메뉴 건너뛰기




Volumn 208, Issue 5, 1996, Pages 333-336

Simultaneous digital ICG and fluorescein angiography;Simultane digitale indocyaningrün- und fluoreszeinangiographie

Author keywords

Digital angiography; Digital image processing; Fluorescein angiography; Indocyanine green angiography; Simultaneous angiography

Indexed keywords

CONTRAST MEDIUM; DIAGNOSTIC AGENT; INDOCYANINE GREEN;

EID: 0030140860     PISSN: 00232165     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2008-1035230     Document Type: Article
Times cited : (7)

References (12)
  • 1
    • 0028934506 scopus 로고
    • Simultaneous Indocyanine green and fluorescein (SIF-) angiography
    • Bischoff P, Niederberger H, Török B, Speiser P. Simultaneous Indocyanine green and fluorescein (SIF-) angiography. Retina 1995; 15:91-99
    • (1995) Retina , vol.15 , pp. 91-99
    • Bischoff, P.1    Niederberger, H.2    Török, B.3    Speiser, P.4
  • 2
    • 0025363253 scopus 로고
    • Ein neues Laser-Scan-System für die Fernseh-Ophthalmoskopie. Erste klinische Erfahrungen auch in Verbindung mit der digitalen Bildverarbeitung
    • Fabian E, Mertz M, Hofmann H, Wertheimer R, Foos C. Ein neues Laser-Scan-System für die Fernseh-Ophthalmoskopie. Erste klinische Erfahrungen auch in Verbindung mit der digitalen Bildverarbeitung. Klin Monatsbl Augenheilkd 1990; 196:489-494
    • (1990) Klin Monatsbl Augenheilkd , vol.196 , pp. 489-494
    • Fabian, E.1    Mertz, M.2    Hofmann, H.3    Wertheimer, R.4    Foos, C.5
  • 3
    • 0015605486 scopus 로고
    • A clinical technique and apparat is for simultaneous angiography of the separate retinal and choroidal circulations
    • Flower RW, Hochheimer BF. A clinical technique and apparat is for simultaneous angiography of the separate retinal and choroidal circulations. Invest Ophthalmol Vis Sci 1973; 12:248-261
    • (1973) Invest Ophthalmol Vis Sci , vol.12 , pp. 248-261
    • Flower, R.W.1    Hochheimer, B.F.2
  • 4
    • 0027406517 scopus 로고
    • Safety considerations for simultaneous multiple wavelength exposure in scanning laser ophthalmoscopes
    • Li L, Rosenshein JS. Safety considerations for simultaneous multiple wavelength exposure in scanning laser ophthalmoscopes. Health Phys 1993; 64:170-177
    • (1993) Health Phys , vol.64 , pp. 170-177
    • Li, L.1    Rosenshein, J.S.2
  • 6
    • 0027506926 scopus 로고
    • Fluorescein and indocyanine green angiographies of central serous choroidopathy by scanning laser ophthalmoscopy
    • Scheider A, Nasemann JE, Lund OE. Fluorescein and indocyanine green angiographies of central serous choroidopathy by scanning laser ophthalmoscopy. Am J Ophthalmol 1992; 115:55-56
    • (1992) Am J Ophthalmol , vol.115 , pp. 55-56
    • Scheider, A.1    Nasemann, J.E.2    Lund, O.E.3
  • 7
    • 0026810205 scopus 로고
    • Indozyaningrünangiographie mit einem Infrarot-Scanning-Laser-Ophthalmoskop. Erste klinische Erfahrungen
    • Scheider A. Indozyaningrünangiographie mit einem Infrarot-Scanning-Laser-Ophthalmoskop. Erste klinische Erfahrungen. Ophthalmologe 1992; 89:27-33
    • (1992) Ophthalmologe , vol.89 , pp. 27-33
    • Scheider, A.1
  • 8
    • 0026597308 scopus 로고
    • Detection of subretinal neovascular membranes with indocyanine green and an infrared scanning laser ophthalmoscope
    • Scheider A, Kaboth A, Neuhauser L. Detection of subretinal neovascular membranes with indocyanine green and an infrared scanning laser ophthalmoscope. Am J Ophthalmol 1992; 113:45-51
    • (1992) Am J Ophthalmol , vol.113 , pp. 45-51
    • Scheider, A.1    Kaboth, A.2    Neuhauser, L.3
  • 10
    • 0025729244 scopus 로고
    • Retimal capillary blood flow measurement with a scanning laser ophthalmoscope. Preliminary results
    • Wolf S, Arend O, Toonen H, Bertram B, Jung F, Reim M. Retimal capillary blood flow measurement with a scanning laser ophthalmoscope. Preliminary results. Ophthalmology 1991; 98:996-1000
    • (1991) Ophthalmology , vol.98 , pp. 996-1000
    • Wolf, S.1    Arend, O.2    Toonen, H.3    Bertram, B.4    Jung, F.5    Reim, M.6
  • 11
    • 0027439366 scopus 로고
    • Retinal hemodynamics using scanning laser ophthalmoscopy and hemorheology in chronic open-angle glaucoma
    • Wolf S, Arend O, Sponsel WE, Schulte K, Cantor LB, Reim M. Retinal hemodynamics using scanning laser ophthalmoscopy and hemorheology in chronic open-angle glaucoma. Ophthalmology 1993; 100:1561-1566
    • (1993) Ophthalmology , vol.100 , pp. 1561-1566
    • Wolf, S.1    Arend, O.2    Sponsel, W.E.3    Schulte, K.4    Cantor, L.B.5    Reim, M.6
  • 12
    • 0026624898 scopus 로고
    • Confocal imaging of the fundus using a scanning laser ophthalmoscope
    • Woon WH, Fitzke FW, Bird AC, Marshall J. Confocal imaging of the fundus using a scanning laser ophthalmoscope. Br J Ophthalmol 1992; 76:470-474
    • (1992) Br J Ophthalmol , vol.76 , pp. 470-474
    • Woon, W.H.1    Fitzke, F.W.2    Bird, A.C.3    Marshall, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.