메뉴 건너뛰기




Volumn 322, Issue , 1996, Pages 166-173

Biodegradable pin fixation of osteochondral fragments of the knee

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BIODEGRADATION; CHILD; CLINICAL ARTICLE; FEMALE; FOLLOW UP; HUMAN; IMPLANTATION; MALE; OSTEOCHONDRITIS DISSECANS; PATELLA FRACTURE; PRIORITY JOURNAL; RETROSPECTIVE STUDY; TREATMENT OUTCOME;

EID: 0030044711     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1097/00003086-199601000-00021     Document Type: Article
Times cited : (124)

References (26)
  • 1
    • 0015109836 scopus 로고
    • Osteochondritis dissecans of the knee. A clinical study
    • Aichroth P: Osteochondritis dissecans of the knee. A clinical study. J Bone Joint Surg 53B:440-447, 1971.
    • (1971) J Bone Joint Surg , vol.53 B , pp. 440-447
    • Aichroth, P.1
  • 2
    • 84925554283 scopus 로고
    • Zur Therapie der Osteochondritis Dissecans
    • Bandi W, Allgöwer M: Zur Therapie der Osteochondritis Dissecans. Helv Chir Acta 26:552-560, 1959.
    • (1959) Helv Chir Acta , vol.26 , pp. 552-560
    • Bandi, W.1    Allgöwer, M.2
  • 3
    • 0027052802 scopus 로고
    • Synovitis of the knee after intraarticular fracture fixation with Biofix®. Report of two cases
    • Barford G, Svendsen RN: Synovitis of the knee after intraarticular fracture fixation with Biofix®. Report of two cases. Acta Orthop Scand 63:680-681, 1992.
    • (1992) Acta Orthop Scand , vol.63 , pp. 680-681
    • Barford, G.1    Svendsen, R.N.2
  • 4
    • 0027308691 scopus 로고
    • Foreign body reactions to resorbable poly(L-lactide) bone plates and screws used for the fixation of unstable zygomatic fractures
    • Bergsma EJ, Rozema FR, Bos RR, de Bruijin WC: Foreign body reactions to resorbable poly(L-lactide) bone plates and screws used for the fixation of unstable zygomatic fractures. J Oral Maxillofac Surg 51:666-670, 1993.
    • (1993) J Oral Maxillofac Surg , vol.51 , pp. 666-670
    • Bergsma, E.J.1    Rozema, F.R.2    Bos, R.R.3    De Bruijin, W.C.4
  • 5
    • 0025334647 scopus 로고
    • Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers
    • Böstman O: Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg 72B:592-596, 1990.
    • (1990) J Bone Joint Surg , vol.72 B , pp. 592-596
    • Böstman, O.1
  • 6
    • 0025784686 scopus 로고
    • Osteolytic changes accompanying degradation of absorbable fracture fixation implants
    • Böstman O: Osteolytic changes accompanying degradation of absorbable fracture fixation implants. J Bone Joint Surg 73B:679-682, 1991.
    • (1991) J Bone Joint Surg , vol.73 B , pp. 679-682
    • Böstman, O.1
  • 7
    • 0025971712 scopus 로고
    • Current concepts review. Absorbable implants for the fixation of fractures
    • Böstman O: Current concepts review. Absorbable implants for the fixation of fractures. J Bone Joint Surg 73A:148-153, 1991.
    • (1991) J Bone Joint Surg , vol.73 A , pp. 148-153
    • Böstman, O.1
  • 8
    • 0028316813 scopus 로고
    • Fixation with bioabsorbable screws for the treatment of fractures of the ankle
    • Bucholz RW, Henry S, Henly B: Fixation with bioabsorbable screws for the treatment of fractures of the ankle. J Bone Joint Surg 76A:319-324, 1994.
    • (1994) J Bone Joint Surg , vol.76 A , pp. 319-324
    • Bucholz, R.W.1    Henry, S.2    Henly, B.3
  • 9
    • 0022593256 scopus 로고
    • Resorbierbare Implantate zur Refixierung von osteochondralen Fragmenten in Gelenkflachen
    • Cales H, Burri C, Kiefer H, Mutschler W: Resorbierbare Implantate zur Refixierung von osteochondralen Fragmenten in Gelenkflachen. Aktuel Traumatol 16:74-77, 1986.
