메뉴 건너뛰기




Volumn 21, Issue 8, 1996, Pages 615-617

High-sensitivity intrinsic fiber-optic Fabry-Perot pressure sensor

Author keywords

[No Author keywords available]

Indexed keywords

CALCULATIONS; DIAPHRAGMS; DYNAMIC RESPONSE; ELASTIC MODULI; ELASTICITY; FABRY-PEROT INTERFEROMETERS; FREQUENCIES; MATHEMATICAL MODELS; PRESSURE EFFECTS; PRESSURE TRANSDUCERS; STAINLESS STEEL;

EID: 0030129197     PISSN: 01469592     EISSN: None     Source Type: Journal    
DOI: 10.1364/OL.21.000615     Document Type: Article
Times cited : (74)

References (6)
  • 1
    • 0000778429 scopus 로고
    • Sensors for smart structure based upon the Fabry-Perot interferometer
    • E. Udd, ed. Wiley, New York
    • C. E. Lee and H. F. Taylor, "Sensors for smart structure based upon the Fabry-Perot interferometer," in Fiber Optics Smart Structures, E. Udd, ed. (Wiley, New York, 1995), pp. 249-269.
    • (1995) Fiber Optics Smart Structures , pp. 249-269
    • Lee, C.E.1    Taylor, H.F.2
  • 4
    • 0000150644 scopus 로고
    • Intensity-based and Fabry-Perot interferometer sensors
    • E. Udd, ed. Wiley Interscience, New York
    • G. L. Mitchell, "Intensity-based and Fabry-Perot interferometer sensors," in Fiber Optics Sensors: An Introduction for Engineers and Scientists, E. Udd, ed. (Wiley Interscience, New York, 1991), p. 139.
    • (1991) Fiber Optics Sensors: An Introduction for Engineers and Scientists , pp. 139
    • Mitchell, G.L.1