Dual-energy x-ray bone densitometer incorporating an internal reference system
-
Stein JA, Lazewatsky JL, Hochberg AM (1987) Dual-energy x-ray bone densitometer incorporating an internal reference system. Radiology 165(suppl):313
-
(1987)
Radiology
, vol.165
, Issue.SUPPL.
, pp. 313
-
-
Stein, J.A.1
Lazewatsky, J.L.2
Hochberg, A.M.3
-
2
-
-
0023727897
-
Comparison of dual-energy x-ray absorptiometry and dual photon absorptiometry for bone mineral measurements of the lumbar spine
-
Wahner HW, Dunn WL, Brown ML, Morin RL, Riggs BL (1988) Comparison of dual-energy x-ray absorptiometry and dual photon absorptiometry for bone mineral measurements of the lumbar spine. Mayo Clin Proc 63:1075-1084
-
(1988)
Mayo Clin Proc
, vol.63
, pp. 1075-1084
-
-
Wahner, H.W.1
Dunn, W.L.2
Brown, M.L.3
Morin, R.L.4
Riggs, B.L.5
-
3
-
-
0026034394
-
Longitudinal precision of dual-energy x-ray absorptiometry in a multicenter study
-
Orwoll ES, Oviatt SK (1991) Longitudinal precision of dual-energy x-ray absorptiometry in a multicenter study. J Bone Miner Res 6:191-197
-
(1991)
J Bone Miner Res
, vol.6
, pp. 191-197
-
-
Orwoll, E.S.1
Oviatt, S.K.2
-
5
-
-
0027214638
-
Quality assurance for bone densitometry research studies: Concept and impact
-
Glüer C-C, Faulkner KG, Estilo MJ, Engelke K, Rosin J, Genant HK (1993) Quality assurance for bone densitometry research studies: concept and impact. Osteoporosis Int 3:227-235
-
(1993)
Osteoporosis Int
, vol.3
, pp. 227-235
-
-
Glüer, C.-C.1
Faulkner, K.G.2
Estilo, M.J.3
Engelke, K.4
Rosin, J.5
Genant, H.K.6
-
6
-
-
0028991317
-
Quality control of DXA instruments in multicentre trials
-
Faulkner KG, McClung MR (1995) Quality control of DXA instruments in multicentre trials. Osteoporosis Int 5:218-227
-
(1995)
Osteoporosis Int
, vol.5
, pp. 218-227
-
-
Faulkner, K.G.1
McClung, M.R.2
-
7
-
-
0027529964
-
Bone density at various sites for prediction of hip fractures
-
Cummings SR, Black DM, Nevitt MC, Browner W, Cauley J, Ensrud K, Genant HK, Palermo L, Scott J, Vogt TM (1993) Bone density at various sites for prediction of hip fractures. Lancet 341:72-75
-
(1993)
Lancet
, vol.341
, pp. 72-75
-
-
Cummings, S.R.1
Black, D.M.2
Nevitt, M.C.3
Browner, W.4
Cauley, J.5
Ensrud, K.6
Genant, H.K.7
Palermo, L.8
Scott, J.9
Vogt, T.M.10
-
8
-
-
0026046427
-
Comparative performance in vitro and in vivo of Lunar DPX and Hologic QDR-1000 dual energy x-ray absorptiometers
-
Laskey MA, Flaxman ME, Barber RW, Trafford S, Hayball MP, Lyttle KD, Crisp AJ, Compston JE (1991) Comparative performance in vitro and in vivo of Lunar DPX and Hologic QDR-1000 dual energy x-ray absorptiometers. Br J Radiol 64:1023-1029
-
(1991)
Br J Radiol
, vol.64
, pp. 1023-1029
-
-
Laskey, M.A.1
Flaxman, M.E.2
Barber, R.W.3
Trafford, S.4
Hayball, M.P.5
Lyttle, K.D.6
Crisp, A.J.7
Compston, J.E.8
-
9
-
-
0027532266
-
Cross-calibration of DXA equipment: Upgrading from a Hologic QDR-1000/W to a QDR-2000
-
Faulkner KG, Glüer C-C, Estilo M, Genant HK (1993) Cross-calibration of DXA equipment: upgrading from a Hologic QDR-1000/W to a QDR-2000. Calcif Tissue Int 52:79-84
-
(1993)
Calcif Tissue Int
, vol.52
, pp. 79-84
-
-
Faulkner, K.G.1
Glüer, C.-C.2
Estilo, M.3
Genant, H.K.4
-
10
-
-
0024398028
-
Calibration and standardization of bone mineral densitometers
-
Kelly TL, Slovik DM, Neer RM (1989) Calibration and standardization of bone mineral densitometers. J Bone Miner Res 4:663-669
-
(1989)
J Bone Miner Res
, vol.4
, pp. 663-669
-
-
Kelly, T.L.1
Slovik, D.M.2
Neer, R.M.3
-
11
-
-
0027504762
-
Dual x-ray absorptiometry: A comparison between fan beam and pencil beam scans
-
Blake GM, Parker JC, Buxton FMA, Fogelman I (1993) Dual x-ray absorptiometry: a comparison between fan beam and pencil beam scans. Br J Radiol 66:902-906
-
(1993)
Br J Radiol
, vol.66
, pp. 902-906
-
-
Blake, G.M.1
Parker, J.C.2
Buxton, F.M.A.3
Fogelman, I.4
-
12
-
-
0029080928
-
The European Spine Phantom - A tool for standardization and quality control in spinal bone mineral measurements by DXA and QCT
-
Kalender WA, Felsenberg D, Genant HK, Fischer M, Dequeker J, Reeve J (1995) The European Spine Phantom - a tool for standardization and quality control in spinal bone mineral measurements by DXA and QCT. Eur J Radiol 20: 83-92
-
(1995)
Eur J Radiol
, vol.20
, pp. 83-92
-
-
Kalender, W.A.1
Felsenberg, D.2
Genant, H.K.3
Fischer, M.4
Dequeker, J.5
Reeve, J.6
-
13
-
-
0027967093
-
Universal standardization for dual x-ray absorptiometry: Patient and phantom cross-calibration
-
Genant HK, Grampp S, Glüer C-C, Faulkner KG, Jergas M, Engelke K, Hagiwara S, van Kuijk C (1994) Universal standardization for dual x-ray absorptiometry: patient and phantom cross-calibration. J Bone Miner Res 9:1503-1514
-
(1994)
J Bone Miner Res
, vol.9
, pp. 1503-1514
-
-
Genant, H.K.1
Grampp, S.2
Glüer, C.-C.3
Faulkner, K.G.4
Jergas, M.5
Engelke, K.6
Hagiwara, S.7
Van Kuijk, C.8
-
14
-
-
8944256153
-
Upgrading dual energy x-ray absortiometry scanners: Do new models provide equivalent results?
