메뉴 건너뛰기




Volumn 31, Issue 3, 1996, Pages 205-214

The effect of the transverse component of the hip reaction on cement mantle stresses in a model of an implanted Exeter™ prosthesis

Author keywords

Cement mantle stresses; Embedded strain gauging; Model testing; Torsional loading; Total hip replacement; Transverse joint force

Indexed keywords

BENDING STRENGTH; EFFECTS; ELASTIC MODULI; HIP PROSTHESES; MODELS; SHEAR STRESS; STRAIN GAGES; THREE DIMENSIONAL; TORSIONAL STRESS; TRANSDUCERS;

EID: 0030147779     PISSN: 03093247     EISSN: None     Source Type: Journal    
DOI: 10.1243/03093247V313205     Document Type: Article
Times cited : (8)

References (51)
  • 1
    • 0344097815 scopus 로고
    • PhD Thesis, University of Glasgow
    • PAUL, J. P. Forces at the human hip joint, PhD Thesis, University of Glasgow, 1967, pp. 181-242.
    • (1967) Forces at the Human Hip Joint , pp. 181-242
    • Paul, J.P.1
  • 2
    • 0014746120 scopus 로고
    • Abduction forces in the one legged stance
    • McLEISH, R. D. and CHARNLEY, J. 'Abduction forces in the one legged stance', J. Biomechanics, 1970, 3, 191-209.
    • (1970) J. Biomechanics , vol.3 , pp. 191-209
    • McLeish, R.D.1    Charnley, J.2
  • 3
    • 0023681017 scopus 로고
    • Experience with the Exeter total hip replacement since 1970
    • FOWLER, J. L., GIE, G. A., LEE, A. J. C. and LING, R. S. M. 'Experience with the Exeter total hip replacement since 1970', Orthop. Clinics of N. Am., 1988, 3(19), 477-488.
    • (1988) Orthop. Clinics of N. Am. , vol.3 , Issue.19 , pp. 477-488
    • Fowler, J.L.1    Gie, G.A.2    Lee, A.J.C.3    Ling, R.S.M.4
  • 4
    • 0019044421 scopus 로고
    • Transverse load on the hip joint: A subject for further research
    • WROBLEWSKI, B. M. 'Transverse load on the hip joint: a subject for further research', Engng Medicine, 1980, 9, 163-164.
    • (1980) Engng Medicine , vol.9 , pp. 163-164
    • Wroblewski, B.M.1
  • 5
    • 0025172192 scopus 로고
    • Trends of mechanical consequences and modelling of a fibrous _ membrane around femoral hip prostheses
    • WEINANS, H., HUISKES, R. and GROOTENBOER, H. J. 'Trends of mechanical consequences and modelling of a fibrous _ membrane around femoral hip prostheses' J. Biomechanics, 1990, 23, 991-1000.
    • (1990) J. Biomechanics , vol.23 , pp. 991-1000
    • Weinans, H.1    Huiskes, R.2    Grootenboer, H.J.3
  • 6
    • 0025495251 scopus 로고
    • Stress analysis of the proximo-medial femur after total hip replacement
    • PRENDERGAST, P. J. and TAYLOR, D. 'Stress analysis of the proximo-medial femur after total hip replacement', J. Biomed. Engng, 1990, 12, 379-382.
    • (1990) J. Biomed. Engng , vol.12 , pp. 379-382
    • Prendergast, P.J.1    Taylor, D.2
  • 8
    • 0024764167 scopus 로고
    • Effect of interface conditions on the behaviour of a Freeman hip endoprosthesis
    • YETTRAM, A. L. 'Effect of interface conditions on the behaviour of a Freeman hip endoprosthesis', J. Biomed. Engng, 1989, 11, 520-524.
    • (1989) J. Biomed. Engng , vol.11 , pp. 520-524
    • Yettram, A.L.1
  • 9
    • 0022097380 scopus 로고
    • An experimental study of femoral cement stress in total hip replacement - Influence of structural stiffness of the femoral stem
    • MILES, A. W. and DALL, D. M. 'An experimental study of femoral cement stress in total hip replacement - influence of structural stiffness of the femoral stem', Engng Medicine, 1985, 14, 133-135.