    • (1986) Aktuel Traumatol , vol.16 , pp. 74-77
    • Cales, H.1    Burri, C.2    Kiefer, H.3    Mutschler, W.4
  • 10
    • 0025389116 scopus 로고
    • Mechanical properties of biodegradable polymers and composites proposed for internal fixation of bone
    • Daniel AU, Chang MKO, Andriano KP: Mechanical properties of biodegradable polymers and composites proposed for internal fixation of bone. J Appl Biomater 1:57-78, 1990.
    • (1990) J Appl Biomater , vol.1 , pp. 57-78
    • Daniel, A.U.1    Chang, M.K.O.2    Andriano, K.P.3
  • 11
    • 0026513175 scopus 로고
    • Severe synovitis of the knee after biodegradable internal fixation. A case report
    • Fridén T, Rydholm U: Severe synovitis of the knee after biodegradable internal fixation. A case report. Acta Orthop Scand 63:94-97, 1992.
    • (1992) Acta Orthop Scand , vol.63 , pp. 94-97
    • Fridén, T.1    Rydholm, U.2
  • 12
    • 0021988052 scopus 로고
    • Tierexperimentelle Untersuchungen zur Anwendung von absorbierbaren Osteosyntheseschrauben aus Polydioxanon (PDS)
    • Gay B, Bucher H: Tierexperimentelle Untersuchungen zur Anwendung von absorbierbaren Osteosyntheseschrauben aus Polydioxanon (PDS). Unfallchirurg 88:126-133, 1985.
    • (1985) Unfallchirurg , vol.88 , pp. 126-133
    • Gay, B.1    Bucher, H.2
  • 13
    • 0029120601 scopus 로고
    • Tissue reaction of biodegradable ultra high strength poly (l-lactide) rod: A long term study in rabbits
    • Matsusue Y, Hanafusa S, Yamamuro T, et al: Tissue reaction of biodegradable ultra high strength poly (l-lactide) rod: A long term study in rabbits. Clin Orthop 317: 246-253, 1995.
    • (1995) Clin Orthop , vol.317 , pp. 246-253
    • Matsusue, Y.1    Hanafusa, S.2    Yamamuro, T.3
  • 14
    • 0026996669 scopus 로고
    • In vitro and in vivo studies on bioabsorbable ultra-high-strength poly(L-lactide) rods
    • Matsusue Y, Yamamuro T, Oka M, et al: In vitro and in vivo studies on bioabsorbable ultra-high-strength poly(L-lactide) rods. J Biomed Mater Res 26: 1553-1567, 1992.
    • (1992) J Biomed Mater Res , vol.26 , pp. 1553-1567
    • Matsusue, Y.1    Yamamuro, T.2    Oka, M.3
  • 15
    • 0024364503 scopus 로고
    • Resurfacing of the knee with fresh osteochondral allograft
    • Meyers MH, Akeson W, Convery R: Resurfacing of the knee with fresh osteochondral allograft. J Bone Joint Surg 71A:704-713, 1989.
    • (1989) J Bone Joint Surg , vol.71 A , pp. 704-713
    • Meyers, M.H.1    Akeson, W.2    Convery, R.3
  • 16
    • 0027217152 scopus 로고
    • Polylactide screw in acetabular osteotomy. 28 dysplastic hips followed for 1 year
    • Nakamura S, Ninomiya S, Takatori Y, et al: Polylactide screw in acetabular osteotomy. 28 dysplastic hips followed for 1 year. Acta Orthop Scand 64:301-302, 1993.
    • (1993) Acta Orthop Scand , vol.64 , pp. 301-302
    • Nakamura, S.1    Ninomiya, S.2    Takatori, Y.3
  • 17
    • 0026458592 scopus 로고
    • Absorbable pins of self-reinforced poly-L-lactic acid for fixation of fractures and osteotomies
    • Pihlajamäki H, Böstman O, Hirvensalo E, Törmälä P, Rokkanen P: Absorbable pins of self-reinforced poly-L-lactic acid for fixation of fractures and osteotomies. J Bone Joint Surg 74B:853-857, 1992.
    • (1992) J Bone Joint Surg , vol.74 B , pp. 853-857
    • Pihlajamäki, H.1    Böstman, O.2    Hirvensalo, E.3    Törmälä, P.4    Rokkanen, P.5
  • 18
    • 0021842535 scopus 로고
