메뉴 건너뛰기




Volumn 6, Issue 1, 1996, Pages 51-58

Current status of the glucose sensor

Author keywords

[No Author keywords available]

Indexed keywords

GLUCOSE; GLUCOSE OXIDASE; INSULIN;

EID: 0030054006     PISSN: 10512144     EISSN: None     Source Type: Journal    
DOI: 10.1097/00019616-199601000-00008     Document Type: Review
Times cited : (15)

References (29)
  • 1
    • 9044241872 scopus 로고
    • Biosensors
    • Schultz JS: Biosensors. Sci Am 1991; pp. 48-55.
    • (1991) Sci Am , pp. 48-55
    • Schultz, J.S.1
  • 2
    • 84942558425 scopus 로고
    • Monitor and control of blood and tissue oxygen tension
    • Clark LC: Monitor and control of blood and tissue oxygen tension. Trans Am Soc Artif Intern Organs 1956; 2: 41-8.
    • (1956) Trans Am Soc Artif Intern Organs , vol.2 , pp. 41-48
    • Clark, L.C.1
  • 3
    • 0014191637 scopus 로고
    • The enzyme electrode
    • Updike SJ, G Hicks: The enzyme electrode. Nature 1967; 214: 986-8.
    • (1967) Nature , vol.214 , pp. 986-988
    • Updike, S.J.1    Hicks, G.2
  • 4
    • 0016259390 scopus 로고
    • The artificial β-cell. A continuous control of blood sugar by external reglation of insulin infusion (glucose-controlled-insulin-infusion-system)
    • Pfeiffer EF, Thum C, Clemens AR: The artificial β-cell. A continuous control of blood sugar by external reglation of insulin infusion (glucose-controlled-insulin-infusion-system). Horm Metab Res 1974; 6: 339-42.
    • (1974) Horm Metab Res , vol.6 , pp. 339-342
    • Pfeiffer, E.F.1    Thum, C.2    Clemens, A.R.3
  • 6
    • 0020402631 scopus 로고
    • Wearable artificial endocrine pancreas with needle-type glucose sensor
    • Shichiri M, Kawamori R, Yamasaki Y, Hakui N, Abe H: Wearable artificial endocrine pancreas with needle-type glucose sensor. Lancet 1982; 2: 1129-31.
    • (1982) Lancet , vol.2 , pp. 1129-1131
    • Shichiri, M.1    Kawamori, R.2    Yamasaki, Y.3    Hakui, N.4    Abe, H.5
  • 7
    • 0022018228 scopus 로고
    • Electrochemical sensors in clinical chemistry: Yesterday, today, tomorrow
    • Czaban JD: Electrochemical sensors in clinical chemistry: yesterday, today, tomorrow. Anal Chem 1985; 57: 345A-365A.
    • (1985) Anal Chem , vol.57
    • Czaban, J.D.1
  • 11
    • 0025327060 scopus 로고
    • Progress in practical endocrinology. The Glucosensor Unitec Ulm - A portable monitor for continuous blood glucose measurement
    • Brückel J, Zier H, Kemer W, Pfeiffer EF: Progress in practical endocrinology. The Glucosensor Unitec Ulm - a portable monitor for continuous blood glucose measurement. Horm Metab Res 1990; 22: 382-4.
    • (1990) Horm Metab Res , vol.22 , pp. 382-384
    • Brückel, J.1    Zier, H.2    Kemer, W.3    Pfeiffer, E.F.4
  • 12
    • 0021148018 scopus 로고
    • Experience with an implantable glucose sensor as a prerequisite of an artificial β cell
    • Abel P, Müller A, Fischer U: Experience with an implantable glucose sensor as a prerequisite of an artificial β cell. Biomed Biochim Acta 1984; 43: 577-84.
    • (1984) Biomed Biochim Acta , vol.43 , pp. 577-584
    • Abel, P.1    Müller, A.2    Fischer, U.3
  • 13
    • 0024235567 scopus 로고
    • A potentially implantable enzyme electrode for amperometric measurement of glucose
