-
1
-
-
0025939771
-
T1-weighted snapshot gradient-echo MR imaging of the abdomen
-
A. F. Holsinger-Bampton, S. J. Riederer, N. G. Campeau, R. L. Ehman, C. D. Johnson, T1-weighted snapshot gradient-echo MR imaging of the abdomen. Radiology 181, 25-32 (1991).
-
(1991)
Radiology
, vol.181
, pp. 25-32
-
-
Holsinger-Bampton, A.F.1
Riederer, S.J.2
Campeau, N.G.3
Ehman, R.L.4
Johnson, C.D.5
-
2
-
-
0028204966
-
MR imaging of the liver: Breath-hold Tl-weighted MP-GRE compared with conventional T2-weighted SE imaging - Lesion detection, localization, and characterization
-
E. E. de Lange, J. P. Mugler III, J. E. Bosworth, G. A. DeAngelis, S. B. Gay, N. S. Hurt, S. S. Berr, J. M. Rosenblatt, L. W. Merickel, E. K. Harris, MR imaging of the liver: breath-hold Tl-weighted MP-GRE compared with conventional T2-weighted SE imaging - lesion detection, localization, and characterization. Radiology 190, 727-736 (1994).
-
(1994)
Radiology
, vol.190
, pp. 727-736
-
-
De Lange, E.E.1
Mugler III, J.P.2
Bosworth, J.E.3
Deangelis, G.A.4
Gay, S.B.5
Hurt, N.S.6
Berr, S.S.7
Rosenblatt, J.M.8
Merickel, L.W.9
Harris, E.K.10
-
3
-
-
0026571435
-
MP-RAGE: A three-dimensional, T1-weighted, gradient-echo sequence - Initial experience in the brain
-
M. Brant-Zawadzki, G. D. Gillan, W. R. Nitz, MP-RAGE: a three-dimensional, T1-weighted, gradient-echo sequence - initial experience in the brain. Radiology 182, 769-775 (1992).
-
(1992)
Radiology
, vol.182
, pp. 769-775
-
-
Brant-Zawadzki, M.1
Gillan, G.D.2
Nitz, W.R.3
-
4
-
-
0028351561
-
Inversion in the steady state: Contrast optimization and reduced imaging time with fast three-dimensional inversion-recovery - Prepared GRE pulse sequences
-
T. K. F. Foo, A. M. Sawyer, W. H. Faulkner, D. G. Mills, Inversion in the steady state: contrast optimization and reduced imaging time with fast three-dimensional inversion-recovery - prepared GRE pulse sequences. Radiology 191, 85-90 (1994).
-
(1994)
Radiology
, vol.191
, pp. 85-90
-
-
Foo, T.K.F.1
Sawyer, A.M.2
Faulkner, W.H.3
Mills, D.G.4
-
5
-
-
0026855792
-
Optimization of three-dimensional T1-weighted gradient-echo imaging of the cervical spine
-
J. S. Ross, J. A. Tkach, J. Dillinger, P. M. Ruggieri, T. J. Masaryk, M. T. Modic, Optimization of three-dimensional T1-weighted gradient-echo imaging of the cervical spine. J. Magn. Reson. Imaging 2, 359-364 (1992).
-
(1992)
J. Magn. Reson. Imaging
, vol.2
, pp. 359-364
-
-
Ross, J.S.1
Tkach, J.A.2
Dillinger, J.3
Ruggieri, P.M.4
Masaryk, T.J.5
Modic, M.T.6
-
6
-
-
0025961482
-
Cineangiography of the heart in a single breath hold with a segmented TurboFLASH sequence
-
D. J. Atkinson, R. R. Edelman, Cineangiography of the heart in a single breath hold with a segmented TurboFLASH sequence. Radiology 178, 357-360 (1991).
