메뉴 건너뛰기




Volumn 11, Issue 4, 1996, Pages 419-425

A microdialysis fibre based sampler for flow injection analysis: Determination of L-lactate in biofluids by an electrochemically synthesised bilayer membrane based biosensor

Author keywords

Biosensors; Flow injection analysis; L lactate; Microdialysis

Indexed keywords

AMPEROMETRIC SENSORS; AROMATIC POLYMERS; BIOSENSORS; ENZYME IMMOBILIZATION; ESTERS; FLUIDS; MOLECULAR WEIGHT; POLYMERIC MEMBRANES; SAMPLING;

EID: 0030064583     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/0956-5663(96)82737-0     Document Type: Article
Times cited : (43)

References (17)
  • 1
    • 0000629950 scopus 로고
    • Interference free glucose sensor based on glucose oxidase immobilised in an overoxidised non-conducting polypyrrole film
    • Centonze, D., Guerrieri, A., Malitesta, C., Palmisano, F. & Zambonin, P.G. (1992a). Interference free glucose sensor based on glucose oxidase immobilised in an overoxidised non-conducting polypyrrole film. Fresenius J. Anal. Chem., 342, 729-733.
    • (1992) Fresenius J. Anal. Chem. , vol.342 , pp. 729-733
    • Centonze, D.1    Guerrieri, A.2    Malitesta, C.3    Palmisano, F.4    Zambonin, P.G.5
  • 2
    • 0000299327 scopus 로고
    • An in-situ electro-synthesized poly-o-phenylenediamine/glucose oxidase amperometric biosensor for flow injection determination of glucose in serum
    • Centonze, D., Guerrieri, A., Malitesta, C., Palmisano, F. & Zambonin, P.G. (1992b). An in-situ electro-synthesized poly-o-phenylenediamine/glucose oxidase amperometric biosensor for flow injection determination of glucose in serum. Ann. Chim., (Rome), 82, 219-234.
    • (1992) Ann. Chim., (Rome) , vol.82 , pp. 219-234
    • Centonze, D.1    Guerrieri, A.2    Malitesta, C.3    Palmisano, F.4    Zambonin, P.G.5
  • 3
    • 0039633245 scopus 로고
    • Enzyme entrapment in electrically conducting polymers
    • Foulds, N.C. & Lowe, C.R. (1986). Enzyme entrapment in electrically conducting polymers. J. Chem. Soc. Faraday Trans. I, 82, 1259-1264.
    • (1986) J. Chem. Soc. Faraday Trans. I , vol.82 , pp. 1259-1264
    • Foulds, N.C.1    Lowe, C.R.2
  • 4
    • 0027199596 scopus 로고
    • A needle-type enzyme-based lactate sensor for in vivo monitoring
    • Hu, Y., Zhang, Y. & Wilson, G.S. (1993). A needle-type enzyme-based lactate sensor for in vivo monitoring. Anal. Chim. Acta, 281, 503-511.
    • (1993) Anal. Chim. Acta , vol.281 , pp. 503-511
    • Hu, Y.1    Zhang, Y.2    Wilson, G.S.3
  • 5
    • 0000814653 scopus 로고
    • Sampling living systems using microdialysis probe
    • Lunte, C.E., Scott, D.O. & Kissinger, P.T. (1991). Sampling living systems using microdialysis probe. Anal. Chem., 63, 773-780A.
    • (1991) Anal. Chem. , vol.63
    • Lunte, C.E.1    Scott, D.O.2    Kissinger, P.T.3
  • 6
    • 37049087093 scopus 로고
    • Ascorbic acid oxidation at polypyrrole-coated electrodes
    • Lyons, M.E.G. & Breen, W. (1991). Ascorbic acid oxidation at polypyrrole-coated electrodes. J. Chem. Soc. Faraday Trans., 87, 115-123.
    • (1991) J. Chem. Soc. Faraday Trans. , vol.87 , pp. 115-123
    • Lyons, M.E.G.1    Breen, W.2
  • 7
    • 0025671780 scopus 로고
    • Glucose fast response amperometric biosensor based on glucose oxidase immobilised in an electropolymerized poly(o-phenylenediamine) film
    • Malitesta, C., Palmisano, F., Torsi, L. & Zambonin, P.G. (1990). Glucose fast response amperometric biosensor based on glucose oxidase immobilised in an electropolymerized poly(o-phenylenediamine) film. Anal. Chem., 64, 2735-2740.
    • (1990) Anal. Chem. , vol.64 , pp. 2735-2740
    • Malitesta, C.1    Palmisano, F.2    Torsi, L.3    Zambonin, P.G.4
  • 8
    • 0027764609 scopus 로고
    • On line continuous monitoring of blood in men by a wearable device based upon an enzymatic amperometric lactate sensor