    • Kemer W, Zier H, Steinback G, Brückel J, et al.: A potentially implantable enzyme electrode for amperometric measurement of glucose. Horm Metab Res (Suppl Ser) 1988; 20: 8-13.
    • (1988) Horm Metab Res , vol.20 , Issue.SUPPL. SER , pp. 8-13
    • Kemer, W.1    Zier, H.2    Steinback, G.3    Brückel, J.4
  • 14
    • 0026546742 scopus 로고
    • Towards continuous glucose monitoring: In-vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue
    • Moatti-Sirat D, Capron F, Poitout V, et al.: Towards continuous glucose monitoring: in-vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue. Diabetologia 1992; 305: 224-30.
    • (1992) Diabetologia , vol.305 , pp. 224-230
    • Moatti-Sirat, D.1    Capron, F.2    Poitout, V.3
  • 15
    • 0027770788 scopus 로고
    • Responses and calibration of amperometric glucose sensors implanted in the subcutaneous tissue of man
    • Pickup JC, Claremont DJ, Shaw GW: Responses and calibration of amperometric glucose sensors implanted in the subcutaneous tissue of man. Acta Diabetol 1993; 30: 143-8.
    • (1993) Acta Diabetol , vol.30 , pp. 143-148
    • Pickup, J.C.1    Claremont, D.J.2    Shaw, G.W.3
  • 16
    • 1842370264 scopus 로고
    • The artificial pancreas
    • edited by Rifkin, H, Colwell JA, Taylor SI. New York, Elsevier Science Publishers
    • Pfeiffer EF: The artificial pancreas. In Diabetes 1991, edited by Rifkin, H, Colwell JA, Taylor SI. New York, Elsevier Science Publishers.
    • (1991) Diabetes
    • Pfeiffer, E.F.1
  • 17
    • 0027746317 scopus 로고
    • The function of a hydrogen peroxide-detecting electroenzymatic glucose electrode is markedly impaired in human subcutaneous tissue and plasma
    • Kerner W, Kiwitt M, Linke B, Keck FS, Zier H, Pfeiffer EF: The function of a hydrogen peroxide-detecting electroenzymatic glucose electrode is markedly impaired in human subcutaneous tissue and plasma. Biosens Bioelectronics 1993; 8: 473-82.
    • (1993) Biosens Bioelectronics , vol.8 , pp. 473-482
    • Kerner, W.1    Kiwitt, M.2    Linke, B.3    Keck, F.S.4    Zier, H.5    Pfeiffer, E.F.6
  • 18
    • 0013974050 scopus 로고
    • The concentrations of free amino acids and other electrolytes in cerebrospinal fluid, in vivo dialysate of brain and blood plasma in the dog
    • Bito L, Davison H, Levin E, Murray M, Snider N: The concentrations of free amino acids and other electrolytes in cerebrospinal fluid, in vivo dialysate of brain and blood plasma in the dog. J Neurochem 1966; 13: 1057-67.
    • (1966) J Neurochem , vol.13 , pp. 1057-1067
    • Bito, L.1    Davison, H.2    Levin, E.3    Murray, M.4    Snider, N.5
  • 20
    • 0026354548 scopus 로고
    • Combination of microdialysis and glcuosensor permits continuous (on line) s.c. glucose monitoring in a patient operated device. I. In vitro evaluation
    • Keck FS, Kemer W, Meyerhoff C, Zier H, Pfeiffer EF: Combination of microdialysis and glcuosensor permits continuous (on line) s.c. glucose monitoring in a patient operated device. I. In vitro evaluation. Horm Metab Res 1991; 23: 617-8.
    • (1991) Horm Metab Res , vol.23 , pp. 617-618
    • Keck, F.S.1    Kemer, W.2    Meyerhoff, C.3    Zier, H.4    Pfeiffer, E.F.5
  • 21
    • 0026761167 scopus 로고
