrium Fire Research," Fire Safety Science - in Chinese, 2(2):60-63.
    • (1993) Fire Safety Science - in Chinese , vol.2 , Issue.2 , pp. 60-63
    • Chow, W.K.1    Fan, W.2    Chen, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.