Volumn 69, Issue 817, 1996, Pages 42-48

Comparative study of dose values and image quality in mammography in the Madrid area

Author keywords

[No Author keywords available]

Indexed keywords

ALUMINUM;

EID: 0030051323     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/0007-1285-69-817-42     Document Type: Review
Times cited : (2)

References (15)
  • 1
    • 0028355701 scopus 로고
    • Comparative study of dose values and image quality in mammography in the area of Madrid
    • MORÁN P, CHEVALIER, M and VAÑÓ, E, Comparative study of dose values and image quality in mammography in the area of Madrid, Br. J. Radiol., 67, 556-563 (1994)
    • (1994) Br. J. Radiol. , vol.67 , pp. 556-563
    • Morán, P.1    Chevalier, M.2    Vañó, E.3
  • 2
    • 2842602247 scopus 로고
    • European protocol for the quality control of the technical aspects of mammography screening
    • ed. by C J M de Wolf (CEC, Brussels)
    • COMMISSION OF THE EUROPEAN COMMUNITIES, European protocol for the quality control of the technical aspects of mammography screening. In European Guidelines for Quality Assurance in Mammography Screening (CEC Report EUR 14821 EN), ed. by C J M de Wolf (CEC, Brussels) (1993).
    • (1993) European Guidelines for Quality Assurance in Mammography Screening (CEC Report EUR 14821 EN)
  • 6
    • 4244035311 scopus 로고
    • Design of test objects and phantoms for quality control in mammography
    • IPSM, York
    • COWEN, A R and COLEMAN, N J, Design of test objects and phantoms for quality control in mammography. In Physics in Diagnostic Radiology (IPSM Report 61) (IPSM, York), pp. 30-36 (1990).
    • (1990) Physics in Diagnostic Radiology (IPSM Report 61) , pp. 30-36
    • Cowen, A.R.1    Coleman, N.J.2
  • 7
    • 0027445529 scopus 로고
    • Evaluation of the sensitivity of the Leeds TOR(MAX) mammographic phantom
    • MORAN, P, CHEVALIER, M, CONTENTO, G and VAÑÓ, E, Evaluation of the sensitivity of the Leeds TOR(MAX) mammographic phantom, Radiat. Prot. Dosim., 49, 163-166 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.49 , pp. 163-166
    • Moran, P.1    Chevalier, M.2    Contento, G.3    Vañó, E.4
  • 8
    • 0023069484 scopus 로고
    • A comparative study of films and screens for mammography
    • KIRKPATRICK, A E and LAW, J, A comparative study of films and screens for mammography, Br. J. Radiol., 60, 73-78 (1987).
    • (1987) Br. J. Radiol. , vol.60 , pp. 73-78
    • Kirkpatrick, A.E.1    Law, J.2
  • 9
    • 0025278027 scopus 로고
    • Standardization of image quality and radiation dose in mammography
    • HENDRICK, E, Standardization of image quality and radiation dose in mammography, Radiology, 174, 648-654 (1990).
    • (1990) Radiology , vol.174 , pp. 648-654
    • Hendrick, E.1
  • 12
    • 0027190827 scopus 로고
    • The influence of focal spot size on image resolution and test phantom scores in mammography
    • LAW, J, The influence of focal spot size on image resolution and test phantom scores in mammography, Br. J. Radiol., 66, 441-446 (1993).
    • (1993) Br. J. Radiol. , vol.66 , pp. 441-446
    • Law, J.1
  • 13
    • 0023911840 scopus 로고
    • Focal spot size measurements with pinhole and slit for microfocus mammography units
    • KIMME-SMITH, C, BASSET, L W and GOLD, R H, Focal spot size measurements with pinhole and slit for microfocus mammography units, Med. Phys., 15, 298-303 (1988).
    • (1988) Med. Phys. , vol.15 , pp. 298-303
    • Kimme-Smith, C.1    Basset, L.W.2    Gold, R.H.3
  • 14
    • 0027418732 scopus 로고
    • Measurement of focal spot size in mammography X-ray tubes
    • LAW, J, Measurement of focal spot size in mammography X-ray tubes, Br. J. Radiol., 66, 44-50 (1993).
    • (1993) Br. J. Radiol. , vol.66 , pp. 44-50
    • Law, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.