1
-
-
0026470689
-
Recent trends - A review
-
Vadgama P, Crump PW. Recent trends - a review. Analyst 1992;117:1657-70.
-
(1992)
Analyst
, vol.117
, pp. 1657-1670
-
-
Vadgama, P.1
Crump, P.W.2
-
2
-
-
0027411735
-
In vivo glucose monitoring: Sensor and sensorbility
-
Pickup JC. In vivo glucose monitoring: sensor and sensorbility. Diabetes Care. 1993;16:535-9.
-
(1993)
Diabetes Care.
, vol.16
, pp. 535-539
-
-
Pickup, J.C.1
-
3
-
-
84908830001
-
Can continuous monitoring be used for the treatment of diabetes
-
Reach G, Wilson GS. Can continuous monitoring be used for the treatment of diabetes. Anal Chem. 1992;64:381A-386A
-
(1992)
Anal Chem.
, vol.64
-
-
Reach, G.1
Wilson, G.S.2
-
4
-
-
0026216348
-
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
-
Bindra DS, Zhang Y, Wilson GS, et al. Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring. Anal Chem. 1991;63:1692-6.
-
(1991)
Anal Chem.
, vol.63
, pp. 1692-1696
-
-
Bindra, D.S.1
Zhang, Y.2
Wilson, G.S.3
-
5
-
-
0026546742
-
Towards continuous glucose monitoring: In vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue
-
Moatti-Sirat D, Copron F, Poitout V. et al. Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue. Diabetologia. 1992;35:224-30.
-
(1992)
Diabetologia
, vol.35
, pp. 224-230
-
-
Moatti-Sirat, D.1
Copron, F.2
Poitout, V.3
-
6
-
-
0026628622
-
Amperometric needle-type glucose sensor based on modified platinum electrode with diminished response to interfering materials
-
Chen CY, Gotoh M, Makino H, Su YC, Tamia E, Karube I. Amperometric needle-type glucose sensor based on modified platinum electrode with diminished response to interfering materials. Anal Chim Acta. 1992;265:5-14.
-
(1992)
Anal Chim Acta.
, vol.265
, pp. 5-14
-
-
Chen, C.Y.1
Gotoh, M.2
Makino, H.3
Su, Y.C.4
Tamia, E.5
Karube, I.6
-
7
-
-
0024514006
-
In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and wick method
-
Bruckel J, Kerner W, Zeir H, Steibach G, Pfeiffer EF. In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and wick method. Klin Wochenschr. 1989;67:491-5.
-
(1989)
Klin Wochenschr.
, vol.67
, pp. 491-495
-
-
Bruckel, J.1
Kerner, W.2
Zeir, H.3
Steibach, G.4
Pfeiffer, E.F.5
-
8
-
-
84987589831
-
Effort of interference on amperometric glucose biosensors with cellulose acetate membranes
-
Vaidya R, Wilkins E. Effort of interference on amperometric glucose biosensors with cellulose acetate membranes. Electroanalysis. 1994;6:667-82.
-
(1994)
Electroanalysis
, vol.6
, pp. 667-682
-
-
Vaidya, R.1
Wilkins, E.2
-
9
-
-
10244223555
-
Electrode system for continuous monitoring in cardiovascular surgery
-
Clark LC, Lyons C. Electrode system for continuous monitoring in cardiovascular surgery. Ann NY Acad Sci. 1962;102:29-45.
-
(1962)
Ann NY Acad Sci.
, vol.102
, pp. 29-45
-
-
Clark, L.C.1
Lyons, C.2
-
10
-
-
0020037171
-
Progress toward a potentially implantable, enzyme-based glucose sensor
-
Clark LC, Duggon C. Progress toward a potentially implantable, enzyme-based glucose sensor. Diabetes Care. 1982;5:190-8.
-
(1982)
Diabetes Care.
, vol.5
, pp. 190-198
-
-
Clark, L.C.1
Duggon, C.2
-
11
-
-
0023346438
-
Long term in vitro operation of enzyme electrode based glucose sensor
-
Conway PJ, Gough DA. Long term in vitro operation of enzyme electrode based glucose sensor. Sensors & Actuators. 1987;11:305-8.
-
(1987)
Sensors & Actuators.
, vol.11
, pp. 305-308
-
-
Conway, P.J.1
Gough, D.A.2
-
13
-
-
0025689061
-
Application of chronic intravascular blood glucose sensor in dogs
-
Armor JC, Lucisano JY, McKean BD, Gough DA. Application of chronic intravascular blood glucose sensor in dogs. Diabetes. 1990;39:1519-26.
-
(1990)
Diabetes
, vol.39
, pp. 1519-1526
-
-
Armor, J.C.1
Lucisano, J.Y.2
McKean, B.D.3
Gough, D.A.4
-
14
-
-
84973003408
-
Glucose biosensor based on oxygen electrode. Part I: Silastic coated polycarbonate membrane for biosensor application
-
Atanasov P, Wilkins E. Glucose biosensor based on oxygen electrode. Part I: silastic coated polycarbonate membrane for biosensor application. Analytical Letters. 1993;28:1587-612.
-
(1993)
Analytical Letters
, vol.28
, pp. 1587-1612
-
-
Atanasov, P.1
Wilkins, E.2
-
15
-
-
0043230063
-
Glucose biosensor on oxygen electrode. Part II: Long term operational stability of the rechargeable glucose biosensor
-
Atanasov P, Wilkins E. Glucose biosensor on oxygen electrode. Part II: long term operational stability of the rechargeable glucose biosensor. Analytical Letters. 1993;26:2079-94.
-
(1993)
Analytical Letters
, vol.26
, pp. 2079-2094
-
-
Atanasov, P.1
Wilkins, E.2
|