메뉴 건너뛰기




Volumn 32, Issue 2, 1996, Pages 459-470

The mechanisms of high gradient magnetic separation of human blood and bone marrow

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD; BONE; CELLS; DIAMAGNETISM; FERRIMAGNETIC MATERIALS; MAGNETIC MATERIALS; MAGNETIC PERMEABILITY; MAGNETIZATION; MECHANISMS; PARAMAGNETISM; WIRE;

EID: 0030106663     PISSN: 00189464     EISSN: None     Source Type: Journal    
DOI: 10.1109/20.486533     Document Type: Article
Times cited : (15)

References (52)
  • 1
    • 0027892623 scopus 로고
    • Positive selection of human blood cells using improved high gradient magnetic separation filters
    • T. E. Thomas et al., "Positive selection of human blood cells using improved high gradient magnetic separation filters," J. Hematotherapy, vol. 2, no. 3, pp. 297-303, 1993.
    • (1993) J. Hematotherapy , vol.2 , Issue.3 , pp. 297-303
    • Thomas, T.E.1
  • 4
    • 0028710162 scopus 로고
    • Specific capture of targeted haemopoietic cells by high gradient magnetic separation by the use of ordered wire array filters and tetrameric antibody complexes linked to a dextran iron particle
    • New York: Wiley-Liss
    • S. Roath et al., "Specific capture of targeted haemopoietic cells by high gradient magnetic separation by the use of ordered wire array filters and tetrameric antibody complexes linked to a dextran iron particle," in Advances in Bone Marrow Purging and Processing: Fourth International Symposium. New York: Wiley-Liss, 1994, pp. 155-163.
    • (1994) Advances in Bone Marrow Purging and Processing: Fourth International Symposium , pp. 155-163
    • Roath, S.1
  • 6
    • 0017537920 scopus 로고
    • Rapid evaluation of magnetic filter performance
    • Sept.
    • H. K. Collan, M. Kokkala, A. Ritvos, and V. and V. Pohjola, "Rapid evaluation of magnetic filter performance," IEEE Trans. Magn., vol. MAG-13, no. 5, pp. 1480-1482, Sept. 1977.
    • (1977) IEEE Trans. Magn. , vol.MAG-13 , Issue.5 , pp. 1480-1482
    • Collan, H.K.1    Kokkala, M.2    Ritvos, A.3    Pohjola, V.4
  • 7
    • 0018008475 scopus 로고
    • Experimental determination of the separation performance of various types of filter matrix
    • H. K. Collan, J. Jantunen, M. Kokkala, and A. Ritvos, "Experimental determination of the separation performance of various types of filter matrix," IEEE Trans. Magn., vol. MAG-14, no. 5, pp. 398-400, 1978.
    • (1978) IEEE Trans. Magn. , vol.MAG-14 , Issue.5 , pp. 398-400
    • Collan, H.K.1    Jantunen, J.2    Kokkala, M.3    Ritvos, A.4
  • 8
    • 0018544208 scopus 로고
    • Analysis of magnetic filter experiments with polydisperse particle suspensions
    • H. K. Collan, M. Kokkala, and A. Ritvos, "Analysis of magnetic filter experiments with polydisperse particle suspensions," IEEE Trans. Magn., vol. MAG-15, no. 6, pp. 529-1531, 1979.
    • (1979) IEEE Trans. Magn. , vol.MAG-15 , Issue.6 , pp. 529-1531
    • Collan, H.K.1    Kokkala, M.2    Ritvos, A.3
  • 9
    • 0018781336 scopus 로고
    • Inversion of the breakthrough curve of a high gradient magnetic filter: Theory and experiment
    • Y. A. Liu, Ed., IEEE Publ. 78CH1447-2 MAG
    • H. K. Collan, J. Jantunen, M. Kokkala, and A. Ritvos, "Inversion of the breakthrough curve of a high gradient magnetic filter: theory and experiment," in Industrial Applications of Magnetic Separation, Y. A. Liu, Ed., IEEE Publ. 78CH1447-2 MAG, pp. 175-187, 1979.
    • (1979) Industrial Applications of Magnetic Separation , pp. 175-187
    • Collan, H.K.1    Jantunen, J.2    Kokkala, M.3    Ritvos, A.4
  • 11
    • 0019559874 scopus 로고
    • Application of theory of magnetic filtration in determining the optimum filter configuration
    • May
    • H. K. Collan, M. A. Kokkala, and O. E. Toikka, "Application of theory of magnetic filtration in determining the optimum filter configuration," IEEE Trans. Magn., vol. MAG-18, no. 3, May 1982.
