메뉴 건너뛰기




Volumn 7, Issue 1, 1996, Pages 50-

Amperometric biosensors

Author keywords

[No Author keywords available]

Indexed keywords

AVIDIN; BIOTIN; DNA; GLUCOSE; HYDROGEN PEROXIDE;

EID: 0030066857     PISSN: 09581669     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (48)

References (39)
  • 1
    • 0027859050 scopus 로고
    • A fully active monolayer enzyme electrode derivatized by antigen-antibody attachment
    • Bourdillon C, Demaille C, Gueris J, Moiroux J, Saveant JM: A fully active monolayer enzyme electrode derivatized by antigen-antibody attachment. J Am Chem Soc 1993, 115:12264-12269.
    • (1993) J am Chem Soc , vol.115 , pp. 12264-12269
    • Bourdillon, C.1    Demaille, C.2    Gueris, J.3    Moiroux, J.4    Saveant, J.M.5
  • 2
    • 0028140806 scopus 로고
    • Step-by-step immunological construction of a fully active multilayer enzyme electrode
    • Bourdillon, C, Demaille C, Moiroux J, Saveant JM: Step-by-step immunological construction of a fully active multilayer enzyme electrode. J Am Chem Soc 1994, 116:10328-10329. This paper reports the construction of an electrode with a known number of enzyme layers. Operation of the multilayer enzyme electrode is analyzed.
    • (1994) J am Chem Soc , vol.116 , pp. 10328-10329
    • Bourdillon, C.1    Demaille, C.2    Moiroux, J.3    Saveant, J.M.4
  • 3
    • 0001923942 scopus 로고    scopus 로고
    • Biosensors based on crosslinking biotinylated glucose oxidase by avidin
    • in press
    • Vreeke MS, Rocca P: Biosensors based on crosslinking biotinylated glucose oxidase by avidin. Electroanalysis 1996, in press.
    • (1996) Electroanalysis
    • Vreeke, M.S.1    Rocca, P.2
  • 4
    • 0029166546 scopus 로고
    • Improving enzyme electrode contacts by redox modification of cofactors
    • 2 molecule to the electrode, thereby improving the efficiency of signal transduction.
    • (1995) Nature , vol.376 , pp. 672-675
    • Riklin, A.1    Katz, E.2    Willner, I.3
  • 5
    • 0027220262 scopus 로고
    • Kinetics of glucose oxidase catalyzed electron transfer mediated by sulfur and selenium compounds
    • Kulys J, Buch-Rasmussen T, Bechgaard K: Kinetics of glucose oxidase catalyzed electron transfer mediated by sulfur and selenium compounds. FEBS Lett 1993, 329:205-209.
    • (1993) FEBS Lett , vol.329 , pp. 205-209
    • Kulys, J.1    Buch-Rasmussen, T.2    Bechgaard, K.3
  • 6
    • 0029256659 scopus 로고
    • An assessment of mediators as oxidants for glucose oxldase in the presence of oxygen
    • Martens N, Hindle A, Hall EAH: An assessment of mediators as oxidants for glucose oxldase in the presence of oxygen. Biosens Bioelectron 1995, 10:393-403.
    • (1995) Biosens Bioelectron , vol.10 , pp. 393-403
    • Martens, N.1    Hindle, A.2    Hall, E.A.H.3
  • 7
    • 0029637641 scopus 로고
    • Effect of quaternization on electron diffusion coefficients for redox hydrogels based on poly(4vinylpyridine)
    • Aoki A, Rajagopalan R, Heller A: Effect of quaternization on electron diffusion coefficients for redox hydrogels based on poly(4vinylpyridine). J Phys Chem 1995, 99:5102-5110. Establishes that electron conduction in redox hydrogels originates from electron-transferring collisions between mobile polymer chain segments. Such knowledge is important to biosensor design.
    • (1995) J Phys Chem , vol.99 , pp. 5102-5110
    • Aoki, A.1    Rajagopalan, R.2    Heller, A.3
  • 8
    • 0028041728 scopus 로고
    • Electrostatic control of the electron transfer enabling binding of recombinant glucose oxidase and redox polyelectrolytes
    • 2 centers of enzymes are efficiently connected to electrodes via redox hydrogels when the enzyme protein and the polymer of the hydrogel are oppositely charged.
