메뉴 건너뛰기




Volumn 48, Issue 2, 1996, Pages 119-123

New closure devices for left-to-right shunt

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; ARTIFICIAL EMBOLISM; CHILD; HEART CATHETERIZATION; HEART SEPTUM DEFECT; HEART SURGERY; HUMAN; INFANT; INSTRUMENTATION; NEWBORN; PATENT DUCTUS ARTERIOSUS; PRESCHOOL CHILD; REVIEW;

EID: 0030101501     PISSN: 00194832     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (3)

References (22)
  • 1
    • 0002827014 scopus 로고
    • The incidence of congenital heart disease in children born in Gothenburg 1941-1950
    • Carlgren LE. The incidence of congenital heart disease in children born in Gothenburg 1941-1950. Br Heart J 1959; 21: 40-50
    • (1959) Br Heart J , vol.21 , pp. 40-50
    • Carlgren, L.E.1
  • 2
    • 0014235755 scopus 로고
    • Natural history of persistent ductus arteriosus
    • Campbell M. Natural history of persistent ductus arteriosus. Br Heart J 1968; 30: 4-13
    • (1968) Br Heart J , vol.30 , pp. 4-13
    • Campbell, M.1
  • 3
    • 84942386507 scopus 로고
    • Surgical ligation of a patent ductus arteriosus: Report of first successful case
    • Gross RE, Hubbard JP. Surgical ligation of a patent ductus arteriosus: report of first successful case. J Am Med Asoc 1939; 112: 729-731
    • (1939) J Am Med Asoc , vol.112 , pp. 729-731
    • Gross, R.E.1    Hubbard, J.P.2
  • 4
    • 0028051590 scopus 로고
    • Forty-six years of patent ductus arteriosus division at Children's Memorial Hospital of Chicago. Standards for comparison
    • Mavroudis C, Backer CL, Gevitz M. Forty-six years of patent ductus arteriosus division at Children's Memorial Hospital of Chicago. Standards for comparison. Ann Surg 1994; 220: 402-410
    • (1994) Ann Surg , vol.220 , pp. 402-410
    • Mavroudis, C.1    Backer, C.L.2    Gevitz, M.3
  • 5
    • 0024841969 scopus 로고
    • Two dimensional echocardigraphic and color flow Doppler evaluation of ductal occlusion with the Rashkind Prosthesis
    • Musewe NN, Bensen LN, Smallhorn JF, Freedom RM: Two dimensional echocardigraphic and color flow Doppler evaluation of ductal occlusion with the Rashkind Prosthesis. Circulation 1989; 80: 1706-1710
    • (1989) Circulation , vol.80 , pp. 1706-1710
    • Musewe, N.N.1    Bensen, L.N.2    Smallhorn, J.F.3    Freedom, R.M.4
  • 7
    • 0026016877 scopus 로고
    • Frequency of occurrence of residual ductal flow after surgical ligation by color flow mapping
    • Sorensen KE, Kristensen BO, Hansen OK. Frequency of occurrence of residual ductal flow after surgical ligation by color flow mapping. Am J Cardiol 1991; 67: 653-654
    • (1991) Am J Cardiol , vol.67 , pp. 653-654
    • Sorensen, K.E.1    Kristensen, B.O.2    Hansen, O.K.3
  • 8
    • 0014096990 scopus 로고
    • Closure of the persistent ductus arteriosus without thoracotomy
    • Porstmann W, Wierny L, Warneke H. Closure of the persistent ductus arteriosus without thoracotomy. Ger Med Mon 1967; 12: 259-261
    • (1967) Ger Med Mon , vol.12 , pp. 259-261
    • Porstmann, W.1    Wierny, L.2    Warneke, H.3
  • 9
    • 0018573483 scopus 로고
    • Transcatheter closure of a patent ductus arteriosus: Successful use in a 3.5 kg infant
    • Rashkind WJ, Cuaso CC. Transcatheter closure of a patent ductus arteriosus: successful use in a 3.5 kg infant. Pediatr Cardiol 1979; 1: 3-7
    • (1979) Pediatr Cardiol , vol.1 , pp. 3-7
    • Rashkind, W.J.1    Cuaso, C.C.2
  • 10
    • 0023153198 scopus 로고
    • Nonsurgical closure of patent ductsu arteriosus: Clinical application of the Rashkind PDA occluder system
    • Rashkind WJ, Mullins CE, Hellenbrand WE, et al. Nonsurgical closure of patent ductsu arteriosus: Clinical application of the Rashkind PDA occluder system. Circulation 1987; 75: 583-592
    • (1987) Circulation , vol.75 , pp. 583-592
