메뉴 건너뛰기




Volumn 31, Issue 2, 1996, Pages 119-128

Measurements of Air Flow Characteristics in a Full-Scale Clean Room

Author keywords

[No Author keywords available]

Indexed keywords

AIR FLOW; CLEAN; ROOMS; TURBULENCE;

EID: 0030088251     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/0360-1323(95)00039-9     Document Type: Article
Times cited : (35)

References (15)
  • 3
    • 0008715161 scopus 로고
    • Numerical and experimental study on turbulent diffusion fields in conventional-flow-type clean rooms
    • S. Murakami, S. Sato and Y. Suyama, Numerical and experimental study on turbulent diffusion fields in conventional-flow-type clean rooms. ASHRAE Transactions 94(2), 469-493 (1988).
    • (1988) ASHRAE Transactions , vol.94 , Issue.2 , pp. 469-493
    • Murakami, S.1    Sato, S.2    Suyama, Y.3
  • 4
    • 0025531536 scopus 로고
    • Numerical study of flow and contaminant diffusion field as affected by flow obstacles in conventional-flow-type clean room
    • S. Murakami, S. Sato and Y. Suyama, Numerical study of flow and contaminant diffusion field as affected by flow obstacles in conventional-flow-type clean room. ASHRAE Transactions 96(2), 343-355 (1990).
    • (1990) ASHRAE Transactions , vol.96 , Issue.2 , pp. 343-355
    • Murakami, S.1    Sato, S.2    Suyama, Y.3
  • 5
    • 0024069971 scopus 로고
    • Computer simulation of air flow and particle transport in clean rooms
    • T. H. Kuehn, Computer simulation of air flow and particle transport in clean rooms. Journal of Environment Sciences XXXI, (September/October) 21-27 (1988).
    • (1988) Journal of Environment Sciences , vol.31 , Issue.SEPTEMBER-OCTOBER , pp. 21-27
    • Kuehn, T.H.1
  • 8
    • 0027841266 scopus 로고
    • The use of a three dimensional ultrasonic anemometer to measure the performance of clean zone air delivery systems
    • Las Vegas, NV, 2-7 May
    • D. Hope and D. Milholland, The use of a three dimensional ultrasonic anemometer to measure the performance of clean zone air delivery systems, in Proceedings of Institute of Environmental Sciences, 39th Annual Technical Meeting, pp. 516-528, Las Vegas, NV, 2-7 May (1993).
    • (1993) Proceedings of Institute of Environmental Sciences, 39th Annual Technical Meeting , pp. 516-528
    • Hope, D.1    Milholland, D.2
  • 9
    • 0042625228 scopus 로고
    • Near floor air speeds from center slot air inlets in swine barns
    • St. Joseph, MI
    • Y. Jin and J. Ogilivie, Near floor air speeds from center slot air inlets in swine barns. ASAE Paper No. 90-4004, St. Joseph, MI (1990).
    • (1990) ASAE Paper No. 90-4004
    • Jin, Y.1    Ogilivie, J.2
  • 10
    • 0019615136 scopus 로고
    • A review of research on subsonic turbulent flow reattachment
    • J. K. Eaton and J. P. Johnston, A review of research on subsonic turbulent flow reattachment. AIAA Journal 19, 1093-1100 (1981).
    • (1981) AIAA Journal , vol.19 , pp. 1093-1100
    • Eaton, J.K.1    Johnston, J.P.2
  • 12
    • 0004106166 scopus 로고
    • Institute of Environmental Science (IES), Mount Prospect, IL 60056
    • IES-RP-CC-006-84T, Recommended practice for testing clean rooms. Institute of Environmental Science (IES), Mount Prospect, IL 60056 (1984).
    • (1984) Recommended Practice for Testing Clean Rooms


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.