메뉴 건너뛰기




Volumn 25, Issue 1, 1996, Pages 35-38

Drilling in ear surgery: A comparison of pre- and postoperative bone-conduction thresholds in both the conventional and extended high-frequency ranges

Author keywords

Bone conduction; Conventional frequencies; Drilling; Ear surgery; Extended high frequencies

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BONE CONDUCTION; CLINICAL ARTICLE; CONTROLLED STUDY; DRILL; EAR SURGERY; FEMALE; HEARING LOSS; HUMAN; MALE; MASTOIDECTOMY; NOISE; NOISE INJURY; OSTEOMA; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; SCHOOL CHILD;

EID: 0030005914     PISSN: 01050397     EISSN: None     Source Type: Journal    
DOI: 10.3109/01050399609047553     Document Type: Article
Times cited : (12)

References (25)
  • 1
    • 0024427124 scopus 로고
    • Sensorineural high-frequency hearing loss after drill-generated acoustic trauma in tympanoplasty
    • Doménech J, Carulla M, Traserra J. Sensorineural high-frequency hearing loss after drill-generated acoustic trauma in tympanoplasty. Eur Arch Otorhinolaryngol 1989; 246: 280-2.
    • (1989) Eur Arch Otorhinolaryngol , vol.246 , pp. 280-282
    • Doménech, J.1    Carulla, M.2    Traserra, J.3
  • 3
    • 0026627840 scopus 로고
    • High-frequency audiometry: Masking of air- and bone-conduction signals
    • Hallmo P, Sundby A, Mair IWS. High-frequency audiometry: masking of air- and bone-conduction signals. Scand Audiol 1992; 21: 115-21.
    • (1992) Scand Audiol , vol.21 , pp. 115-121
    • Hallmo, P.1    Sundby, A.2    Mair, I.W.S.3
  • 5
    • 0017139697 scopus 로고
    • Acoustic trauma from the bone cutting burr
    • Helms J. Acoustic trauma from the bone cutting burr. J Laryngol Otol 1976; 90: 1143-9.
    • (1976) J Laryngol Otol , vol.90 , pp. 1143-1149
    • Helms, J.1
  • 6
    • 0025776391 scopus 로고
    • Measurement of drill-generated noise levels during ear surgery
    • Hickey SA, O'Connor AFF. Measurement of drill-generated noise levels during ear surgery. J Laryngol Otol 1991; 105: 732-5.
    • (1991) J Laryngol Otol , vol.105 , pp. 732-735
    • Hickey, S.A.1    O'Connor, A.F.F.2
  • 7
    • 0018776227 scopus 로고
    • Peroperative drillgenerated noise levels in ear surgery
    • Stockh
    • Holmquist J, Oleander R, Hallén O. Peroperative drillgenerated noise levels in ear surgery. Acta Otolaryngol (Stockh) 1979; 87: 458-60.
    • (1979) Acta Otolaryngol , vol.87 , pp. 458-460
    • Holmquist, J.1    Oleander, R.2    Hallén, O.3
  • 9
    • 0017171550 scopus 로고
    • Drill-generated noise levels in ear surgery
    • Stockh
    • Kylén P, Arlinger S. Drill-generated noise levels in ear surgery. Acta Otolaryngol (Stockh) 1976; 82: 402-9.
    • (1976) Acta Otolaryngol , vol.82 , pp. 402-409
    • Kylén, P.1    Arlinger, S.2
  • 10
    • 0017715049 scopus 로고
    • Peroperative temporary threshold shift in ear surgery
    • Stockh
    • Kylén P. Arlinger SD, Bergholtz LM. Peroperative temporary threshold shift in ear surgery. Acta Otolaryngol (Stockh) 1977; 84: 393-401.
    • (1977) Acta Otolaryngol , vol.84 , pp. 393-401
    • Kylén, P.1    Arlinger, S.D.2    Bergholtz, L.M.3
  • 11
    • 0028106865 scopus 로고
    • Myringoplasty: A conventional and extended high-frequency, air- and bone-conduction audiometric study
    • Mair IWS, Hallmo P. Myringoplasty: a conventional and extended high-frequency, air- and bone-conduction audiometric study. Scand Audiol 1994; 23: 205-8.
    • (1994) Scand Audiol , vol.23 , pp. 205-208
    • Mair, I.W.S.1    Hallmo, P.2
  • 12
    • 0022508847 scopus 로고
    • Air conduction thresholds after myringoplasty and stapes surgery: A conventional and high frequency audiometric comparison