-
(1991)
Radiology
, vol.178
, pp. 357-360
-
-
Atkinson, D.J.1
Edelman, R.R.2
-
7
-
-
0025228410
-
0.3-second FLASH MRI of the human heart
-
J. Frahm, K. D Merboldt, M. L. Gyngell, W. Hanicke, D. Chien, 0.3-second FLASH MRI of the human heart. Magn. Reson. Med. 13, 150-157 (1990).
-
(1990)
Magn. Reson. Med.
, vol.13
, pp. 150-157
-
-
Frahm, J.1
Merboldt, K.D.2
Gyngell, M.L.3
Hanicke, W.4
Chien, D.5
-
8
-
-
0027280275
-
Coronary arteries: Three-dimensional MR imaging with fat saturation and magnetization transfer contrast
-
D. Li, C. B. Paschal, E. M. Haacke, L. P. Adler, Coronary arteries: three-dimensional MR imaging with fat saturation and magnetization transfer contrast. Radiology 187, 401-406 (1993).
-
(1993)
Radiology
, vol.187
, pp. 401-406
-
-
Li, D.1
Paschal, C.B.2
Haacke, E.M.3
Adler, L.P.4
-
9
-
-
0026316572
-
Coronary arteries: Breath-hold MR angiography
-
R. R. Edelman, W. J. Manning, D. Burstein, S. Paulin, Coronary arteries: breath-hold MR angiography. Radiology 181, 641-643 (1991).
-
(1991)
Radiology
, vol.181
, pp. 641-643
-
-
Edelman, R.R.1
Manning, W.J.2
Burstein, D.3
Paulin, S.4
-
10
-
-
0028280884
-
Three-dimensional time-of-flight MR angiography using selective inversion recovery RAGE with fat saturation and ECG-triggering: Application to renal arteries
-
D. Li, E. M. Haacke, J. P. Mugler III, S. Berr, J. R. Brookeman, M. C. Hutton. Three-dimensional time-of-flight MR angiography using selective inversion recovery RAGE with fat saturation and ECG-triggering: application to renal arteries. Magn. Reson. Med. 31, 414-422 (1994).
-
(1994)
Magn. Reson. Med.
, vol.31
, pp. 414-422
-
-
Li, D.1
Haacke, E.M.2
Mugler III, J.P.3
Berr, S.4
Brookeman, J.R.5
Hutton, M.C.6
-
11
-
-
0024452121
-
Inversion recovery snapshot FLASH MR imaging
-
A. Haase, D. Matthaei, R. Bartkowski, E. Duhmke, D. Leibfritz, Inversion recovery snapshot FLASH MR imaging. J. Comput. Assist. Tomogr. 13, 1036-1040 (1989).
-
(1989)
J. Comput. Assist. Tomogr.
, vol.13
, pp. 1036-1040
-
-
Haase, A.1
Matthaei, D.2
Bartkowski, R.3
Duhmke, E.4
Leibfritz, D.5
-
12
-
-
0025223702
-
Signal strength in sub-second FLASH magnetic resonance imaging: The dynamic approach to steady state
-
W. Hanicke, K. D. Merboldt, D. Chien, M. L. Gyngell, H. Bruhn, J. Frahm, Signal strength in sub-second FLASH magnetic resonance imaging: the dynamic approach to steady state. Med. Phys. 17, 1004-1010 (1990).
-
(1990)
Med. Phys.
, vol.17
, pp. 1004-1010
-
-
Hanicke, W.1
Merboldt, K.D.2
Chien, D.3
Gyngell, M.L.4
Bruhn, H.5
Frahm, J.6
-
13
-
-
0025679526
-
Approach to equilibrium in snapshot imaging
-
R. A. Jones, P. A. Rinck, Approach to equilibrium in snapshot imaging. Magn. Reson. Imaging 8, 797-803 (1990).
-
(1990)
Magn. Reson. Imaging
, vol.8
, pp. 797-803
-
-
Jones, R.A.1
Rinck, P.A.2
-
14
-
-
45949115591
-
Transverse coherence in rapid FLASH NMR imaging
-
J. Frahm, W. Hanicke, K. D. Merboldt. Transverse coherence in rapid FLASH NMR imaging. J. Magn. Reson. 72, 307-314 (1987).
