메뉴 건너뛰기




Volumn 42, Issue 1, 1996, Pages 140-145

Current status and performance goals for serum thyrotropin (TSH) assays

Author keywords

functional sensitivity; immunoassays

Indexed keywords

THYROTROPIN;

EID: 0030034886     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1093/clinchem/42.1.140     Document Type: Conference Paper
Times cited : (163)

References (40)
  • 1
    • 0015042669 scopus 로고
    • Utility of the radioimmunoassay of serum thyrotropin in man
    • Hershman J. Utility of the radioimmunoassay of serum thyrotropin in man. Ann Intern Med 1971;74:481-90.
    • (1971) Ann Intern Med , vol.74 , pp. 481-490
    • Hershman, J.1
  • 4
    • 0028938960 scopus 로고
    • Interlaboratory/intermethod differences in functional sensitivity of immunometric assays for thyrotropin (TSH): Impact on reliability of measurement of subnormal concentration
    • Spencer CA, Takeuchi M, Kazarosyn M, MacKenzie F, Beckett GJ, Wilkinson E. Interlaboratory/intermethod differences in functional sensitivity of immunometric assays for thyrotropin (TSH): impact on reliability of measurement of subnormal concentration. Clin Chem 1995;41:367-74.
    • (1995) Clin Chem , vol.41 , pp. 367-374
    • Spencer, C.A.1    Takeuchi, M.2    Kazarosyn, M.3    MacKenzie, F.4    Beckett, G.J.5    Wilkinson, E.6
  • 6
    • 0018127669 scopus 로고
    • Statistical estimation of the minimal detectable concentration ("sensitivity") for radioligand assays
    • Rodbard D. Statistical estimation of the minimal detectable concentration ("sensitivity") for radioligand assays. Anal Biochem 1978;90:1-12.
    • (1978) Anal Biochem , vol.90 , pp. 1-12
    • Rodbard, D.1
  • 7
    • 0026355888 scopus 로고
    • American Thyroid Association assessment of current free thyroid hormone and thyrotropin measurements and guidelines for future clinical assays
    • Hay ID, Bayer MF, Kaplan MM, Klee GG, Larsen PR, Spencer CA. American Thyroid Association assessment of current free thyroid hormone and thyrotropin measurements and guidelines for future clinical assays. Clin Chem 1991;37:2002-8.
    • (1991) Clin Chem , vol.37 , pp. 2002-2008
    • Hay, I.D.1    Bayer, M.F.2    Kaplan, M.M.3    Klee, G.G.4    Larsen, P.R.5    Spencer, C.A.6
  • 8
    • 0024413529 scopus 로고
    • 4 estimate or sensitive TSH measurement
    • 4 estimate or sensitive TSH measurement. J Clin Immunoassay 1989;12:82-9.
    • (1989) J Clin Immunoassay , vol.12 , pp. 82-89
    • Spencer, C.A.1
  • 9
    • 0025039753 scopus 로고
    • The use and misuse of the sensitive thyrotropin assays
    • Nicoloff JT, Spencer CA. The use and misuse of the sensitive thyrotropin assays. J Clin Endocrinol Metab 1990;71:553-8.
    • (1990) J Clin Endocrinol Metab , vol.71 , pp. 553-558
    • Nicoloff, J.T.1    Spencer, C.A.2
  • 10
    • 0027226126 scopus 로고
    • Desirable standards for laboratory tests if they are to fulfill medical needs
    • Fraser CG, Petersen PH. Desirable standards for laboratory tests if they are to fulfill medical needs. Clin Chem 1993;39:1447-55.
    • (1993) Clin Chem , vol.39 , pp. 1447-1455
    • Fraser, C.G.1    Petersen, P.H.2
  • 13
    • 0023611627 scopus 로고
    • Specificity of sensitive assays of thyrotropin (TSH) used to screen for thyroid disease in hospitalized patients
    • Spencer CA, Eigen A, Shen D, Duda M, Qualls S, Weiss S, et al. Specificity of sensitive assays of thyrotropin (TSH) used to screen for thyroid disease in hospitalized patients. Clin Chem 1987;33: 1391-6.
    • (1987) Clin Chem , vol.33 , pp. 1391-1396
    • Spencer, C.A.1    Eigen, A.2    Shen, D.3    Duda, M.4    Qualls, S.5    Weiss, S.6
  • 14
    • 0021821086 scopus 로고
    • The Second International Reference Preparation of thyroid-stimulating hormone, for immunoassay: Calibration by bioassay and immunoassay in an international collaborative study
