메뉴 건너뛰기




Volumn 34, Issue 2, 1996, Pages 231-240

The in situ permeable flow sensor a ground-water flow velocity meter

Author keywords

[No Author keywords available]

Indexed keywords

DATA ACQUISITION; DATABASE SYSTEMS; GROUNDWATER FLOW; PERTURBATION TECHNIQUES; TECHNOLOGY; THERMODYNAMIC PROPERTIES; VELOCIMETERS; VELOCITY MEASUREMENT;

EID: 0030106580     PISSN: 0017467X     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1745-6584.1996.tb01883.x     Document Type: Article
Times cited : (52)

References (14)
  • 1
    • 3743130546 scopus 로고
    • An in situ permeable flow sensor to monitor groundwater flow
    • Ballard, S. 1992a. An in situ permeable flow sensor to monitor groundwater flow. Sensors Magazine. v. 9, no. 13, pp. 20-26.
    • (1992) Sensors Magazine , vol.9 , Issue.13 , pp. 20-26
    • Ballard, S.1
  • 5
    • 85033826727 scopus 로고    scopus 로고
    • A test of the in Situ Permeable Flow Sensor at Savannah River, SC
    • In press
    • Ballard, S., G. T. Barker, and R. L. Nichols. In press. A test of the In Situ Permeable Flow Sensor at Savannah River, SC. Ground Water.
    • Ground Water
    • Ballard, S.1    Barker, G.T.2    Nichols, R.L.3
  • 6
    • 0021427707 scopus 로고
    • Fitting curves to data
    • Caceci, M. S. and W. P. Cacheris. 1984. Fitting curves to data. Byte. v. 9, no. 5, pp. 340-362.
    • (1984) Byte , vol.9 , Issue.5 , pp. 340-362
    • Caceci, M.S.1    Cacheris, W.P.2
  • 9
    • 85167348949 scopus 로고
    • Monitoring well construction and recommended procedures for direct ground-water flow measurements using a heat-pulsing flowmeter
    • A. G. Collins and A. I. Johnson, eds., American Society for Testing and Materials, Philadelphia. ASTM STP 963
    • Kerfoot, W. B. 1988. Monitoring well construction and recommended procedures for direct ground-water flow measurements using a heat-pulsing flowmeter. Ground-Water Contamination: Field Methods. A. G. Collins and A. I. Johnson, eds., American Society for Testing and Materials, Philadelphia. ASTM STP 963. pp. 146-161.
    • (1988) Ground-Water Contamination: Field Methods , pp. 146-161
    • Kerfoot, W.B.1
  • 10
    • 0022264431 scopus 로고
    • Monitoring well screen influence on direct flowmeter measurement
    • Kerfoot, W. B. and V. A. Massard. 1985. Monitoring well screen influence on direct flowmeter measurement. Ground Water Monitoring Review. v. 5, no. 4, pp. 74-77.
    • (1985) Ground Water Monitoring Review , vol.5 , Issue.4 , pp. 74-77
    • Kerfoot, W.B.1    Massard, V.A.2
  • 11
    • 0022266256 scopus 로고
    • Laboratory investigation and analysis of a ground-water flowmeter
    • Melville, J. G., F. J. Molz, and O. Güven. 1985. Laboratory investigation and analysis of a ground-water flowmeter. Ground Water. v. 23, no. 4, pp. 486-495.
    • (1985) Ground Water , vol.23 , Issue.4 , pp. 486-495
    • Melville, J.G.1    Molz, F.J.2    Güven, O.3
  • 13
    • 0043118245 scopus 로고
    • Forced convection past a slender body in a saturated porous medium
    • Romero, L. A. 1995. Forced convection past a slender body in a saturated porous medium. Jour. Applied Math. v. 55, no. 4.
    • (1995) Jour. Applied Math , vol.55 , Issue.4
    • Romero, L.A.1
  • 14
    • 0022361798 scopus 로고
    • Steady state flow passing through a cylinder of permeability different from the surrounding medium
    • Wheatcraft, S. W. and F. Winterberg. 1985. Steady state flow passing through a cylinder of permeability different from the surrounding medium. Water Resources Research. v. 21, no. 12, pp. 1923-1929.
    • (1985) Water Resources Research , vol.21 , Issue.12 , pp. 1923-1929
    • Wheatcraft, S.W.1    Winterberg, F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.