메뉴 건너뛰기




Volumn 7, Issue 1, 1996, Pages 7-17

Field tests of correction procedures for turbine flowmeters in pulsatile flows

Author keywords

Pulsation profiles; Turbine meter correction procedures; Turbine meter over registration

Indexed keywords

ERROR ANALYSIS; ERROR CORRECTION; GAS PIPELINES; INSTRUMENT ERRORS; OSCILLATIONS; PULSATILE FLOW;

EID: 0030110783     PISSN: 09555986     EISSN: None     Source Type: Journal    
DOI: 10.1016/0955-5986(96)00004-0     Document Type: Article
Times cited : (17)

References (10)
  • 1
    • 84965912880 scopus 로고
    • The theory of the vane anemometer
    • Ower, E. The theory of the vane anemometer. Phil. Mag., Ser. 7 2 (1926) 881-900
    • (1926) Phil. Mag., Ser. 7 , vol.2 , pp. 881-900
    • Ower, E.1
  • 2
    • 0041372063 scopus 로고
    • Currentmeter errors under pulsating flow conditions
    • Jepson, P. Currentmeter errors under pulsating flow conditions. J. Mech. Engng Sci. 9(1) (1967) 45-54
    • (1967) J. Mech. Engng Sci. , vol.9 , Issue.1 , pp. 45-54
    • Jepson, P.1
  • 3
    • 0041872825 scopus 로고
    • Dynamic response of turbine flow meters
    • Dijstelbergen, H. H. Dynamic response of turbine flow meters. Instrument Review 13 (1966) 241-245
    • (1966) Instrument Review , vol.13 , pp. 241-245
    • Dijstelbergen, H.H.1
  • 4
    • 0042373820 scopus 로고
    • Measurement of noisy and pulsating flows in Industrial and Laboratory environments
    • Melbourne, Australia
    • Mottram, R. C. Measurement of noisy and pulsating flows in Industrial and Laboratory environments. Proc. IMEKO Conf. on Flow Measurement, Melbourne, Australia, 1985, pp. 213-221
    • (1985) Proc. IMEKO Conf. on Flow Measurement , pp. 213-221
    • Mottram, R.C.1
  • 6
    • 0042373817 scopus 로고
    • The dynamic behaviour of a turbine flowmeter
    • van Mill, C. H. The dynamic behaviour of a turbine flowmeter. Revue A 6 (1964) 169-173
    • (1964) Revue A , vol.6 , pp. 169-173
    • Van Mill, C.H.1
  • 7
    • 0026807087 scopus 로고
    • A software tool to calculate the over-registration error of a turbine meter in pulsating flow
    • Atkinson, K. N. A software tool to calculate the over-registration error of a turbine meter in pulsating flow. Flow Meas. Instrum. 3(3) (1992) 167-172
    • (1992) Flow Meas. Instrum. , vol.3 , Issue.3 , pp. 167-172
    • Atkinson, K.N.1
  • 8
    • 84920308071 scopus 로고
    • Monitoring pulsation errors in turbine meters. Poster presentation
    • Milan, Italy, June
    • Viljeer, J. and ter Horst, G. Monitoring pulsation errors in turbine meters. Poster presentation, 19th World Gas Conference, Milan, Italy, June 1994
    • (1994) 19th World Gas Conference
    • Viljeer, J.1    Ter Horst, G.2
  • 9
    • 0042874866 scopus 로고
    • Measurements with a turbine flow meter in the presence of large, non-sinusoidal pulsations
    • Toulouse, France August
    • Cheesewright, R., Edwards, D. and Clark, C. Measurements with a turbine flow meter in the presence of large, non-sinusoidal pulsations. Proc. FLUCOME '94, Toulouse, France August 1994
    • (1994) Proc. FLUCOME '94
    • Cheesewright, R.1    Edwards, D.2    Clark, C.3
  • 10
    • 0041872828 scopus 로고
    • The influence of forces due to electromagnetic pick-ups on the performance of small turbine flowmeters
    • Cheesewright, R. and Clark, C. The influence of forces due to electromagnetic pick-ups on the performance of small turbine flowmeters, submitted for publication in Proc. J. Mech. E. (1995)
    • (1995) Proc. J. Mech. E.
    • Cheesewright, R.1    Clark, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.