    • (1982) IEEE Trans. Magn. , vol.MAG-18 , Issue.3
    • Collan, H.K.1    Kokkala, M.A.2    Toikka, O.E.3
  • 12
    • 33747709802 scopus 로고
    • Magnetic filtration of steel mill effluent waters
    • Appl. Phys. Ser., Ph.
    • _, "Magnetic filtration of steel mill effluent waters," Acta Polytechnica Scandinavica, Appl. Phys. Ser., Ph. 133, 1982.
    • (1982) Acta Polytechnica Scandinavica , pp. 133
  • 13
    • 33747699464 scopus 로고
    • Rep. TKK-F-A467, Helsinki Univ. of Technology, Otaniemi, Finland
    • _, "Mathematical model for an axial magnetic filter," Rep. TKK-F-A467, Helsinki Univ. of Technology, Otaniemi, Finland, 1982.
    • (1982) Mathematical Model for An Axial Magnetic Filter
  • 14
    • 33747709801 scopus 로고
    • A new mathematical model for the performance of axial magnetic filters
    • _, "A new mathematical model for the performance of axial magnetic filters," Magn. Separation News, vol. 1, pp. 151-165, 1984.
    • (1984) Magn. Separation News , vol.1 , pp. 151-165
  • 15
    • 33747736997 scopus 로고
    • Breakthrough curves of magnetic filters: Theory, experiments, and application to filtration process design
    • F. J. Friedlaender and M. R. Parker, Eds. Cleveland: Chemical Rubber Company Press
    • M. A. Kokkala, "Breakthrough curves of magnetic filters: theory, experiments, and application to filtration process design," in Magnetic Separation with Special Emphasis on High Gradient Magnetic Separation, F. J. Friedlaender and M. R. Parker, Eds. Cleveland: Chemical Rubber Company Press, 1983.
    • (1983) Magnetic Separation with Special Emphasis on High Gradient Magnetic Separation
    • Kokkala, M.A.1
  • 18
    • 0015669742 scopus 로고
    • Magnetic filtration
    • Sept.
    • J. H. P. Watson, "Magnetic filtration," J. Appl. Phys., vol. 44, no. 9, Sept. 1973.
    • (1973) J. Appl. Phys. , vol.44 , Issue.9
    • Watson, J.H.P.1
  • 19
    • 0010573749 scopus 로고
    • Analysis of matrix systems in high intensity magnetic separation
    • July/Aug.
    • R. R. Birss, R. Gerber, and M. R. Parker, "Analysis of matrix systems in high intensity magnetic separation," Filtration & Separation, pp. 339-342, July/Aug. 1977.
    • (1977) Filtration & Separation , pp. 339-342
    • Birss, R.R.1    Gerber, R.2    Parker, M.R.3
  • 20
    • 0024734315 scopus 로고
    • The HGMS filter performance exponential law
    • Sept.
    • R. Gerber and P. Lawson, "The HGMS filter performance exponential law," IEEE Trans. Magn., vol. 25, no. 5, Sept. 1989.
    • (1989) IEEE Trans. Magn. , vol.25 , Issue.5
    • Gerber, R.1    Lawson, P.2
  • 21
    • 0024733147 scopus 로고
    • Particle capture in the matrix of a magnetic separator
    • J. Svoboda and V. E. Ross, "Particle capture in the matrix of a magnetic separator," Int. J. Mineral Processing, vol. 27, pp. 75-94, 1989.
    • (1989) Int. J. Mineral Processing , vol.27 , pp. 75-94
    • Svoboda, J.1    Ross, V.E.2
  • 22
    • 0006869904 scopus 로고
    • Capture mechanisms in filtration
    • K. J. Ives, Ed. Noordhoff-Leyden
    • K. J. Ives, "Capture mechanisms in filtration," The Scientific Basis of Filtration, K. J. Ives, Ed. Noordhoff-Leyden, 1975, pp. 183-202.
    • (1975) The Scientific Basis of Filtration , pp. 183-202
    • Ives, K.J.1
  • 23
    • 0001111405 scopus 로고
    • Interceptional and gravitational collision efficiencies for single collectors at intermediate Reynolds numbers
    • M. E. Weber and D. Paddock, Ed. Aug.
    • M. E. Weber and D. Paddock, Ed. "Interceptional and gravitational collision efficiencies for single collectors at intermediate Reynolds numbers," J. Colloid and Interface Sci., vol. 94, no. 2, Aug. 1983.
    • (1983) J. Colloid and Interface Sci. , vol.94 , Issue.2
  • 30
    • 3042881918 scopus 로고
    • High gradient magnetic separation
    • chapter 22 L. Svarovsky, Ed., third ed. Butterworths
    • J. H. P. Watson, "High gradient magnetic separation," chapter 22 in Solid-Liquid Separation, L. Svarovsky, Ed., third ed. Butterworths, 1990.