    • Biodegradable implants in fracture fixation: Early results of treatment of fractures of the ankle
    • Rokkanen P, Böstman O, Vainionpää S, et al: Biodegradable implants in fracture fixation: Early results of treatment of fractures of the ankle. Lancet 1:1422-1424, 1985.
    • (1985) Lancet , vol.1 , pp. 1422-1424
    • Rokkanen, P.1    Böstman, O.2    Vainionpää, S.3
  • 19
    • 0026326678 scopus 로고
    • Tibial cortical bone peg fixation in osteochondritis dissecans of the knee
    • Slough JA, Noto AM, Schmidt TL: Tibial cortical bone peg fixation in osteochondritis dissecans of the knee. Clin Orthop 267:122-127, 1991.
    • (1991) Clin Orthop , vol.267 , pp. 122-127
    • Slough, J.A.1    Noto, A.M.2    Schmidt, T.L.3
  • 20
    • 0001045037 scopus 로고
    • Treatment of osteochondritis dissecans
    • Smillie IS: Treatment of osteochondritis dissecans. J Bone Joint Surg 39B:248-260, 1957.
    • (1957) J Bone Joint Surg , vol.39 B , pp. 248-260
    • Smillie, I.S.1
  • 21
    • 0028117108 scopus 로고
    • Activation of complement system and adverse effects of biodegradable pins of polylactic acid (Biofix®) in osteochondritis dissecans
    • Tegnander A, Engebretsen L, Bergh K, et al: Activation of complement system and adverse effects of biodegradable pins of polylactic acid (Biofix®) in osteochondritis dissecans. Acta Orthop Scand 65:472-475, 1994.
    • (1994) Acta Orthop Scand , vol.65 , pp. 472-475
    • Tegnander, A.1    Engebretsen, L.2    Bergh, K.3
  • 22
    • 0041387259 scopus 로고
    • Osteochondritis dissecans: Fixation with Ethipins
    • 4th Quarter
    • Thomas W, Lutten C, Lorenz H: Osteochondritis dissecans: Fixation with Ethipins. Ethicon Op Forum 132, 4th Quarter, 1987.
    • (1987) Ethicon Op Forum , vol.132
    • Thomas, W.1    Lutten, C.2    Lorenz, H.3
  • 23
    • 0023519533 scopus 로고
    • Osteochondritis dissecans and osteochondral fragments managed by Herbert compression screw fixation
    • Thomson NL: Osteochondritis dissecans and osteochondral fragments managed by Herbert compression screw fixation. Clin Orthop 224:71-78, 1987.
    • (1987) Clin Orthop , vol.224 , pp. 71-78
    • Thomson, N.L.1
  • 24
    • 0025961327 scopus 로고
    • Ultrahigh-strength absorbable self-reinforced polyglycolide (SR-PGA) composite rods for internal fixation of bone fractures: In vitro and in vivo study
    • Törmälä P, Vasenius J, Vanionpää S, et al: Ultrahigh-strength absorbable self-reinforced polyglycolide (SR-PGA) composite rods for internal fixation of bone fractures: In vitro and in vivo study. J Biomed Mater Res 25:1-22, 1991.
    • (1991) J Biomed Mater Res , vol.25 , pp. 1-22
    • Törmälä, P.1    Vasenius, J.2    Vanionpää, S.3
  • 25
    • 0028593351 scopus 로고
    • A clinical study on bioabsorbable osteosynthetic implants made of ultra-high-strength poly-1-lactide
    • Yamamuro T, Matsusue Y, Uchida A, et al: A clinical study on bioabsorbable osteosynthetic implants made of ultra-high-strength poly-1-lactide. Int Orthop (SICOT) 18:332-340, 1994.
    • (1994) Int Orthop (SICOT) , vol.18 , pp. 332-340
    • Yamamuro, T.1    Matsusue, Y.2    Uchida, A.3
  • 26
    • 0022294844 scopus 로고
    • Autogeneic osteochondral fragment for osteochondritis dissecans of the knee
    • Yamashita F, Sakakida K, Suzu F, et al: Autogeneic osteochondral fragment for osteochondritis dissecans of the knee. Clin Orthop 201:43-50, 1985.
    • (1985) Clin Orthop , vol.201 , pp. 43-50
    • Yamashita, F.1    Sakakida, K.2    Suzu, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.