    • Gaines Das RE, Bristow AF. The Second International Reference Preparation of thyroid-stimulating hormone, for immunoassay: calibration by bioassay and immunoassay in an international collaborative study. J Endocrinol 1985;104:367-79.
    • (1985) J Endocrinol , vol.104 , pp. 367-379
    • Gaines Das, R.E.1    Bristow, A.F.2
  • 15
    • 0027358990 scopus 로고
    • Chemiluminescent third-generation assay (Amerlite TSH-30) of thyroid-stimulating hormone in serum or plasma assessed
    • Wilkinson E, Rae P, Thomson K, Toft A, Spencer C, Beckett G. Chemiluminescent third-generation assay (Amerlite TSH-30) of thyroid-stimulating hormone in serum or plasma assessed. Clin Chem 1993;39:2166-73.
    • (1993) Clin Chem , vol.39 , pp. 2166-2173
    • Wilkinson, E.1    Rae, P.2    Thomson, K.3    Toft, A.4    Spencer, C.5    Beckett, G.6
  • 16
    • 0023853204 scopus 로고
    • Heterophilic antibodies: A problem for all immunoassays
    • Boscato LM, Stuart MC. Heterophilic antibodies: a problem for all immunoassays. Clin Chem 1988;34:27-33.
    • (1988) Clin Chem , vol.34 , pp. 27-33
    • Boscato, L.M.1    Stuart, M.C.2
  • 17
    • 0027729353 scopus 로고
    • Persistent problems with the specificity of immunometric TSH assays
    • Laurberg P. Persistent problems with the specificity of immunometric TSH assays. Thyroid 1993;4:279-83.
    • (1993) Thyroid , vol.4 , pp. 279-283
    • Laurberg, P.1
  • 19
    • 0014412939 scopus 로고
    • Labeled antibodies and immunological assay systems
    • Miles LEM, Hales CN. Labeled antibodies and immunological assay systems. Nature 1968;219:186-9.
    • (1968) Nature , vol.219 , pp. 186-189
    • Miles, L.E.M.1    Hales, C.N.2
  • 20
    • 0028066746 scopus 로고
    • Ability of two new thyrotropin (TSH) assays to separate hyperthyroid patients from euthyroid patients with low TSH
    • Taimela E, Tahtela R, Koskinen P, Nuutila P, Forsstrom J, Taimela S, et al. Ability of two new thyrotropin (TSH) assays to separate hyperthyroid patients from euthyroid patients with low TSH. Clin Chem 1994;40:101-5.
    • (1994) Clin Chem , vol.40 , pp. 101-105
    • Taimela, E.1    Tahtela, R.2    Koskinen, P.3    Nuutila, P.4    Forsstrom, J.5    Taimela, S.6
  • 21
    • 0015946571 scopus 로고
    • The immunoradiometric assay and related techniques
    • Woodhead JS, Addison GM, Hales CN. The immunoradiometric assay and related techniques. Br Med Bull 1974;30:44-9.
    • (1974) Br Med Bull , vol.30 , pp. 44-49
    • Woodhead, J.S.1    Addison, G.M.2    Hales, C.N.3
  • 22
    • 0021711514 scopus 로고
    • A sensitive immunoradiometric assay for serum thyroid stimulating hormone: A replacement for the thyrotropin releasing test
    • Seth JH, Caldwell G, Sweeting VM, Beckett GJ, Gow SM, Toft AD. A sensitive immunoradiometric assay for serum thyroid stimulating hormone: a replacement for the thyrotropin releasing test. Br Med J 1984;289:1334-6.
    • (1984) Br Med J , vol.289 , pp. 1334-1336
    • Seth, J.H.1    Caldwell, G.2    Sweeting, V.M.3    Beckett, G.J.4    Gow, S.M.5    Toft, A.D.6
  • 23
    • 0022579321 scopus 로고
    • Chemiluminescence immunoassay: An overview
    • Weeks I, Sturgess ML, Woodhead JS. Chemiluminescence immunoassay: an overview. Clin Sci 1986;70:403-8.
    • (1986) Clin Sci , vol.70 , pp. 403-408
    • Weeks, I.1    Sturgess, M.L.2    Woodhead, J.S.3
  • 26
    • 0027462039 scopus 로고
    • Cost-effective method for detection of "hook effect" in tumor marker immunometric assays
    • Cole TG, Johnson D, Eveland BJ, Nahm MH. Cost-effective method for detection of "hook effect" in tumor marker immunometric assays [Letter]. Clin Chem 1993;39:695-6.
    • (1993) Clin Chem , vol.39 , pp. 695-696
    • Cole, T.G.1    Johnson, D.2    Eveland, B.J.3    Nahm, M.H.4
  • 27
    • 0023318906 scopus 로고
    • Performance criteria for appropriate characterization of "(highly) sensitive" thyrotropin assays