-
Harper KD, Lobaugh B, King ST, Drezner MK (1992) Upgrading dual energy x-ray absortiometry scanners: Do new models provide equivalent results? J Bone Miner Res 7(suppl):S191
-
(1992)
J Bone Miner Res
, vol.7
, Issue.SUPPL.
-
-
Harper, K.D.1
Lobaugh, B.2
King, S.T.3
Drezner, M.K.4
-
15
-
-
0028077289
-
Switching from DXA pencil-beam to fan beam. I: Studies in vitro in four centers
-
Eiken P, Bärenholdt O, Bjorn Jensen L, Gram J, Pors Nielsen S (1994) Switching from DXA pencil-beam to fan beam. I: studies in vitro in four centers. Bone 15:667-670
-
(1994)
Bone
, vol.15
, pp. 667-670
-
-
Eiken, P.1
Bärenholdt, O.2
Bjorn Jensen, L.3
Gram, J.4
Pors Nielsen, S.5
-
16
-
-
0028043666
-
Switching from DXA pencil-beam to fan-beam. II: Studies in vivo
-
Eiken P, Kolthoff N, Bärenholdt O, Hermansen F, Pors Nielsen S (1994) Switching from DXA pencil-beam to fan-beam. II: studies in vivo. Bone 15:671-676
-
(1994)
Bone
, vol.15
, pp. 671-676
-
-
Eiken, P.1
Kolthoff, N.2
Bärenholdt, O.3
Hermansen, F.4
Pors Nielsen, S.5
-
17
-
-
0028051591
-
Comparison of four methods for cross-calibrating dual-energy x-ray absorptiometers to eliminate systematic errors when upgrading equipment
-
Finkelstein JS, Butler JP, Cleary RL, Neer RM (1994) Comparison of four methods for cross-calibrating dual-energy x-ray absorptiometers to eliminate systematic errors when upgrading equipment. J Bone Miner Res 9:1945-1952
-
(1994)
J Bone Miner Res
, vol.9
, pp. 1945-1952
-
-
Finkelstein, J.S.1
Butler, J.P.2
Cleary, R.L.3
Neer, R.M.4
-
18
-
-
3342912747
-
Replacing dual x-ray absorptiometry scanners: Cross-calibration of a new multidetector array system
-
Blake GM, Fogelman I (1995) Replacing dual x-ray absorptiometry scanners: cross-calibration of a new multidetector array system. J Bone Miner Res 10(suppl):S267
-
(1995)
J Bone Miner Res
, vol.10
, Issue.SUPPL.
-
-
Blake, G.M.1
Fogelman, I.2
-
19
-
-
8944220303
-
Comparison of bone mineral density measurement between the Hologic QDR2000 and the QDR4500A
-
Prince R, Price R, Gutteridge D, Retallack R, Dick I, Lemmon J, Hall S, LeDain S (1995) Comparison of bone mineral density measurement between the Hologic QDR2000 and the QDR4500A. J Bone Miner Res 10(suppl):S272
-
(1995)
J Bone Miner Res
, vol.10
, Issue.SUPPL.
-
-
Prince, R.1
Price, R.2
Gutteridge, D.3
Retallack, R.4
Dick, I.5
Lemmon, J.6
Hall, S.7
Ledain, S.8
-
20
-
-
0001584034
-
Performance evaluation of a new bone densitometer: Hologic QDR-4500
-
Fuerst T, Glüer C-C, Genant HK (1995) Performance evaluation of a new bone densitometer: Hologic QDR-4500. J Bone Miner Res 10(suppl):S370
-
(1995)
J Bone Miner Res
, vol.10
, Issue.SUPPL.
-
-
Fuerst, T.1
Glüer, C.-C.2
Genant, H.K.3
-
21
-
-
0001955555
-
Standards for body composition calibration in DEXA
-
Ring EFJ (ed) British Institute of Radiology, London
-
Nord RH, Payne RK (1990) Standards for body composition calibration in DEXA. In: Ring EFJ (ed) Current research in osteoporosis and bone mineral measurement. British Institute of Radiology, London, pp 27-28
-
(1990)
Current Research in Osteoporosis and Bone Mineral Measurement
, pp. 27-28
-
-
Nord, R.H.1
Payne, R.K.2
|