    • Meyerhoff, C., Bischof, F., Mennel, F.J., Sternberg, F., Bican, J. & Pfeiffer, E.F. (1993). On line continuous monitoring of blood in men by a wearable device based upon an enzymatic amperometric lactate sensor. Biosensors & Bioelectronics, 8, 409-414.
    • (1993) Biosensors & Bioelectronics , vol.8 , pp. 409-414
    • Meyerhoff, C.1    Bischof, F.2    Mennel, F.J.3    Sternberg, F.4    Bican, J.5    Pfeiffer, E.F.6
  • 10
    • 0027757187 scopus 로고
    • An interference-free biosensor based on glucose oxidase electrochemically immobilised in a non conducting poly-pyrrole film for continuous subcutaneous monitoring of glucose through microdialysis sampling
    • Palmisano, F., Centonze, D., Guerrieri, A. & Zambonin, P.G. (1993). An interference-free biosensor based on glucose oxidase electrochemically immobilised in a non conducting poly-pyrrole film for continuous subcutaneous monitoring of glucose through microdialysis sampling. Biosensors & Bioelectronics, 8, 393-399.
    • (1993) Biosensors & Bioelectronics , vol.8 , pp. 393-399
    • Palmisano, F.1    Centonze, D.2    Guerrieri, A.3    Zambonin, P.G.4
  • 11
    • 0028090182 scopus 로고
    • An in situ electrosynthesized amperometric biosensor based on lactate oxidase immobilised in a poly-o-phenylenediamine film: Determination of lactate in serum by flow injection analysis
    • Palmisano, F., Centonze, D. & Zambonin, P.G. (1994). An in situ electrosynthesized amperometric biosensor based on lactate oxidase immobilised in a poly-o-phenylenediamine film: determination of lactate in serum by flow injection analysis. Biosensors & Bioelectronics, 9, 471-479.
    • (1994) Biosensors & Bioelectronics , vol.9 , pp. 471-479
    • Palmisano, F.1    Centonze, D.2    Zambonin, P.G.3
  • 12
    • 0029275951 scopus 로고
    • Electrosynthesized bilayer polymeric membrane for effective elimination of electroactive interferents in amperometric biosensors
    • Palmisano, F., Guerrieri, A., Quinto, M. & Zambonin, P.G. (1995). Electrosynthesized bilayer polymeric membrane for effective elimination of electroactive interferents in amperometric biosensors. Anal.Chem., 67, 1005-1009.
    • (1995) Anal.Chem. , vol.67 , pp. 1005-1009
    • Palmisano, F.1    Guerrieri, A.2    Quinto, M.3    Zambonin, P.G.4
  • 14
    • 0024957569 scopus 로고
    • Microdialysis-perfusion sampling for the investigation of phenol metabolism
    • Scott, D.O., Bell, M.A. & Lunte, C.E. (1989). Microdialysis-perfusion sampling for the investigation of phenol metabolism. J. Pharm. Biom. Anal., 7, 1249-1259.
    • (1989) J. Pharm. Biom. Anal. , vol.7 , pp. 1249-1259
    • Scott, D.O.1    Bell, M.A.2    Lunte, C.E.3
  • 15
    • 0025732687 scopus 로고
    • Pharmacokinetic studies of aspirin in rats using in vivo microdialysis sampling
    • Steele, K.L., Scott, D.O. & Lunte, C.E. (1991). Pharmacokinetic studies of aspirin in rats using in vivo microdialysis sampling. Anal. Chim. Acta, 246, 181-186.
    • (1991) Anal. Chim. Acta , vol.246 , pp. 181-186
    • Steele, K.L.1    Scott, D.O.2    Lunte, C.E.3
  • 16
    • 0027665848 scopus 로고
    • Examination of microdialysis in a well-characterized hydrodynamic system
    • Stenken, J.A., Topp, E.M., Southard, M.Z. & Lunte, C.E. (1993). Examination of microdialysis in a well-characterized hydrodynamic system. Anal. Chem., 65, 2324-2328.
    • (1993) Anal. Chem. , vol.65 , pp. 2324-2328
    • Stenken, J.A.1    Topp, E.M.2    Southard, M.Z.3    Lunte, C.E.4
  • 17
    • 33845374035 scopus 로고
    • Protein-modified electrodes. The glucose oxidase/polypyrrole system
    • Umana, M. & Waller, J. (1986). Protein-modified electrodes. The glucose oxidase/polypyrrole system. Anal. Chem., 58, 2979-2983.
    • (1986) Anal. Chem. , vol.58 , pp. 2979-2983
    • Umana, M.1    Waller, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.