메뉴 건너뛰기




Volumn 6, Issue 3, 1996, Pages 484-494

Black blood dual phase turbo FLASH MR imaging of the heart

Author keywords

Breath hold MR imaging; Dark blood; Functional cardiac MR imaging; Segmented acquisition; Turbo FLASH

Indexed keywords

ARTICLE; BLOOD; DIASTOLE; ENDOCARDIUM; HEART; HEART VENTRICLE; HISTOLOGY; HUMAN; IMAGE ENHANCEMENT; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; PHYSIOLOGY; REFERENCE VALUE; SIGNAL PROCESSING; SYSTOLE;

EID: 0030140262     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.1880060312     Document Type: Article
Times cited : (15)

References (8)
  • 1
    • 0023762562 scopus 로고
    • Evaluation of magnetic resonance imaging for determination of left ventricular ejection fraction and comparison with angiography
    • Van Rossum AC, Visser FC, Sprenger M, Van Eenige MJ, Valk J, Roos JP. Evaluation of magnetic resonance imaging for determination of left ventricular ejection fraction and comparison with angiography. Am J Cardiol 1988; 62:628-633.
    • (1988) Am J Cardiol , vol.62 , pp. 628-633
    • Van Rossum, A.C.1    Visser, F.C.2    Sprenger, M.3    Van Eenige, M.J.4    Valk, J.5    Roos, J.P.6
  • 2
    • 0025670618 scopus 로고
    • Magnetic resonance imaging and cine computerised tomography as future tools for cardiac output measurement
    • Omvik P. Magnetic resonance imaging and cine computerised tomography as future tools for cardiac output measurement. Eur Heart J 1990; 11(Suppl I):141-143.
    • (1990) Eur Heart J , vol.11 , Issue.1 SUPPL. , pp. 141-143
    • Omvik, P.1
  • 3
    • 0028240665 scopus 로고
    • Automated myocardial edge detection from breath-hold cine-MR images: Evaluation of left ventricular volumes and mass
    • Baldy C, Douek P, Croisille P, Magnin IE, Revel D. Amiel M. Automated myocardial edge detection from breath-hold cine-MR images: evaluation of left ventricular volumes and mass. Magn Reson Imaging 1994; 12:589-598.
    • (1994) Magn Reson Imaging , vol.12 , pp. 589-598
    • Baldy, C.1    Douek, P.2    Croisille, P.3    Magnin, I.E.4    Revel, D.5    Amiel, M.6
  • 4
    • 0028185597 scopus 로고
    • Measurement of stroke volume and cardiac output within a single breathold with echo-planar MR imaging
    • Hunter GJ, Hamberg LM, Weisskoff RM, Halpern EF, Brady TJ. Measurement of stroke volume and cardiac output within a single breathold with echo-planar MR imaging. JMRI 1994; 4:51-58.
    • (1994) JMRI , vol.4 , pp. 51-58
    • Hunter, G.J.1    Hamberg, L.M.2    Weisskoff, R.M.3    Halpern, E.F.4    Brady, T.J.5
  • 6
    • 0026320313 scopus 로고
    • Fast selective black blood MR imaging
    • Edelman RR, Chien D, Kim D. Fast selective black blood MR imaging. Radiology 1991; 181:655-660.
    • (1991) Radiology , vol.181 , pp. 655-660
    • Edelman, R.R.1    Chien, D.2    Kim, D.3
  • 7
    • 0027235783 scopus 로고
    • Magnetization-prepared cardiac imaging using gradient echo acquisition
    • Liu Y, Riederer SJ, Ehman RL. Magnetization-prepared cardiac imaging using gradient echo acquisition. Magn Reson Med 1993; 30:271-275.
    • (1993) Magn Reson Med , vol.30 , pp. 271-275
    • Liu, Y.1    Riederer, S.J.2    Ehman, R.L.3
  • 8
    • 0025807054 scopus 로고
    • Quantification of and correction for left ventricular systolic long-axis shortening by magnetic resonance tissue tagging and slice isolation
    • Rogers WJ, Shapiro EP, Weiss JL, et al. Quantification of and correction for left ventricular systolic long-axis shortening by magnetic resonance tissue tagging and slice isolation. Circulation 1991; 84:721-731.
    • (1991) Circulation , vol.84 , pp. 721-731
    • Rogers, W.J.1    Shapiro, E.P.2    Weiss, J.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.