    • (1985) Engng Medicine , vol.14 , pp. 133-135
    • Miles, A.W.1    Dall, D.M.2
  • 10
    • 0023759917 scopus 로고
    • Design and fabrication of cementless hip stems
    • WALKER, P. S. and ROBERTSON, D. D. 'Design and fabrication of cementless hip stems', Clin. Orthop., 1988, 235, 25-34.
    • (1988) Clin. Orthop. , vol.235 , pp. 25-34
    • Walker, P.S.1    Robertson, D.D.2
  • 11
    • 0016881356 scopus 로고
    • Approaches to design
    • PAUL, J. P. 'Approaches to design', Proc. R. Soc. Lond. B, 1976, 192, 163-172.
    • (1976) Proc. R. Soc. Lond. B , vol.192 , pp. 163-172
    • Paul, J.P.1
  • 12
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running measured in two patients
    • BERGMANN, G., GRAICHEN, F. and ROHLMANN, A. 'Hip joint loading during walking and running measured in two patients', J. Biomechanics, 1993, 26, 969-990.
    • (1993) J. Biomechanics , vol.26 , pp. 969-990
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 14
    • 4243146163 scopus 로고
    • Hip abductor muscle force
    • MERCHANT, A. C. 'Hip abductor muscle force', J. Bone Jt Surg., 1966, 46-A, 462-476.
    • (1966) J. Bone Jt Surg. , vol.46 A , pp. 462-476
    • Merchant, A.C.1
  • 15
    • 22644447214 scopus 로고
    • Loading of hip implants by torsional moments
    • Orthopedic Research Society, Washington, D.C., February
    • BERGMANN, G., GRAICHEN, F. and ROHLMANN, A. 'Loading of hip implants by torsional moments', 38th Annual Meeting, Orthopedic Research Society, Washington, D.C., February 1992, p. 19.
    • (1992) 38th Annual Meeting , pp. 19
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 16
    • 0026034958 scopus 로고
    • Loosening of cementless femoral stems: A biomechanical analysis of immediate fixation with loading vertical, femur horizontal
    • PHILLIPS, T. W., NGUGEN, L. T. and MUNRO, S. D. 'Loosening of cementless femoral stems: a biomechanical analysis of immediate fixation with loading vertical, femur horizontal', J. Biomechanics, 1991, 24, 37-48.
    • (1991) J. Biomechanics , vol.24 , pp. 37-48
    • Phillips, T.W.1    Ngugen, L.T.2    Munro, S.D.3
  • 18
    • 0009715115 scopus 로고
    • Load simulation problems in model testing
    • edited by A. Miles and K. Tanner, Chapman and Hall, London
    • O'CONNOR, J. J. 'Load simulation problems in model testing', in Strain Measurement in Biomechanics, edited by A. Miles and K. Tanner, 1992 (Chapman and Hall, London), pp. 14-38.
    • (1992) Strain Measurement in Biomechanics , pp. 14-38
    • O'Connor, J.J.1
  • 19
    • 0026070354 scopus 로고
    • A three-dimensional non-linear finite element study of the effect of cement-prosthesis debonding in cemented femoral total hip components
    • HARRIGAN, T. P. and HARRIS, W. H. 'A three-dimensional non-linear finite element study of the effect of cement-prosthesis debonding in cemented femoral total hip components', J. Biomechanics, 1991, 24, 1047-1058.
    • (1991) J. Biomechanics , vol.24 , pp. 1047-1058
    • Harrigan, T.P.1    Harris, W.H.2
  • 20
    • 0026580011 scopus 로고
    • A finite element study of the initiation of failure of fixation in cemented femoral total hip components
    • HARRIGAN, T. P., KAREH, J. A., O'CONNOR, D. O., BURKE, D. W. and HARRIS, W. H. 'A finite element study of the initiation of failure of fixation in cemented femoral total hip components', J. Orthop. Res., 1992, 10, 134-144.
    • (1992) J. Orthop. Res. , vol.10 , pp. 134-144
    • Harrigan, T.P.1    Kareh, J.A.2    O'Connor, D.O.3    Burke, D.W.4    Harris, W.H.5
  • 21
    • 0023841498 scopus 로고
    • Global mechanical consequences of reduced cement/bone coupling rigidity in proximal femoral arthroplasty. A three dimensional finite element analysis
    • BROWN, T. D., PEDERSEN, D. R., RADIN, E. L. and ROSE, R. M. 'Global mechanical consequences of reduced cement/bone coupling rigidity in proximal femoral arthroplasty. A three dimensional finite element analysis', J. Biomechanics, 1988, 21, 115-129.