    • Rashkind, W.J.1    Mullins, C.E.2    Hellenbrand, W.E.3
  • 11
    • 0026754817 scopus 로고
    • Front loading of double umbrella devices: A new technique for umbrella delivery for closing cardiovascular defects
    • Perry SB, Lock JE. Front loading of double umbrella devices: a new technique for umbrella delivery for closing cardiovascular defects. Am J Cardiol 1992; 70: 917-920
    • (1992) Am J Cardiol , vol.70 , pp. 917-920
    • Perry, S.B.1    Lock, J.E.2
  • 12
    • 0027301293 scopus 로고
    • Transcatheter occlusion of patent ductus arteriosus with adjustable buttoned device. Initial clinical experience
    • Rao PS, Sideris EB, Haddad J, Rey C, Hausdorf G, Wilson AD, et al. Transcatheter occlusion of patent ductus arteriosus with adjustable buttoned device. Initial clinical experience. Circulation 1993; 88: 1119-1126
    • (1993) Circulation , vol.88 , pp. 1119-1126
    • Rao, P.S.1    Sideris, E.B.2    Haddad, J.3    Rey, C.4    Hausdorf, G.5    Wilson, A.D.6
  • 13
    • 0027423486 scopus 로고
    • Results of transcatheter closure of the patent ductus arteriosus with the Botalloocluder
    • Verin VE, Saveliev VS, Kolody SM, Prokubovski VI. Results of transcatheter closure of the patent ductus arteriosus with the Botalloocluder. J Am Coll Cardiol 1993; 22: 1509-1514
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1509-1514
    • Verin, V.E.1    Saveliev, V.S.2    Kolody, S.M.3    Prokubovski, V.I.4
  • 16
    • 0028092055 scopus 로고
    • Results of anterograde transcatheter closure of patent ductus arteriosus using single or multiple Gianturco coils
    • Hijazi ZM, Geggel RL. Results of anterograde transcatheter closure of patent ductus arteriosus using single or multiple Gianturco coils Am J Cardiol 1994; 74: 925-929
    • (1994) Am J Cardiol , vol.74 , pp. 925-929
    • Hijazi, Z.M.1    Geggel, R.L.2
  • 17
    • 0017300623 scopus 로고
    • Secundum atrial septal defect. Nonoperative closure during cardiac catheterization
    • King TD, Thompson SL, Steiner C, Mills NL. Secundum atrial septal defect. Nonoperative closure during cardiac catheterization. JAMA 1976; 235: 2506-2509
    • (1976) JAMA , vol.235 , pp. 2506-2509
    • King, T.D.1    Thompson, S.L.2    Steiner, C.3    Mills, N.L.4
  • 18
    • 0001431777 scopus 로고
    • The clinical impact of catheter closure of secundum atrial septal defects with the double umbrella device. Up to 56 months follow-up
    • Justo RN, Nykanen DG, McCrindle BW, Boutin C, Benson LN. The clinical impact of catheter closure of secundum atrial septal defects with the double umbrella device. Up to 56 months follow-up. Circulation 1995 (Suppl 1); 92: 1-308
    • (1995) Circulation , vol.92 , Issue.1 SUPPL. , pp. 1-308
    • Justo, R.N.1    Nykanen, D.G.2    McCrindle, B.W.3    Boutin, C.4    Benson, L.N.5
  • 19
    • 0028139119 scopus 로고
    • International experience with secundum atrial septal defect occlusion by the buttoned device
    • Rao PS, Sideris EB, Hausdorf G, Rey C, Lloyd TR, Beekman RH, et al. International experience with secundum atrial septal defect occlusion by the buttoned device. Am Heart J 1994; 128: 1022-1035
    • (1994) Am Heart J , vol.128 , pp. 1022-1035
    • Rao, P.S.1    Sideris, E.B.2    Hausdorf, G.3    Rey, C.4    Lloyd, T.R.5    Beekman, R.H.6
  • 20
    • 0027515761 scopus 로고
    • Experimental atrial septal defect closure with a new transcatheter, self-centering device
    • Das GS, Voss G, Jarvis G, Wyche K, Gunther R, Wilson RF. Experimental atrial septal defect closure with a new transcatheter, self-centering device. Circulation 1993; 88 [part 1]. 1754-1764
    • (1993) Circulation , vol.88 , Issue.1 PART , pp. 1754-1764
    • Das, G.S.1    Voss, G.2    Jarvis, G.3    Wyche, K.4    Gunther, R.5    Wilson, R.F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.