    • (1994) J am Chem Soc , vol.116 , pp. 3617-3618
    • Katakis, I.1    Ye, L.2    Heller, A.3
  • 9
    • 0001876153 scopus 로고
    • A new microchemlcal approach to amperometric analysis
    • Talbott J, Jordan J: A new microchemlcal approach to amperometric analysis. Microchem J 1988, 37:5-12.
    • (1988) Microchem J , vol.37 , pp. 5-12
    • Talbott, J.1    Jordan, J.2
  • 10
    • 0028925986 scopus 로고
    • Highly selective biosensing of lactate at lactate oxidase containing rhodium-dispersed carbon paste electrodes
    • Wang J, Chen O, Pedrero M: Highly selective biosensing of lactate at lactate oxidase containing rhodium-dispersed carbon paste electrodes. Anal Chim Acta 1995, 304:41-46.
    • (1995) Anal Chim Acta , vol.304 , pp. 41-46
    • Wang, J.1    Chen, O.2    Pedrero, M.3
  • 11
    • 0001635138 scopus 로고
    • Highly selective and sensitive amperometric biosensing of glucose at ruthenium-dispersed carbon paste enzyme electrodes
    • Wang J, Fang L, Lopez D, Tobias H: Highly selective and sensitive amperometric biosensing of glucose at ruthenium-dispersed carbon paste enzyme electrodes. Anal Lett 1093, 26:1819-1630.
    • (1093) Anal Lett , vol.26 , pp. 1819-11630
    • Wang, J.1    Fang, L.2    Lopez, D.3    Tobias, H.4
  • 12
    • 0000813748 scopus 로고
    • Application of 'wired' peroxidase electrodes for peroxide determination in liquid chromatography coupled to oxidase immobilized enzyme reactors
    • Yang L, Janle E, Huang T, Gitzen J, Kissinger PT, Vreeke M, Heller A: Application of 'wired' peroxidase electrodes for peroxide determination in liquid chromatography coupled to oxidase immobilized enzyme reactors. Anal Chem 1995, 67:1326-1331. A horseradish peroxidase electrode, wired using a redox hydrogel, is compared with one with a plain platinum surface. The wired electrode outperforms the platinum electrode because it is not subject to fouling, it has a better detection efficiency and it exhibits an enhanced signal-to-noise ratio.
    • (1995) Anal Chem , vol.67 , pp. 1326-1331
    • Yang, L.1    Janle, E.2    Huang, T.3    Gitzen, J.4    Kissinger, P.T.5    Vreeke, M.6    Heller, A.7
  • 13
    • 0027917769 scopus 로고
    • Amperometric monitoring of chemical secretions from individual pancreatic beta cells
    • Kennedy RT, Huang L, Atkinson MA, Dush P: Amperometric monitoring of chemical secretions from individual pancreatic beta cells. Anal Chem 1993, 65:1882-1887.
    • (1993) Anal Chem , vol.65 , pp. 1882-1887
    • Kennedy, R.T.1    Huang, L.2    Atkinson, Ma.3    Dush, P.4
  • 15
    • 0027918431 scopus 로고
    • SECM 24 enzyme microelectrodes for the measurement of hydrogen peroxide at surfaces
    • Horrocks BR, Schmidtke D, Heller A, Bard AJ: SECM 24 enzyme microelectrodes for the measurement of hydrogen peroxide at surfaces. Anal Chem 1993, 65:3605-3614.
    • (1993) Anal Chem , vol.65 , pp. 3605-3614
    • Horrocks, B.R.1    Schmidtke, D.2    Heller, A.3    Bard, A.J.4
  • 16
    • 0001120298 scopus 로고
    • Direct electrical detection of dissolved biotinylated horseradish peroxidase, biotin and avidin
    • 2 electroreduction current.
    • (1995) Anal Chem , vol.67 , pp. 303-306
    • Vreeke, M.1    Rocca, P.2    Heller, A.3
  • 17
    • 0028297886 scopus 로고
    • Electrochemical enzyme immunoassay using sequential saturation technique in a 20 μL capillary digoxin as a model analyts
    • Kaneki N, Xu Y, Kumari A, Halsall HB, Heineman WR, Kissinger PT: Electrochemical enzyme immunoassay using sequential saturation technique in a 20 μL capillary digoxin as a model analyts. Anal Chim Acta 1994, 287:253-258. Immunoassays with amperometric detection can be used to determine very small amounts of antigen or antibody in a sample. This report demonstrates an amperometric immunoassay in a 20 μl volume.
