메뉴 건너뛰기




Volumn 69, Issue 817, 1996, Pages 64-69

Short communication: Use of the European image quality criteria for screen-film comparison - Application for asymmetric systems

Author keywords

[No Author keywords available]

Indexed keywords

ANATOMY; ARTICLE; COMPARATIVE STUDY; CONTROLLED STUDY; FEMALE; FILM; HUMAN; IMAGE QUALITY; MALE; PHANTOM; RADIOLOGY; SIMULATION;

EID: 0030020054     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/0007-1285-69-817-64     Document Type: Article
Times cited : (1)

References (13)
  • 2
    • 0028080772 scopus 로고
    • Evaluation of an asymmetric screen-film system for chest radiography
    • MORISHITA, J, McMAHON, H, DOI, K ET AL, Evaluation of an asymmetric screen-film system for chest radiography, Med. Phys., 21, 1769-1775 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1769-1775
    • Morishita, J.1    McMahon, H.2    Doi, K.3
  • 3
    • 0001435228 scopus 로고
    • New chest imaging techniques: A comparison of five analogue and digital methods
    • BUSCH, H P, LEHMANN, K J, DRESCHER, P and GEORGI, M, New chest imaging techniques: a comparison of five analogue and digital methods, Eur. Radiol., 2, 335-341 (1992).
    • (1992) Eur. Radiol. , vol.2 , pp. 335-341
    • Busch, H.P.1    Lehmann, K.J.2    Drescher, P.3    Georgi, M.4
  • 4
    • 0027321113 scopus 로고
    • Evaluation of resolution and sensitometric characteristics of an asymetric screen-film imaging systems
    • GRAY, J E, STEARS, J G, SWENSEN, S J and BUNCH, P C, Evaluation of resolution and sensitometric characteristics of an asymetric screen-film imaging systems, Radiology, 188, 537-539 (1993).
    • (1993) Radiology , vol.188 , pp. 537-539
    • Gray, J.E.1    Stears, J.G.2    Swensen, S.J.3    Bunch, P.C.4
  • 5
    • 0027398152 scopus 로고
    • A new asymmetric screen-film combination for conventional chest radiography: Evaluation in 50 patients
    • SWENSEN, S J, GRAY, J E, BROWN, L R ET AL, A new asymmetric screen-film combination for conventional chest radiography: evaluation in 50 patients, AJR, 160, 483-486 (1993).
    • (1993) AJR , vol.160 , pp. 483-486
    • Swensen, S.J.1    Gray, J.E.2    Brown, L.R.3
  • 6
    • 0027449328 scopus 로고
    • Film-based chest radiography: AMBER vs asymmetric screen-film systems
    • CHOTAS, H G, FLOYD, C E JR and RAVIN, C E, Film-based chest radiography: AMBER vs asymmetric screen-film systems, AJR, 161, 743-747 (1993).
    • (1993) AJR , vol.161 , pp. 743-747
    • Chotas, H.G.1    Floyd Jr., C.E.2    Ravin, C.E.3
  • 7
    • 0028006410 scopus 로고
    • Comparison of a new dual characteristic film-screen system (InSight) with a standard film-screen system for chest radiology
    • LOGAN, P M, TUNNEY, T, McCOY, C T and MASTERSON, J, Comparison of a new dual characteristic film-screen system (InSight) with a standard film-screen system for chest radiology. Br. J. Radiol., 67, 162-165 (1994).
    • (1994) Br. J. Radiol. , vol.67 , pp. 162-165
    • Logan, P.M.1    Tunney, T.2    McCoy, C.T.3    Masterson, J.4
  • 8
    • 0027396187 scopus 로고
    • Portable chest imaging: Comparison of storage phosphor digital system and conventional screen/film system
    • NIKLASON, L T, CHAN, H P, CASCADE, P N ET AL, Portable chest imaging: comparison of storage phosphor digital system and conventional screen/film system, Radiology, 186, 387-393 (1993).
    • (1993) Radiology , vol.186 , pp. 387-393
    • Niklason, L.T.1    Chan, H.P.2    Cascade, P.N.3
  • 9
    • 0028146574 scopus 로고
    • Objective performance characteristics of a new asymmetric screen-film system
    • VAN METTER, R and DICKERSON, R, Objective performance characteristics of a new asymmetric screen-film system, Med. Phys., 21, 1483-1490 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1483-1490
    • Van Metter, R.1    Dickerson, R.2
  • 10
    • 0028213975 scopus 로고
    • Method of simulated screen sensitometry for asymmetric, low crossover medical X-ray films
    • DICKERSON, R, HAUS, A G and BAKER, C W, Method of simulated screen sensitometry for asymmetric, low crossover medical X-ray films, Med. Phys., 21, 525-528 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 525-528
    • Dickerson, R.1    Haus, A.G.2    Baker, C.W.3
  • 12
    • 0028097712 scopus 로고
    • Image quality and patient dose for different screen-film combinations
    • GUIBELALDE, E, FERNANDEZ, J M, VAÑÓ, E ET AL, Image quality and patient dose for different screen-film combinations, Br. J. Radiol., 67, 166-173 (1994).
    • (1994) Br. J. Radiol. , vol.67 , pp. 166-173
    • Guibelalde, E.1    Fernandez, J.M.2    Vañó, E.3
  • 13
    • 0027375344 scopus 로고
    • Relationship between medical requirements and technical parameters of good imaging performance and acceptable dose
    • STIEVE, F E, HAGEMANN, G and STENDER, H, Relationship between medical requirements and technical parameters of good imaging performance and acceptable dose, Radiat. Prot. Dosim., 49, 3-18 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.49 , pp. 3-18
    • Stieve, F.E.1    Hagemann, G.2    Stender, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.