    • Mair IWS, Laukli E. Air conduction thresholds after myringoplasty and stapes surgery: a conventional and high frequency audiometric comparison Ann Otol Rhinol Laryngol 1986; 95: 327-30.
    • (1986) Ann Otol Rhinol Laryngol , vol.95 , pp. 327-330
    • Mair, I.W.S.1    Laukli, E.2
  • 13
    • 0021860655 scopus 로고
    • Does drill noise during mastoid surgery affect the contralateral ear?
    • Man A, Winerman I. Does drill noise during mastoid surgery affect the contralateral ear? Am J Otol 1985, 6: 334-5.
    • (1985) Am J Otol , vol.6 , pp. 334-335
    • Man, A.1    Winerman, I.2
  • 14
    • 0015851374 scopus 로고
    • High-tone sensorineural losses following chronic ear surgery
    • Palva T, Kärjä J, Palva A. High-tone sensorineural losses following chronic ear surgery. Arch Otolaryngol Head Neck Surg 1973; 98: 176-8.
    • (1973) Arch Otolaryngol Head Neck Surg , vol.98 , pp. 176-178
    • Palva, T.1    Kärjä, J.2    Palva, A.3
  • 15
    • 0018339314 scopus 로고
    • Can an operation on a deaf ear be dangerous for hearing?
    • Stockh
    • Palva A, Sorri M. Can an operation on a deaf ear be dangerous for hearing? Acta Otolaryngol (Stockh) 1979; (Suppl 360): 155-7.
    • (1979) Acta Otolaryngol , Issue.360 SUPPL. , pp. 155-157
    • Palva, A.1    Sorri, M.2
  • 17
    • 0001213472 scopus 로고
    • Acoustic trauma of the cochlea from ear surgery
    • Schuknecht HF, Tonndorf J. Acoustic trauma of the cochlea from ear surgery. Laryngoscope 1960; 70: 479-505.
    • (1960) Laryngoscope , vol.70 , pp. 479-505
    • Schuknecht, H.F.1    Tonndorf, J.2
  • 18
    • 0001850956 scopus 로고
    • Sensorineural hearing loss in chronic ear surgery
    • Smyth GDL. Sensorineural hearing loss in chronic ear surgery. Ann Otol Rhinol Laryngol 1977; 86: 3-8.
    • (1977) Ann Otol Rhinol Laryngol , vol.86 , pp. 3-8
    • Smyth, G.D.L.1
  • 19
    • 0027429881 scopus 로고
    • Effect of otologic drill noise on ABR thresholds in a guinea pig model
    • Suits GW, Brummett RE, Nunley J. Effect of otologic drill noise on ABR thresholds in a guinea pig model. Otolaryngol Head Neck Surg 1993; 109: 660-7.
    • (1993) Otolaryngol Head Neck Surg , vol.109 , pp. 660-667
    • Suits, G.W.1    Brummett, R.E.2    Nunley, J.3
  • 20
    • 0021223250 scopus 로고
    • Sensorineural hearing loss following chronic ear surgery
    • Tos M, Lau T, Plate S. Sensorineural hearing loss following chronic ear surgery. Ann Otol Rhinol Laryngol 1984; 93: 403-9.
    • (1984) Ann Otol Rhinol Laryngol , vol.93 , pp. 403-409
    • Tos, M.1    Lau, T.2    Plate, S.3
  • 21
    • 0024458188 scopus 로고
    • The contralateral ear after translabyrinthine removal of acoustic neuromas: Is there a drill-noise generated hearing loss?
    • Tos M, Trojaborg N, Thomsen J. The contralateral ear after translabyrinthine removal of acoustic neuromas: is there a drill-noise generated hearing loss? J Laryngol Otol 1989; 103: 845-9.
    • (1989) J Laryngol Otol , vol.103 , pp. 845-849
    • Tos, M.1    Trojaborg, N.2    Thomsen, J.3
  • 22
    • 0026697237 scopus 로고
    • Drillgenerated sensorineural hearing loss following mastoid surgery
    • Urquhart AC, McIntosh WA, Bodenstein NP. Drillgenerated sensorineural hearing loss following mastoid surgery. Laryngoscope 1992, 102: 689-92.
    • (1992) Laryngoscope , vol.102 , pp. 689-692
    • Urquhart, A.C.1    McIntosh, W.A.2    Bodenstein, N.P.3
  • 25
    • 0023888904 scopus 로고
    • High-frequency audiometry: Comparison of electric bond-conduction and airconduction thresholds
    • Økstad S, Laukli E, Mair IWS. High-frequency audiometry: comparison of electric bond-conduction and airconduction thresholds. Audiology 1988; 27: 17-26.
    • (1988) Audiology , vol.27 , pp. 17-26
    • Økstad, S.1    Laukli, E.2    Mair, I.W.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.