메뉴 건너뛰기




Volumn 12, Issue 2, 1996, Pages

Corneal topography for intraocular lens power calculations

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ASTIGMATISM; CASE REPORT; CATARACT EXTRACTION; CLINICAL TRIAL; COMPUTER ANALYSIS; CONFERENCE PAPER; CORNEA; FEMALE; HUMAN; KERATOMETRY; LENS IMPLANT; LENS POWER; MALE; PRIORITY JOURNAL; TOPOGRAPHY; VIDEORECORDING; VISUAL ACUITY;

EID: 0030005748     PISSN: 08830444     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (18)

References (6)
  • 1
    • 0027179635 scopus 로고
    • Comparison of the accuracy of computerized videokeratography and keratometry for use in intraocular lens calculation
    • Cuaycong MJ, Gay CA, Emery J, Haft EA, Koch DD. Comparison of the accuracy of computerized videokeratography and keratometry for use in intraocular lens calculation. J Cataract Refract Surg. 1993;19(suppl):178-181.
    • (1993) J Cataract Refract Surg , vol.19 , Issue.SUPPL. , pp. 178-181
    • Cuaycong, M.J.1    Gay, C.A.2    Emery, J.3    Haft, E.A.4    Koch, D.D.5
  • 2
    • 0027317877 scopus 로고
    • When keratometric measurements do not accurately reflect corneal topography
    • Sanders DR, Gills JG, Martin RG. When keratometric measurements do not accurately reflect corneal topography. J Cataract Refract Surg. 1993;19(suppl):131-135.
    • (1993) J Cataract Refract Surg , vol.19 , Issue.SUPPL. , pp. 131-135
    • Sanders, D.R.1    Gills, J.G.2    Martin, R.G.3
  • 3
    • 0026065647 scopus 로고
    • Quantitative descriptors of corneal topography. A clinical study
    • Wilson SE, Klyce SD. Quantitative descriptors of corneal topography. A clinical study. Arch Ophthalmol. 1991;109: 349-353.
    • (1991) Arch Ophthalmol , vol.109 , pp. 349-353
    • Wilson, S.E.1    Klyce, S.D.2
  • 4
    • 0026061762 scopus 로고
    • Advances in the analysis of corneal topography
    • Wilson SE, Klyce, SD. Advances in the analysis of corneal topography. Survey of Ophthalmol. 1991;35:269-277.
    • (1991) Survey of Ophthalmol , vol.35 , pp. 269-277
    • Wilson, S.E.1    Klyce, S.D.2
  • 5
    • 0024949711 scopus 로고
    • Quantitative descriptors of corneal shape derived from computer-assisted analysis of photokeratography
    • Dingeldein SA, Klyce SD, Wilson SE. Quantitative descriptors of corneal shape derived from computer-assisted analysis of photokeratography. Refractive and Corneal Surgery 1989;5:372-378.
    • (1989) Refractive and Corneal Surgery , vol.5 , pp. 372-378
    • Dingeldein, S.A.1    Klyce, S.D.2    Wilson, S.E.3
  • 6
    • 0025992164 scopus 로고
    • Corneal topography for selective suture removal after penetrating keratoplasty
    • Strelow S, Cohen EJ, Leavitt KJ, Laibson PR. Corneal topography for selective suture removal after penetrating keratoplasty. Am J Ophthalmol. 1991;112:657-665.
    • (1991) Am J Ophthalmol , vol.112 , pp. 657-665
    • Strelow, S.1    Cohen, E.J.2    Leavitt, K.J.3    Laibson, P.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.