    • (1990) Solid-Liquid Separation
    • Watson, J.H.P.1
  • 31
    • 0016952301 scopus 로고
    • Traction force on paramagnetic particles in magnetic separators
    • May
    • A. Aharoni, "Traction force on paramagnetic particles in magnetic separators," IEEE Trans. Magn., vol. MAG-12, no. 3, pp. 234-235, May 1976.
    • (1976) IEEE Trans. Magn. , vol.MAG-12 , Issue.3 , pp. 234-235
    • Aharoni, A.1
  • 32
    • 33747746756 scopus 로고
    • "Magnetic filter with ordered wire array and method for using same," United States Patent Application Serial No. 08/121,098
    • P. M. Lansdorp and A. J. Richards, "Magnetic filter with ordered wire array and method for using same," United States Patent Application Serial No. 08/121,098, 1993.
    • (1993)
    • Lansdorp, P.M.1    Richards, A.J.2
  • 35
    • 0017018463 scopus 로고
    • Theory and design of axially ordered filters for high intensity magnetic separation
    • Nov.
    • R. R. Birss, R. Gerber, and M. R. Parker, "Theory and design of axially ordered filters for high intensity magnetic separation," IEEE Trans. Magn., vol. MAG-12, no. 6, pp. 892-894, Nov. 1976.
    • (1976) IEEE Trans. Magn. , vol.MAG-12 , Issue.6 , pp. 892-894
    • Birss, R.R.1    Gerber, R.2    Parker, M.R.3
  • 36
    • 0018925890 scopus 로고
    • A radioactive tracer technique for evaluation of magnetic filter performance
    • Sept.
    • R. R. Birss, M. R. Parker, and T. J. Sheerer, "A radioactive tracer technique for evaluation of magnetic filter performance," IEEE Trans. Magn., vol. MAG-16, no. 5, pp. 836-839, Sept. 1980.
    • (1980) IEEE Trans. Magn. , vol.MAG-16 , Issue.5 , pp. 836-839
    • Birss, R.R.1    Parker, M.R.2    Sheerer, T.J.3
  • 37
    • 0019065531 scopus 로고
    • Statistics of particle capture in HGMS
    • Sept.
    • _, "Statistics of particle capture in HGMS," IEEE Trans. Magn., vol. MAG-16, no. 5, pp. 830-832. Sept. 1980.
    • (1980) IEEE Trans. Magn. , vol.MAG-16 , Issue.5 , pp. 830-832
  • 38
    • 0018994346 scopus 로고
    • Efficiency comparison of two preparative mechanisms for magnetic separation of erythrocytes from whole blood
    • Mar.
    • M. D. Graham, "Efficiency comparison of two preparative mechanisms for magnetic separation of erythrocytes from whole blood," J. Appl. Phys., vol. 52, no. 3, p. 2578, Mar. 1981.
    • (1981) J. Appl. Phys. , vol.52 , Issue.3 , pp. 2578
    • Graham, M.D.1
  • 39
    • 0021485165 scopus 로고
    • The (comparative) performance of HGMS filters with a strictly ordered wire matrix in the axial and transverse configuration
    • Sept.
    • H. Greiner, G. Reger, and H. Hoffmann, "The (comparative) performance of HGMS filters with a strictly ordered wire matrix in the axial and transverse configuration," IEEE Trans. Magn., vol. MAG-20, no. 5, pp. 1171-1173, Sept. 1984.
    • (1984) IEEE Trans. Magn. , vol.MAG-20 , Issue.5 , pp. 1171-1173
    • Greiner, H.1    Reger, G.2    Hoffmann, H.3
  • 40
    • 0026939663 scopus 로고
    • Theoretical and single-wire studies of vortex magnetic separation
    • J. H. P. Watson and Z. Li, "Theoretical and single-wire studies of vortex magnetic separation," Minerals Eng., vol. 5, nos. 10-12, pp. 1147-1165, 1992.
    • (1992) Minerals Eng. , vol.5 , Issue.10-12 , pp. 1147-1165
    • Watson, J.H.P.1    Li, Z.2
  • 41
    • 0025067888 scopus 로고
    • Positive stem cell selection - Basic science
    • Alan R. Liss
    • C. I. Civin et al., "Positive stem cell selection - basic science," in Bone Marrow Purging and Processing. Alan R. Liss, 1990, pp. 387-402.
    • (1990) Bone Marrow Purging and Processing , pp. 387-402
    • Civin, C.I.1
  • 42
    • 0025745981 scopus 로고
    • A study on mechanical entrapment in HGMS and vibration HGMS
    • J. H. P. Watson and Z. Li, "A study on mechanical entrapment in HGMS and vibration HGMS," Minerals Eng., vol. 4, nos. 7-11, pp. 815-823, 1991.