-
(1987)
J. Magn. Reson.
, vol.72
, pp. 307-314
-
-
Frahm, J.1
Hanicke, W.2
Merboldt, K.D.3
-
15
-
-
0023756028
-
Artifacts due to residual magnetization in three-dimensional magnetic resonance imaging
-
1988
-
M. L. Wood, V. M. Runge, Artifacts due to residual magnetization in three-dimensional magnetic resonance imaging. Med. Phys. 1988; 15, 825-831 (1988).
-
(1988)
Med. Phys.
, vol.15
, pp. 825-831
-
-
Wood, M.L.1
Runge, V.M.2
-
17
-
-
0024987904
-
A spoiling sequence for suppression of residual transverse magnetization
-
H. Z. Wang, S. J. Riederer, A spoiling sequence for suppression of residual transverse magnetization. Magn. Reson. Med. 15, 175-191 (1990).
-
(1990)
Magn. Reson. Med.
, vol.15
, pp. 175-191
-
-
Wang, H.Z.1
Riederer, S.J.2
-
19
-
-
0025985527
-
Spoiling of transverse magnetization in steady-state sequences
-
Y. Zur, M. L. Wood, I. J. Neuringer, Spoiling of transverse magnetization in steady-state sequences. Magn. Reson. Med. 21, 251-263 (1991).
-
(1991)
Magn. Reson. Med.
, vol.21
, pp. 251-263
-
-
Zur, Y.1
Wood, M.L.2
Neuringer, I.J.3
-
20
-
-
0023367344
-
Steady-state magnetizations in rapid NMR imaging using small flip angles and short repetition intervals
-
K. Sekihara, Steady-state magnetizations in rapid NMR imaging using small flip angles and short repetition intervals. IEEE Trans. Med. Imaging MI-6 157-164 (1987).
-
(1987)
IEEE Trans. Med. Imaging
, vol.MI-6
, pp. 157-164
-
-
Sekihara, K.1
-
21
-
-
0023872880
-
An analysis of fast imaging sequences with steady-state transverse magnetization refocusing
-
Y. Zur, S. Stokar, P. Bendel, An analysis of fast imaging sequences with steady-state transverse magnetization refocusing. Magn. Reson. Med. 6, 175-193 (1988).
-
(1988)
Magn. Reson. Med.
, vol.6
, pp. 175-193
-
-
Zur, Y.1
Stokar, S.2
Bendel, P.3
-
22
-
-
0023740116
-
Fast Field Echo Imaging: An Overview and Contrast Calculations
-
P. van der Meulen, J. P. Groen, A. M. C. Tinus, G. Bruntink, Fast Field Echo Imaging: An Overview and Contrast Calculations. Magn. Reson. Imaging 6, 355-368 (1988).
-
(1988)
Magn. Reson. Imaging
, vol.6
, pp. 355-368
-
-
Van Der Meulen, P.1
Groen, J.P.2
Tinus, A.M.C.3
Bruntink, G.4
-
23
-
-
0023705696
-
The application of steady-state free precession in rapid 2DFT NMR imaging: FAST and CE-FAST sequences
-
M. L. Gyngell, The application of steady-state free precession in rapid 2DFT NMR imaging: FAST and CE-FAST sequences. Magn. Reson. Imaging 6, 415-419 (1988).
-
(1988)
Magn. Reson. Imaging
, vol.6
, pp. 415-419
-
-
Gyngell, M.L.1
-
24
-
-
0025123896
-
Fast MR imaging: Techniques and clinical applications
-
E. M. Haacke, J. A. Tkach. Fast MR imaging: techniques and clinical applications. AJR 155, 951-964 (1990).
-
(1990)
AJR
, vol.155
, pp. 951-964
-
-
Haacke, E.M.1
Tkach, J.A.2
-
25
-
-
0025717717
-
Strategies to improve contrast in TurboFLASH imaging: Reordered phase encoding and K-Space segmentation
-
D. Chien, D. J. Atkinson, R. R. Edelman, Strategies to improve contrast in TurboFLASH imaging: reordered phase encoding and K-Space segmentation. J. Magn. Reson. Imaging 1, 63-70 (1991).