    • (1988) J. Biomechanics , vol.21 , pp. 115-129
    • Brown, T.D.1    Pedersen, D.R.2    Radin, E.L.3    Rose, R.M.4
  • 23
    • 0022886595 scopus 로고
    • Role of the collar on the femoral stem of cemented total hip replacements
    • FAGAN, M. J. and LEE, A. J. C. 'Role of the collar on the femoral stem of cemented total hip replacements', J. Biomed. Engng, 1986, 8, 295-304.
    • (1986) J. Biomed. Engng , vol.8 , pp. 295-304
    • Fagan, M.J.1    Lee, A.J.C.2
  • 24
    • 0024817347 scopus 로고
    • Non-linear three dimensional finite element analysis of a cementless hip endoprosthesis
    • TENSI, H. M., GESE, H. and ASCHERL, R., 'Non-linear three dimensional finite element analysis of a cementless hip endoprosthesis', Proc. Instn Mech. Engrs, Part H, 1989, 203(H4), 215-222.
    • (1989) Proc. Instn Mech. Engrs, Part H , vol.203 , Issue.H4 , pp. 215-222
    • Tensi, H.M.1    Gese, H.2    Ascherl, R.3
  • 26
    • 85033846399 scopus 로고
    • In-vitro stress analysis of the hip investigating the effects of joint and muscle load simulation
    • edited by J. F. Silva Gomes et al., Lisbon, 18-22 July Balkema
    • COLGAN, D., McTAGUE, D., O'DONNELL, P. and LITTLE, E. G. 'In-vitro stress analysis of the hip investigating the effects of joint and muscle load simulation', in Recent Advances in Experimental Mechanics, edited by J. F. Silva Gomes et al., Lisbon, 18-22 July 1994, pp. 1381-1386 (Balkema).
    • (1994) Recent Advances in Experimental Mechanics , pp. 1381-1386
    • Colgan, D.1    McTague, D.2    O'Donnell, P.3    Little, E.G.4
  • 27
    • 0016568392 scopus 로고
    • Three dimensional strain rosettes: Pattern selection and performance evaluation
    • ROSSETTO, S., BRAY, A. and LEVI, R. 'Three dimensional strain rosettes: pattern selection and performance evaluation', Expl Mechanics, 1975, 10(15), 375-381.
    • (1975) Expl Mechanics , vol.10 , Issue.15 , pp. 375-381
    • Rossetto, S.1    Bray, A.2    Levi, R.3
  • 30
    • 0020290796 scopus 로고
    • A method of embedding strain gauges into an epoxy model with proposed application to the tibial component of the Geomedic knee joint
    • Haifa, Israel
    • LITTLE, E. G. 'A method of embedding strain gauges into an epoxy model with proposed application to the tibial component of the Geomedic knee joint', Proceedings of 7th International Conference on Experimental Stress Analysis, Haifa, Israel, 1982, pp. 202-203.
    • (1982) Proceedings of 7th International Conference on Experimental Stress Analysis , pp. 202-203
    • Little, E.G.1
  • 31
    • 84981565991 scopus 로고
    • Assessment of strain gradients affecting the performance of 3D strain rosettes - Relevant to the analysis of cement mantle strains in total hip replacements
    • McTAGUE, D. and LITTLE, E. G. 'Assessment of strain gradients affecting the performance of 3D strain rosettes - relevant to the analysis of cement mantle strains in total hip replacements', Strain, 1992, 28, 143-151.
    • (1992) Strain , vol.28 , pp. 143-151
    • McTague, D.1    Little, E.G.2
  • 32
    • 2642595986 scopus 로고
    • The effects of torsion on the performance of 3D strain rosettes: With application to assessment of strains in models of a cement mantle supporting a femoral hip replacement
    • edited by E. G. Little, Limerick, 4-6 September Elsevier
    • McTAGUE, D., MURPHY, E. and LITTLE, E. G. 'The effects of torsion on the performance of 3D strain rosettes: with application to assessment of strains in models of a cement mantle supporting a femoral hip replacement', in Experimental Mechanics: Technology Transfer between High Tech Engineering and Biomechanics, edited by E. G. Little, Limerick, 4-6 September 1992, pp. 423-432 (Elsevier).
