메뉴 건너뛰기




Volumn 21, Issue 1, 1996, Pages 27-30

Clinical implications of collimator exchange effect, relative collimator and phantom scatter

Author keywords

Collimator exchange effect; Head scatter; Monitor unit; Phantom scatter

Indexed keywords

ARTICLE; HUMAN; INSTRUMENTATION; MEGAVOLTAGE RADIOTHERAPY; RADIATION DOSE; RADIATION SCATTERING; RADIOMETRY; STANDARD;

EID: 0030096006     PISSN: 09583947     EISSN: None     Source Type: Journal    
DOI: 10.1016/0958-3947(95)02058-6     Document Type: Article
Times cited : (5)

References (8)
  • 1
    • 0014835880 scopus 로고
    • The extension of the concept of tissue-air-ratios (TAR) to high energy x-ray beams
    • Holt, J.G.; Laughlin, J.S.; Morony, J.P. The extension of the concept of tissue-air-ratios (TAR) to high energy x-ray beams. Radiology 96:437-446; 1970.
    • (1970) Radiology , vol.96 , pp. 437-446
    • Holt, J.G.1    Laughlin, J.S.2    Morony, J.P.3
  • 3
    • 0027992838 scopus 로고
    • Head-scatter factors in blocked photon fields
    • Tatcher, M.; Bjärngard, B.E. Head-scatter factors in blocked photon fields. Radiother. Oncol. 33:64-67; 1994.
    • (1994) Radiother. Oncol. , vol.33 , pp. 64-67
    • Tatcher, M.1    Bjärngard, B.E.2
  • 5
    • 0042565365 scopus 로고
    • The determination of phantom and collimator scatter components of the output of megavoltage photon beams: Measurement of the collimator scatter part with a beam-coaxial narrow cylindrical phantom
    • van Gasteren, J.J.M.; Heukelom, S.; van Kleffens, H.J.; van der Laarse, R.; Venselaar, J.L.M.; Westermann, C.F. The determination of phantom and collimator scatter components of the output of megavoltage photon beams: measurement of the collimator scatter part with a beam-coaxial narrow cylindrical phantom. Radiother. Oncol. 24:55-59; 1992.
    • (1992) Radiother. Oncol. , vol.24 , pp. 55-59
    • Van Gasteren, J.J.M.1    Heukelom, S.2    Van Kleffens, H.J.3    Van Der Laarse, R.4    Venselaar, J.L.M.5    Westermann, C.F.6
  • 6
    • 0028082240 scopus 로고
    • The head-scatter factor for small field sizes
    • Zhu, T.C.; Bjärngard, B.E. The head-scatter factor for small field sizes. Med. Phys. 21 (1):65-68; 1994.
    • (1994) Med. Phys. , vol.21 , Issue.1 , pp. 65-68
    • Zhu, T.C.1    Bjärngard, B.E.2
  • 7
    • 85029976648 scopus 로고
    • Calculation of beam-data tables from a limited number of measurements
    • Vadash, P.; Bjärngard, B.E. Calculation of beam-data tables from a limited number of measurements. Med. Phys. 20(3):884; 1993.
    • (1993) Med. Phys. , vol.20 , Issue.3 , pp. 884
    • Vadash, P.1    Bjärngard, B.E.2
  • 8
    • 0024226572 scopus 로고
    • Effect of collimator setting on the output of rectangular fields from linear accelerators
    • Jani, S.K.; Pennington, E.C.; Wacha, J.E.; Anderson, K.M. Effect of collimator setting on the output of rectangular fields from linear accelerators. Med. Dos. 13:73-75; 1988.
    • (1988) Med. Dos. , vol.13 , pp. 73-75
    • Jani, S.K.1    Pennington, E.C.2    Wacha, J.E.3    Anderson, K.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.