    • (1994) Anal Chim Acta , vol.287 , pp. 253-258
    • Kaneki, N.1    Xu, Y.2    Kumari, A.3    Halsall, H.B.4    Heineman, W.R.5    Kissinger, P.T.6
  • 18
    • 0001588118 scopus 로고
    • Capillary enzyme immunoassay with electrochemical detection for the determination of atrazine in water
    • Jiang T, Halsall HB, Heineman WR, Giersch T, Hock B: Capillary enzyme immunoassay with electrochemical detection for the determination of atrazine in water. J Agric Food Chem 1995, 43:1098-1104. These authors utilize a sandwich immunoassay with amperometric detection to determine atrazine levels in water. The system is capable of detecting an unprecedentedly small number of atrazine molecules in a sample.
    • (1995) J Agric Food Chem , vol.43 , pp. 1098-1104
    • Jiang, T.1    Halsall, H.B.2    Heineman, W.R.3    Giersch, T.4    Hock, B.5
  • 20
    • 0028232048 scopus 로고
    • Separation-free sandwich enzyme immunoassays using microporous gold electrodes and self-assembled monolayer/immobilized capture antibodies
    • See annotation for [21•]
    • Duan C, Meyerhoff ME: Separation-free sandwich enzyme immunoassays using microporous gold electrodes and self-assembled monolayer/immobilized capture antibodies. Anal Chem 1994, 66:1369-1377. See annotation for [21•].
    • (1994) Anal Chem , vol.66 , pp. 1369-1377
    • Duan, C.1    Meyerhoff, M.E.2
  • 21
    • 0010242880 scopus 로고
    • Immobilization of proteins on gold coated porous membranes via an activated self-assembled monolayer of thioctic acid
    • Duan C, Meyerhoff ME: Immobilization of proteins on gold coated porous membranes via an activated self-assembled monolayer of thioctic acid. Mikrochim Acta 1995, 117:195-206. This paper and [20•] introduce an amperometric immunosensor employing a sandwich immunoassay in a two-compartment cell. The method has the significant advantage of avoiding the need for rinsing.
    • (1995) Mikrochim Acta , vol.117 , pp. 195-206
    • Duan, C.1    Meyerhoff, M.E.2
  • 22
    • 0027668945 scopus 로고
    • Sequence-selective biosensor for DNA based on electroactive hybridization indicators
    • Millan KM, Mikkelsen SR: Sequence-selective biosensor for DNA based on electroactive hybridization indicators. Anal Chem 1993, 65:2317-2323.
    • (1993) Anal Chem , vol.65 , pp. 2317-2323
    • Millan, K.M.1    Mikkelsen, S.R.2
  • 23
    • 0027967657 scopus 로고
    • Voltammetric DNa biosensor for cystic fibrosis based on a modified carbon paste electrode
    • Millan KM, Saraullo A, Mikkelsen SR: Voltammetric DNA biosensor for cystic fibrosis based on a modified carbon paste electrode. Anal Chem 1994, 66:2943-2948. Voltammetric detection is used to monitor hybridization of a probe to a DNA sequence. In this case, the technique is used to detect a gene associated with disease (i.e. cystic fibrosis).
    • (1994) Anal Chem , vol.66 , pp. 2943-2948
    • Millan, K.M.1    Saraullo, A.2    Mikkelsen, S.R.3
  • 24
    • 0028325105 scopus 로고
    • Novel DNA sensor for electrochemical gene detection
    • Hashimoto K, Ito K, Ishimori Y: Novel DNA sensor for electrochemical gene detection. Anal Chim Acta 1994, 286:219-224.
    • (1994) Anal Chim Acta , vol.286 , pp. 219-224
    • Hashimoto, K.1    Ito, K.2    Ishimori, Y.3
  • 25
    • 0027370108 scopus 로고
    • The effect of intensive insulin treatment of diabetes on the development and progression of long-term complications in insulin dependent diabetes mellitus
    • Diabetes Control and Complications Trial Research Group: The effect of intensive insulin treatment of diabetes on the development and progression of long-term complications in insulin dependent diabetes mellitus. N Engl J Med 1993, 329:977-986.