    • On line continuous monitoring of subcutaneous tissue glucose in man by combining portable glucosensor with microdialysis
    • Meyerhoff C, Bischof F, Stemberg F, Zier H, Pfeiffer EF: On line continuous monitoring of subcutaneous tissue glucose in man by combining portable glucosensor with microdialysis. Diabetologia 1992; 35: 1087-92.
    • (1992) Diabetologia , vol.35 , pp. 1087-1092
    • Meyerhoff, C.1    Bischof, F.2    Stemberg, F.3    Zier, H.4    Pfeiffer, E.F.5
  • 22
    • 0027474090 scopus 로고
    • On line continuous monitoring of subcutaneous tissue glucose is feasible by combining portable glucosensor with microdialysis
    • Pfeiffer EF, Meyerhoff C, Bischof F, Keck FS, Kemer W: On line continuous monitoring of subcutaneous tissue glucose is feasible by combining portable glucosensor with microdialysis. Horm Metab Res 1993; 25: 121-4.
    • (1993) Horm Metab Res , vol.25 , pp. 121-124
    • Pfeiffer, E.F.1    Meyerhoff, C.2    Bischof, F.3    Keck, F.S.4    Kemer, W.5
  • 23
    • 85035157792 scopus 로고
    • Thesis in preparation
    • Sternberg F: Thesis 1994 (in preparation).
    • (1994)
    • Sternberg, F.1
  • 24
    • 0028019058 scopus 로고
    • The "Ulm Zucker Uhr System" and its consequences
    • Pfeiffer EF: The "Ulm Zucker Uhr System" and its consequences. Horm Metab Res 1994; 26: 510-4.
    • (1994) Horm Metab Res , vol.26 , pp. 510-514
    • Pfeiffer, E.F.1
  • 26
    • 0025051997 scopus 로고
    • Steady-state theory for quantitative microdialysis of solutes and water in vivo and in vitro
    • Bungay PM, Morrison PF, Dendrick RF: Steady-state theory for quantitative microdialysis of solutes and water in vivo and in vitro. Life Sci 1990; 46: 105-19.
    • (1990) Life Sci , vol.46 , pp. 105-119
    • Bungay, P.M.1    Morrison, P.F.2    Dendrick, R.F.3
  • 27
    • 0028109468 scopus 로고
    • Combination of microdialysis and glucose sensor for continuous on line measurement of the subcutaneous glucose concentration: Theory and practical application
    • Meyerhoff C, Mennel FJ, Bischof F, Sternberg F, Pfeiffer EF: Combination of microdialysis and glucose sensor for continuous on line measurement of the subcutaneous glucose concentration: theory and practical application. Horm Metab Res 1994; 26: 538-43.
    • (1994) Horm Metab Res , vol.26 , pp. 538-543
    • Meyerhoff, C.1    Mennel, F.J.2    Bischof, F.3    Sternberg, F.4    Pfeiffer, E.F.5
  • 28
    • 0028061426 scopus 로고
    • Calibration problems of subcutaneous glucosensors when applied "in-situ" in man
    • Stemberg F, Meyerhoff C, Mennel FJ, et al.: Calibration problems of subcutaneous glucosensors when applied "in-situ" in man. Horm Metab Res 1994; 26: 523-5.
    • (1994) Horm Metab Res , vol.26 , pp. 523-525
    • Stemberg, F.1    Meyerhoff, C.2    Mennel, F.J.3
  • 29
    • 0026668743 scopus 로고
    • Noninvasive glucose monitoring in diabetic patients: A preliminary evaluation
    • Robinson MR, Eaton RP, Haaland DM, et al.: Noninvasive glucose monitoring in diabetic patients: a preliminary evaluation. Clin Chem 1992; 38: 1618-22.
    • (1992) Clin Chem , vol.38 , pp. 1618-1622
    • Robinson, M.R.1    Eaton, R.P.2    Haaland, D.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.