Volumn 155, Issue 2, 1996, Pages 686-688

Ventriculoperitoneal shunt infection after augmentation cystoplasty

Author keywords

bladder; infection

Indexed keywords

ARTICLE; BLADDER CAPACITY; BLADDER RECONSTRUCTION; BRAIN VENTRICLE PERITONEUM SHUNT; CHILD; CLINICAL ARTICLE; FEMALE; HUMAN; INFECTION RISK; MALE; MYELODYSPLASIA; NEUROGENIC BLADDER; POSTOPERATIVE INFECTION; PRIORITY JOURNAL;

EID: 0030040678     PISSN: 00225347     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0022-5347(01)66500-5     Document Type: Article
Times cited : (22)

References (9)
  • 4
    • 0021750216 scopus 로고
    • CSF shunt infections in pediatrics. A seven-year experience
    • Odio, C., McCracken, G. H., Jr. and Nelson, J. D.: CSF shunt infections in pediatrics. A seven-year experience. Amer. J. Dis. Child., 138: 1103, 1984.
    • (1984) Amer. J. Dis. Child. , vol.138 , pp. 1103
    • Odio, C.1    McCracken Jr., G.H.2    Nelson, J.D.3
  • 5
    • 0025173062 scopus 로고
    • Augmentation cystoplasty complicated by postoperative ventriculoperitoneal shunt infection
    • Kreder, K. J., Webster, G. D. and Oakes, W. J.: Augmentation cystoplasty complicated by postoperative ventriculoperitoneal shunt infection. J. Urol., 144: 955, 1990.
    • (1990) J. Urol. , vol.144 , pp. 955
    • Kreder, K.J.1    Webster, G.D.2    Oakes, W.J.3
  • 6
    • 0026210290 scopus 로고
    • Abdominal cerebrospinal fluid pseudocyst: Occurrence after intraperitoneal urologic surgery in children with ventriculoperitoneal shunts
    • White, B., Kropp, K. and Rayport, M.: Abdominal cerebrospinal fluid pseudocyst: occurrence after intraperitoneal urologic surgery in children with ventriculoperitoneal shunts. J. Urol., 146: 583, 1991.
    • (1991) J. Urol. , vol.146 , pp. 583
    • White, B.1    Kropp, K.2    Rayport, M.3
  • 7
    • 0020508265 scopus 로고
    • Cerebrospinal fluid shunt infections. A review of 35 infections in 32 patients
    • Forward, K. R., Fewer, H. D. and Stiver, H. G.: Cerebrospinal fluid shunt infections. A review of 35 infections in 32 patients. J. Neurosurg., 59: 389, 1983.
    • (1983) J. Neurosurg. , vol.59 , pp. 389
    • Forward, K.R.1    Fewer, H.D.2    Stiver, H.G.3
  • 8
    • 0027771075 scopus 로고
    • Practical measures to control device-related bacterial infections
    • Costerton, J. W., Khoury, A. E., Ward, K. H. and Anwar, H.: Practical measures to control device-related bacterial infections. Int. J. Artif. Organs, 16: 765, 1993.
    • (1993) Int. J. Artif. Organs , vol.16 , pp. 765
    • Costerton, J.W.1    Khoury, A.E.2    Ward, K.H.3    Anwar, H.4
  • 9
    • 0026539761 scopus 로고
    • Prevention and control of bacterial infections associated with medical devices
    • Khoury, A. E., Lam, K., Ellis, B. and Costerton, J. W.: Prevention and control of bacterial infections associated with medical devices. ASAIO J., 38: m174, 1992.
    • (1992) ASAIO J. , vol.38
    • Khoury, A.E.1    Lam, K.2    Ellis, B.3    Costerton, J.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.