    • (1992) Experimental Mechanics: Technology Transfer between High Tech Engineering and Biomechanics , pp. 423-432
    • McTague, D.1    Murphy, E.2    Little, E.G.3
  • 33
    • 0020203982 scopus 로고
    • Effects of self heating when using continuous bridge voltages for the strain gauging of epoxy models
    • LITTLE, E. G. 'Effects of self heating when using continuous bridge voltages for the strain gauging of epoxy models', Strain, 1982, 18, 131-135.
    • (1982) Strain , vol.18 , pp. 131-135
    • Little, E.G.1
  • 34
    • 0040493205 scopus 로고
    • Errors and uncertainties in strain measurement
    • edited by A. L. Window and G. S. Holister, Elsevier Applied Science, London
    • POPLE, J. 'Errors and uncertainties in strain measurement', in Strain Gauge Technology, edited by A. L. Window and G. S. Holister, 1982 (Elsevier Applied Science, London).
    • (1982) Strain Gauge Technology
    • Pople, J.1
  • 36
    • 4243082035 scopus 로고
    • Three-dimensional strain rosettes from an analysis of the Geomedic knee prosthesis and underlying cement fixation
    • edited by T. E. Hyde and E. Ollerton, Elsevier Applied Science, Barking
    • LITTLE, E. G. 'Three-dimensional strain rosettes from an analysis of the Geomedic knee prosthesis and underlying cement fixation', in Applied Stress Analysis, edited by T. E. Hyde and E. Ollerton, 1990 (Elsevier Applied Science, Barking), pp. 140-149.
    • (1990) Applied Stress Analysis , pp. 140-149
    • Little, E.G.1
  • 37
    • 0016801068 scopus 로고
    • The elastic and ultimate properties of compact bone tissue
    • REILLY, D. T. and BURSTEIN, A. H. 'The elastic and ultimate properties of compact bone tissue', J. Biomechanics, 1975, 8, 393-405.
    • (1975) J. Biomechanics , vol.8 , pp. 393-405
    • Reilly, D.T.1    Burstein, A.H.2
  • 39
    • 0017154560 scopus 로고
    • The femoral stem/ cement interface in total hip replacement
    • FORNASIER, V. L. and CAMERON, H. Y. 'The femoral stem/ cement interface in total hip replacement', Clin. Orthop., 1976, 116, 248-252.
    • (1976) Clin. Orthop. , vol.116 , pp. 248-252
    • Fornasier, V.L.1    Cameron, H.Y.2
  • 40
    • 0028429672 scopus 로고
    • A review of joint and muscle load simulation relevant to in-vitro stress analysis of the hip
    • May
    • COLGAN, D., TRENCH, P., SLEMON, D., McTAGUE, D., FINLAY, J. B., O'DONNELL, P. and LITTLE, E. G. 'A review of joint and muscle load simulation relevant to in-vitro stress analysis of the hip', Strain, May 1994, 47-61.
    • (1994) Strain , pp. 47-61
    • Colgan, D.1    Trench, P.2    Slemon, D.3    McTague, D.4    Finlay, J.B.5    O'Donnell, P.6    Little, E.G.7
  • 41
    • 0002896423 scopus 로고
    • In-vivo investigations on the mechanical function of the tractus iliotibialis
    • edited by R. Huiskes, D. Van Campen and J. Dewijn, Martinus Nijhoff, The Hague
    • JACOB, H. A. C., HUGGLER, A. H. and RUTTIMAN, B. 'In-vivo investigations on the mechanical function of the tractus iliotibialis', in Biomechanics: Principles and Applications, edited by R. Huiskes, D. Van Campen and J. Dewijn, 1982 (Martinus Nijhoff, The Hague), pp. 161-167.
    • (1982) Biomechanics: Principles and Applications , pp. 161-167
    • Jacob, H.A.C.1    Huggler, A.H.2    Ruttiman, B.3
  • 42
    • 0011826267 scopus 로고
    • Uncertainties and errors in magnitude and direction of principal strains evaluated with three-dimensional strain rosettes
    • Udine, Italy
    • ROSSETTO, S., BRAY, A. and LEVI, R. 'Uncertainties and errors in magnitude and direction of principal strains evaluated with three-dimensional strain rosettes', 5th International Conference on Experimental Stress Analysis, Udine, Italy, 1974, pp. 1.153-1.161.