    • (1991) Minerals Eng. , vol.4 , Issue.7-11 , pp. 815-823
    • Watson, J.H.P.1    Li, Z.2
  • 43
    • 33747639632 scopus 로고
    • A study of vibration high gradient magnetic separation
    • Cannes, June
    • Z. Sun and Z. Li, "A study of vibration high gradient magnetic separation," in Proc. XVth Int. Mineral Processing Congress, Cannes, June 1985, pp. 410-421.
    • (1985) Proc. XVth Int. Mineral Processing Congress , pp. 410-421
    • Sun, Z.1    Li, Z.2
  • 44
    • 0023346062 scopus 로고
    • Magnetic separation in alternating fields
    • May
    • O. Goodluck, J. Finch, and M. Leroux, "Magnetic separation in alternating fields," IEEE Trans. Magn., vol. MAG-23, no. 3, May 1987.
    • (1987) IEEE Trans. Magn. , vol.MAG-23 , Issue.3
    • Goodluck, O.1    Finch, J.2    Leroux, M.3
  • 45
    • 0024112214 scopus 로고
    • Single wire particle collection with magnetic field components along the wire axis
    • Nov.
    • J. Svoboda, F. J. Friedlaender, Fu Hua, and S. W. Luan, "Single wire particle collection with magnetic field components along the wire axis," IEEE Trans. Magn., vol. 24, no. 6, pp. 2419-2421, Nov. 1988.
    • (1988) IEEE Trans. Magn. , vol.24 , Issue.6 , pp. 2419-2421
    • Svoboda, J.1    Friedlaender, F.J.2    Hua, F.3    Luan, S.W.4
  • 46
    • 0019793877 scopus 로고
    • High gradient magnetic separation of rosette forming cells
    • C. S. Owens and E. Moore, "High gradient magnetic separation of rosette forming cells," Cell Biophys., vol. 3, pp. 141-153, 1981.
    • (1981) Cell Biophys. , vol.3 , pp. 141-153
    • Owens, C.S.1    Moore, E.2
  • 47
    • 0020128703 scopus 로고
    • High gradient magnetic capture of red blood cells
    • _, "High gradient magnetic capture of red blood cells," J. Appl. Phys., vol. 53, p. 3884, 1982.
    • (1982) J. Appl. Phys. , vol.53 , pp. 3884
  • 49
    • 0024334831 scopus 로고
    • Specific binding and release of cells from beads using cleavable tetrameric antibody complexes
    • T. E. Thomas, H. J. Sutherland, and P. M. Lansdorp, "Specific binding and release of cells from beads using cleavable tetrameric antibody complexes," J. Immunological Methods, vol. 120, pp. 221-231, 1989.
    • (1989) J. Immunological Methods , vol.120 , pp. 221-231
    • Thomas, T.E.1    Sutherland, H.J.2    Lansdorp, P.M.3
  • 50
    • 0018781328 scopus 로고
    • Analytical theory of magnetic particle capture process and capture radius in high gradient magnetic separation
    • Y. A. Liu, Ed., IEEE Catalog No. 78CHII447-2
    • S. Uchiyama and K. Hayashi, "Analytical theory of magnetic particle capture process and capture radius in high gradient magnetic separation," in Industrial Applications of Magnetic Separation, Y. A. Liu, Ed., IEEE Catalog No. 78CHII447-2, 1979, pp. 169-173.
    • (1979) Industrial Applications of Magnetic Separation , pp. 169-173
    • Uchiyama, S.1    Hayashi, K.2
  • 51
    • 0020814118 scopus 로고
    • The magnetic field and force in a perpendicularly magnetised matrix consisting of parallel ordered ferromagnetic wires,''
    • H. Greiner and H. Hoffmann, "The magnetic field and force in a perpendicularly magnetised matrix consisting of parallel ordered ferromagnetic wires,'' J. Magn. Magn. Mat., vol. 38, pp. 187-193, 1983.
    • (1983) J. Magn. Magn. Mat. , vol.38 , pp. 187-193
    • Greiner, H.1    Hoffmann, H.2
  • 52
    • 84945721338 scopus 로고
    • Particle retention in high-intensity magnetic separation
    • Symp. at Loughborough Univ., England, Sept. 6-8
    • J. H. P. Watson, "Particle retention in high-intensity magnetic separation," in Deposition and Filtration of Particles from Gases & Liquids, pp. 43-60, Symp. at Loughborough Univ., England, Sept. 6-8, 1978.
    • (1978) Deposition and Filtration of Particles from Gases & Liquids , pp. 43-60
    • Watson, J.H.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.