-
(1991)
J. Magn. Reson. Imaging
, vol.1
, pp. 63-70
-
-
Chien, D.1
Atkinson, D.J.2
Edelman, R.R.3
-
26
-
-
0028279120
-
Tag contrast in breath-hold CINE cardiac MRI
-
S. B. Reeder, E. R. McVeigh, Tag contrast in breath-hold CINE cardiac MRI. Magn. Reson. Med. 31, 521-525 (1994).
-
(1994)
Magn. Reson. Med.
, vol.31
, pp. 521-525
-
-
Reeder, S.B.1
McVeigh, E.R.2
-
27
-
-
0025942337
-
Magnetization-prepared Rapid Gradient-Echo (MP-RAGE) MR imaging of the liver: Comparison with spin-echo imaging
-
E. E. de Lange, J. P. Mugler III, J. A. Bertolina, et al. Magnetization-prepared Rapid Gradient-Echo (MP-RAGE) MR imaging of the liver: comparison with spin-echo imaging. Magn. Reson. Imaging 9, 469-476 (1991).
-
(1991)
Magn. Reson. Imaging
, vol.9
, pp. 469-476
-
-
De Lange, E.E.1
Mugler III, J.P.2
Bertolina, J.A.3
-
28
-
-
84953656233
-
A review of 1H nuclear magnetic resonance relaxation in pathology: Are T1 and T2 diagnostic?
-
P. A. Bottomley, C. J. Hardy, R. E. Argersinger, G. Allen-Moore, A review of 1H nuclear magnetic resonance relaxation in pathology: are T1 and T2 diagnostic? Med. Phys. 14, 1-37 (1987).
-
(1987)
Med. Phys.
, vol.14
, pp. 1-37
-
-
Bottomley, P.A.1
Hardy, C.J.2
Argersinger, R.E.3
Allen-Moore, G.4
-
29
-
-
0028390778
-
Pulsatile flow artifacts in fast magnetization-prepared sequences
-
T. A. Tasciyan, D. G. Mitchell, Pulsatile flow artifacts in fast magnetization-prepared sequences. J. Magn. Reson. Imaging 4, 217-222 (1994).
-
(1994)
J. Magn. Reson. Imaging
, vol.4
, pp. 217-222
-
-
Tasciyan, T.A.1
Mitchell, D.G.2
-
30
-
-
0027092710
-
Shaping the signal response during the approach to steady state in three-dimensional magnetization-prepared rapid gradient-echo imaging using variable flip angles
-
J. P. Mugler III, F. H. Epstein, J. R. Brookeman, Shaping the signal response during the approach to steady state in three-dimensional magnetization-prepared rapid gradient-echo imaging using variable flip angles. Magn. Reson. Med. 28, 165-185 (1992).
-
(1992)
Magn. Reson. Med.
, vol.28
, pp. 165-185
-
-
Mugler III, J.P.1
Epstein, F.H.2
Brookeman, J.R.3
-
31
-
-
0028247414
-
Improved T1-weighted two-dimensional MP-GRE imaging of the liver with variable flip angles for shaping the signal evolution
-
F. H. Epstein, J. P. Mugler III, J. R. Brookeman, Improved T1-weighted two-dimensional MP-GRE imaging of the liver with variable flip angles for shaping the signal evolution. J. Magn. Reson. Imaging 4, 91-98 (1994).
-
(1994)
J. Magn. Reson. Imaging
, vol.4
, pp. 91-98
-
-
Epstein, F.H.1
Mugler III, J.P.2
Brookeman, J.R.3
|