메뉴 건너뛰기




Volumn 11, Issue 1-2, 1996, Pages 119-126

The detection of lactate using the repeated application of stepped potentials to a micro-planar gold electrode

Author keywords

Amperometric lactate sensor; Ascorbic acid; Lactate oxidase; Planar gold electrode

Indexed keywords

AMPEROMETRIC SENSORS; BIOELECTRIC POTENTIALS; BIOLOGICAL MEMBRANES; CALIBRATION; COMPOSITION EFFECTS; ESTERS; HYDROGEN PEROXIDE; MICROELECTRODES;

EID: 0030070741     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/0956-5663(96)83719-5     Document Type: Article
Times cited : (9)

References (11)
  • 2
    • 0001175884 scopus 로고
    • Electropolymerised o-phenylenediamine film as a means of immobilising lactate oxidase for a L-lactate biosensor
    • Dempsey, E., Wang, J. & Smyth, M.R. (1993). Electropolymerised o-phenylenediamine film as a means of immobilising lactate oxidase for a L-lactate biosensor. Talanta, 40, 445-451.
    • (1993) Talanta , vol.40 , pp. 445-451
    • Dempsey, E.1    Wang, J.2    Smyth, M.R.3
  • 4
    • 0027248345 scopus 로고
    • Miniature electrochemical glucose biosensors
    • Koudelka, M.H., Strike, D.J. & Rooij, N.F. (1993). Miniature electrochemical glucose biosensors. Anal. Chim. Acta, 281, 461-466.
    • (1993) Anal. Chim. Acta , vol.281 , pp. 461-466
    • Koudelka, M.H.1    Strike, D.J.2    Rooij, N.F.3
  • 5
    • 0027917217 scopus 로고
    • Miniaturized flexible amperometric lactate probe
    • LiWang, D. & Heller, A. (1993). Miniaturized flexible amperometric lactate probe. Anal. Chem., 65, 1069-1073.
    • (1993) Anal. Chem. , vol.65 , pp. 1069-1073
    • LiWang, D.1    Heller, A.2
  • 6
    • 0001034903 scopus 로고
    • Strategies for reducing ascorbate interference at glucose oxidase-modified conducting organic salt electrodes
    • Lowry, J.P. & O'Neill, R.D. (1992). Strategies for reducing ascorbate interference at glucose oxidase-modified conducting organic salt electrodes. J. Electroanal. Chem., 334, 183-194.
    • (1992) J. Electroanal. Chem. , vol.334 , pp. 183-194
    • Lowry, J.P.1    O'Neill, R.D.2
  • 7
    • 33947148639 scopus 로고
    • Voltammetric and amperometric behaviour of uric acid at bare and surface-modified screen-printed electrodes: Studies towards a disposable uric acid sensor
    • Markas, A. T. G., Jhon, P. H. & Brain, B. (1992). Voltammetric and amperometric behaviour of uric acid at bare and surface-modified screen-printed electrodes: studies towards a disposable uric acid sensor. Analyst, 117, 1299-1303.
    • (1992) Analyst , vol.117 , pp. 1299-1303
    • Markas, A.T.G.1    Jhon, P.H.2    Brain, B.3
  • 9
    • 0022847117 scopus 로고
    • A micro-planar amperometric glucose sensor using an ISFET as a reference electrode
    • Murakami, T., Kimura, J., Kuriyama, T. & Karube, I. (1986), A micro-planar amperometric glucose sensor using an ISFET as a reference electrode. Anal. Lett., 19, 1973-1986.
    • (1986) Anal. Lett. , vol.19 , pp. 1973-1986
    • Murakami, T.1    Kimura, J.2    Kuriyama, T.3    Karube, I.4
  • 10
    • 0022664625 scopus 로고
    • A lift-off method for pattering enzyme-immobilized membranes in multi-biosensors
    • Nakamoto, S., Ito, N., Kuriyama, T. & Kimura, J. (1988). A lift-off method for pattering enzyme-immobilized membranes in multi-biosensors. Sensors and Actuators, 13, 165-172.
    • (1988) Sensors and Actuators , vol.13 , pp. 165-172
    • Nakamoto, S.1    Ito, N.2    Kuriyama, T.3    Kimura, J.4
  • 11
    • 0027496864 scopus 로고
    • Ascorbic acid interference in hydrogen peroxide detecting biosensors based on electrochemically immobilized enzymes
    • Palmisano, F. & Zambonin, P.G. (1993). Ascorbic acid interference in hydrogen peroxide detecting biosensors based on electrochemically immobilized enzymes. Anal. Chem., 65, 2690-2692.
    • (1993) Anal. Chem. , vol.65 , pp. 2690-2692
    • Palmisano, F.1    Zambonin, P.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.