    • Bayer M. Performance criteria for appropriate characterization of "(highly) sensitive" thyrotropin assays [Letter]. Clin Chem 1987; 33:630-1.
    • (1987) Clin Chem , vol.33 , pp. 630-631
    • Bayer, M.1
  • 28
    • 0011209469 scopus 로고
    • Further developments in TSH technology
    • Spencer C. Further developments in TSH technology. Exp Clin Endocrinol 1994;102:12-22.
    • (1994) Exp Clin Endocrinol , vol.102 , pp. 12-22
    • Spencer, C.1
  • 29
    • 0026718209 scopus 로고
    • Intravenous thyrotropin (TSH)-releasing hormone releases human TSH that is structurally different from basal TSH
    • Magner JA, Kane J, Chou ET, Intravenous thyrotropin (TSH)-releasing hormone releases human TSH that is structurally different from basal TSH. J Clin Endocrinol Metab 1992;74:1306-11.
    • (1992) J Clin Endocrinol Metab , vol.74 , pp. 1306-1311
    • Magner, J.A.1    Kane, J.2    Chou, E.T.3
  • 30
    • 0342521740 scopus 로고
    • Isolation and characterization of different subfractions of human serum thyrotropin (hTSH)
    • Trojan J, Schaaf L, Weis G, Bergmann A, Helton TE, Magner JA, et al. Isolation and characterization of different subfractions of human serum thyrotropin (hTSH). Exp Clin Endocrinol 1994;102: 33-7.
    • (1994) Exp Clin Endocrinol , vol.102 , pp. 33-37
    • Trojan, J.1    Schaaf, L.2    Weis, G.3    Bergmann, A.4    Helton, T.E.5    Magner, J.A.6
  • 31
    • 0009506867 scopus 로고
    • Dissociation between immunological and biological activities of circulating TSH
    • Persani L, Asteria C, Beck-Peccoz P. Dissociation between immunological and biological activities of circulating TSH. Exp Clin Endocrinol 1994;102:38-48.
    • (1994) Exp Clin Endocrinol , vol.102 , pp. 38-48
    • Persani, L.1    Asteria, C.2    Beck-Peccoz, P.3
  • 34
    • 0026610254 scopus 로고
    • Interference in the Allégro immunoassay system when blood is collected in silicone-coated tubes
    • Wickus GG, Mordan RJ, Mathews EA. Interference in the Allégro immunoassay system when blood is collected in silicone-coated tubes [Letter]. Clin Chem 1992;38:2347-8.
    • (1992) Clin Chem , vol.38 , pp. 2347-2348
    • Wickus, G.G.1    Mordan, R.J.2    Mathews, E.A.3
  • 37
    • 0028296617 scopus 로고
    • Control of adrenergic overactivity by B-blockade improves the quality of life in patients receiving long term suppressive therapy with levothyroxine
    • Biondi B, Fazio S, Carella C, Sabatini D, Amato G, Cittadini A, et al. Control of adrenergic overactivity by B-blockade improves the quality of life in patients receiving long term suppressive therapy with levothyroxine. J Clin Endocrinol Metab 1994;78: 1028-33.
    • (1994) J Clin Endocrinol Metab , vol.78 , pp. 1028-1033
    • Biondi, B.1    Fazio, S.2    Carella, C.3    Sabatini, D.4    Amato, G.5    Cittadini, A.6
  • 38
    • 0028926303 scopus 로고
    • Treatment guidelines for patients with hyperthyroidism and hypothyroidism
    • Singer PA, Cooper DS, Levy EG, Ladenson PW, Braverman LE, et al. Treatment guidelines for patients with hyperthyroidism and hypothyroidism. JAMA 1995;273:808-12.
    • (1995) JAMA , vol.273 , pp. 808-812
    • Singer, P.A.1    Cooper, D.S.2    Levy, E.G.3    Ladenson, P.W.4    Braverman, L.E.5
  • 39
    • 0028221214 scopus 로고
    • Comparison of second and third generation methods for measurement of serum thyrotropin in patients with overt hyperthyroidism, patients receiving thyroxine therapy, and those with nonthyroidal illness
    • Franklyn JA, Black EG, Betteridge K, Sheppard MC. Comparison of second and third generation methods for measurement of serum thyrotropin in patients with overt hyperthyroidism, patients receiving thyroxine therapy, and those with nonthyroidal illness. J Clin Endocrinol Metab 1994;78:1368-71.
    • (1994) J Clin Endocrinol Metab , vol.78 , pp. 1368-1371
    • Franklyn, J.A.1    Black, E.G.2    Betteridge, K.3    Sheppard, M.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.