    • (1993) N Engl J Med , vol.329 , pp. 977-986
    • Control, D.1
  • 26
    • 0027524872 scopus 로고
    • Clinical review 51. Implications of the diabetes control and complications trial
    • Eastman RC, Siebert CW, Harris M, Gordon P: Clinical review 51. Implications of the diabetes control and complications trial. J Clin Endocrinol Meteb 1993, 77:1105.
    • (1993) J Clin Endocrinol Meteb , vol.77 , pp. 1105
    • Eastman, R.C.1    Siebert, C.W.2    Harris, M.3    Gordon, P.4
  • 27
    • 0028272196 scopus 로고
    • Reduction of acetaminophen interference in glucose sensors by a composite Nation membrane: Demonstration in rats and man
    • Moatti-Sirat D, Poitout V, Thome V, Gangnerau MN, Zhang Y, Hu Y, Wilson GS, Lemonnier F, Klein JC, Reach G: Reduction of acetaminophen interference in glucose sensors by a composite Nation membrane: demonstration in rats and man. Diabetologia 1994, 37:610-616. These authors improve the sensitivity of an in vivo glucose sensor through the use of a novel composite membrane. This membrane reduces signal interference by acetaminophen.
    • (1994) Diabetologia , vol.37 , pp. 610-616
    • Moatti-Sirat, D.1    Poitout, V.2    Thome, V.3    Gangnerau, M.N.4    Zhang, Y.5    Hu, Y.6    Wilson, G.S.7    Lemonnier, F.8    Klein, J.C.9    Reach, G.10
  • 28
    • 0026216348 scopus 로고
    • Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
    • Bindra DS, Zhang Y, Wilson GS: Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring. Anal Chem 1991, 63:1692-1696.
    • (1991) Anal Chem , vol.63 , pp. 1692-1696
    • Bindra, D.S.1    Zhang, Y.2    Wilson, G.S.3
  • 29
    • 0028418786 scopus 로고
    • Elimination of the acetaminophen interference in an implantable glucose sensor
    • Zhang Y, Hu Y, Wilson GS, Moatti-Sirat D, Poitout V, Reach G: Elimination of the acetaminophen interference in an implantable glucose sensor. Anal Chem 1994, 66:1183-1188.
    • (1994) Anal Chem , vol.66 , pp. 1183-1188
    • Zhang, Y.1    Hu, Y.2    Wilson, G.S.3    Moatti-Sirat, D.4    Poitout, V.5    Reach, G.6
  • 30
    • 0026546742 scopus 로고
    • Towards continuous glucose monitoring: In vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue
    • Moatti-Sirat D, Capron F, Poitoul V, Reach G, Bindra DS, Zhang Y, Wilson GS, Thévenot DR: Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue. Diabetologia 1992, 36:224-230.
    • (1992) Diabetologia , vol.36 , pp. 224-230
    • Moatti-Sirat, D.1    Capron, F.2    Poitoul, V.3    Reach, G.4    Bindra, D.S.5    Zhang, Y.6    Wilson, G.S.7    Thévenot, D.R.8
  • 31
    • 0027214964 scopus 로고
    • A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit
    • Poitout V, Moatti-Sirat D, Reach G, Zhang Y, Wilson GS, Lemonnier F, Klein JC: A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit. Diabetologia 1993, 36:668-663.
    • (1993) Diabetologia , vol.36 , pp. 668-1663
    • Poitout, V.1    Moatti-Sirat, D.2    Reach, G.3    Zhang, Y.4    Wilson, G.S.5    Lemonnier, F.6    Klein, J.C.7
  • 32
    • 0028533426 scopus 로고
    • In vitro and in vivo performance and lifetime of perfluorinated ionomer-coated glucose sensors after high-temperature curing
    • Moussy F, Jakeway S, Harrison DJ, Rajotte RV: In vitro and in vivo performance and lifetime of perfluorinated ionomer-coated glucose sensors after high-temperature curing. Anal Chem 1994, 66:3882-3888. A glucose-sensing electrode is prepared by curing at a temperature exceeding 100°C. Curing enhances the performance of the perfluorinated ionomer coaled electrode.