    • (1974) 5th International Conference on Experimental Stress Analysis
    • Rossetto, S.1    Bray, A.2    Levi, R.3
  • 43
    • 85033870313 scopus 로고
    • ANSI/ASME, PTC 19.1
    • ANSI/ASME, PTC 19.1, Measurement uncertainty, 1985, Part 1, pp. 57-60.
    • (1985) Measurement Uncertainty , Issue.1 PART , pp. 57-60
  • 45
    • 4243189236 scopus 로고
    • An examination of femoral stem geometry in total hip replacements
    • FAGAN, M. J. and LEE, A. J. C. 'An examination of femoral stem geometry in total hip replacements', Innov. Technol. Biol. Medicine, 1988, 1(9), 30-43.
    • (1988) Innov. Technol. Biol. Medicine , vol.1 , Issue.9 , pp. 30-43
    • Fagan, M.J.1    Lee, A.J.C.2
  • 46
    • 85033854124 scopus 로고
    • Stresses in ceramic prosthetic heads under axisymmetric loading: Effect of taper friction, support conditions and spigot elasticity
    • edited by E. G. Little, Limerick, 4-6 September Elsevier.
    • DRAGONI, E., ANDRISANO, A. O. and BERTUZZI, F. 'Stresses in ceramic prosthetic heads under axisymmetric loading: effect of taper friction, support conditions and spigot elasticity', in Experimental Mechanics: Technology Transfer between High Tech Engineering and Biomechanics, edited by E. G. Little, Limerick, 4-6 September 1992, pp. 23-35 (Elsevier).
    • (1992) Experimental Mechanics: Technology Transfer between High Tech Engineering and Biomechanics , pp. 23-35
    • Dragoni, E.1    Andrisano, A.O.2    Bertuzzi, F.3
  • 47
    • 0021359644 scopus 로고
    • The influence of prosthetic stem stiffness and of a calcar collar on the stresses in the proximal end of the femur with a cemented femoral component
    • LEWIS, J. L., ASKEW, M. J., WIXON, R. L., KRAMER, G. M. and TARR, R. R. 'The influence of prosthetic stem stiffness and of a calcar collar on the stresses in the proximal end of the femur with a cemented femoral component', J. Bone Jt Surg., 1984, 66-A, 280-286.
    • (1984) J. Bone Jt Surg. , vol.66 A , pp. 280-286
    • Lewis, J.L.1    Askew, M.J.2    Wixon, R.L.3    Kramer, G.M.4    Tarr, R.R.5
  • 48
    • 0021064911 scopus 로고
    • Finite element analysis and experimental investigation in a femur with hip endoprosthesis
    • ROHLMANN, A., MOSSNER, U., BERGMANN, G. and KOLBEL, R. 'Finite element analysis and experimental investigation in a femur with hip endoprosthesis', J. Biomechanics, 1983, 16, 727-742.
    • (1983) J. Biomechanics , vol.16 , pp. 727-742
    • Rohlmann, A.1    Mossner, U.2    Bergmann, G.3    Kolbel, R.4
  • 49
    • 0018838788 scopus 로고
    • An analysis of femoral component stem design in total hip arthroplasty
    • CROWNINSHIELD, R. D., BRAND, R. A., JOHNSTON, R. C. and MILROY, J. C. 'An analysis of femoral component stem design in total hip arthroplasty', J. Bone Jt Surg., 1980, 62-A, 68-78.
    • (1980) J. Bone Jt Surg. , vol.62 A , pp. 68-78
    • Crowninshield, R.D.1    Brand, R.A.2    Johnston, R.C.3    Milroy, J.C.4
  • 50
    • 0018877406 scopus 로고
    • The effect of femoral stem cross-section geometry on cement stresses in total hip reconstruction
    • CROWNINSHIELD, R. D., BRAND, R. A., JOHNSTON, R. C. and MILROY, J. C. 'The effect of femoral stem cross-section geometry on cement stresses in total hip reconstruction', Clin. Orthop., 1980, 146, 71-77.
    • (1980) Clin. Orthop. , vol.146 , pp. 71-77
    • Crowninshield, R.D.1    Brand, R.A.2    Johnston, R.C.3    Milroy, J.C.4
  • 51
    • 0000017865 scopus 로고
    • Some fundamental aspects of human joint replacement
    • HUISKES, R. 'Some fundamental aspects of human joint replacement', Acta Orthop. Scand., Suppl., 1980, 185.
    • (1980) Acta Orthop. Scand., Suppl. , pp. 185
    • Huiskes, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.