    • (1994) Anal Chem , vol.66 , pp. 3882-3888
    • Moussy, F.1    Jakeway, S.2    Harrison, D.J.3    Rajotte, R.V.4
  • 33
    • 0028183143 scopus 로고
    • A miniaturized Nation-based glucose sensor: In vitro and in vivo evaluation in dogs
    • Moussy F, Harrison DJ, Rajotte RV: A miniaturized Nation-based glucose sensor: in vitro and in vivo evaluation in dogs. Int J Artif Organs 1994, 17:89-94.
    • (1994) Int J Artif Organs , vol.17 , pp. 89-94
    • Moussy, F.1    Harrison, D.J.2    Rajotte, R.V.3
  • 34
    • 0028394265 scopus 로고
    • Prevention of the rapid degradation of subcutaneously Implanted Ag/AgCl reference electrodes using polymer coatings
    • Moussy F, Harrison DJ: Prevention of the rapid degradation of subcutaneously Implanted Ag/AgCl reference electrodes using polymer coatings. Anal Chem 1994, 66:674-679. These authors show that the Ag/AgCl reference/counter electrode is stabilized by overcoating with Nation™ and high-temperature curing (see also [32•]).
    • (1994) Anal Chem , vol.66 , pp. 674-679
    • Moussy, F.1    Harrison, D.J.2
  • 35
    • 84987476988 scopus 로고
    • Reduction of electrooxidizable interferent effects: Optimization of the applied potential for amperometric glucose sensors
    • Johnson KW, Bryan-Poole N, Mastrototaro JJ: Reduction of electrooxidizable interferent effects: optimization of the applied potential for amperometric glucose sensors. Electroanalysis 1994, 6:321-326.
    • (1994) Electroanalysis , vol.6 , pp. 321-326
    • Johnson, K.W.1    Bryan-Poole, N.2    Mastrototaro, J.J.3
  • 37
    • 0029287405 scopus 로고
    • Design and optimization of a selective subcutaneously implantable glucose electrode based on 'wired' glucose oxidase
    • Csöregi E, Schmidtke DW, Heller A: Design and optimization of a selective subcutaneously implantable glucose electrode based on 'wired' glucose oxidase. Anal Chem 1995, 67:1240-1244. This paper and [36•] show that an implanted glucose electrode can be calibrated by assaying a single sample of blood. The electrode is a 0.3 mm plastically deformable microwire.
    • (1995) Anal Chem , vol.67 , pp. 1240-1244
    • Csöregi, E.1    Schmidtke, D.W.2    Heller, A.3
  • 38
    • 0029256670 scopus 로고
    • Photo-crosslinked copolymers of 2-hydroxyethyl methacrylate, poly(ethylene glycol) tetra-acrylate and ethylene dimethacrylate for improving biocompatibility of biosensors
    • Quinn CP, Pathak CP, Heller A, Hubbell JA: Photo-crosslinked copolymers of 2-hydroxyethyl methacrylate, poly(ethylene glycol) tetra-acrylate and ethylene dimethacrylate for improving biocompatibility of biosensors. Biomaterials 1995, 16:389-396. In this study, sensors are designed with a biocompatible coating that is highly permeable to glucose. The coaling is made by photocrosslinking a tetraacrylated polyethylene oxide.
    • (1995) Biomaterials , vol.16 , pp. 389-396
    • Quinn, C.P.1    Pathak, C.P.2    Heller, A.3    Hubbell, J.A.4
  • 39
    • 0028872278 scopus 로고
    • Kinetics of glucose delivery to subcutaneous tissue in rats measured with 0.3 mm amperometric microsensors
    • Quinn CP, Pishko MV, Schmidtke DW, Ishikawa M, Wagner JG, Raskin P, Hubbell JA, Heller A: Kinetics of glucose delivery to subcutaneous tissue in rats measured with 0.3 mm amperometric microsensors. Am J Physiol 1995, 269:E155-E161. An amperometric sensor is used to study the kinetics of glucose delivery in rats. For high intravenous doses of glucose, the time delay between glucose concentration maxima in blood and subcutaneous tissue is shown to increase with the size of glucose dose, a phenomenon that results from facilitated transport.
    • (1995) Am J Physiol , vol.269
    • Quinn, C.P.1    Pishko, M.V.2    Schmidtke, D.W.3    Ishikawa, M.4    Wagner, J.G.5    Raskin, P.6    Hubbell, J.A.7    Heller, A.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.