메뉴 건너뛰기




Volumn 19, Issue 11 II, 1996, Pages 2004-2008

In vitro and in vivo results of transcatheter microwave ablation using forward-firing tip antenna design

Author keywords

ablation; microwave

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; CATHETER ABLATION; DOG; HEART ARRHYTHMIA; HEATING; MICROWAVE RADIATION; NONHUMAN; RADIOFREQUENCY; TREATMENT OUTCOME;

EID: 0029999525     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1996.tb03270.x     Document Type: Article
Times cited : (21)

References (6)
  • 1
    • 0026931368 scopus 로고
    • Evaluation of microwave and radiofrequency catheter ablation in a myocardium-equivalent phantom model
    • Wonnell TL, Stauffer PR, Langberg J. Evaluation of microwave and radiofrequency catheter ablation in a myocardium-equivalent phantom model. IEEE Trans Biomed Eng 1992; 39:1086-1095.
    • (1992) IEEE Trans Biomed Eng , vol.39 , pp. 1086-1095
    • Wonnell, T.L.1    Stauffer, P.R.2    Langberg, J.3
  • 2
    • 0028274879 scopus 로고
    • Microwave ablation of the atrioventricular junction in vivo and ventricular myocardium in vitro and in vivo. Effects of varying power and duration on lesion volume
    • Yang X, Watanabe I, Kojima T, et al. Microwave ablation of the atrioventricular junction in vivo and ventricular myocardium in vitro and in vivo. Effects of varying power and duration on lesion volume. Jpn Heart J 1994; 35:175-191.
    • (1994) Jpn Heart J , vol.35 , pp. 175-191
    • Yang, X.1    Watanabe, I.2    Kojima, T.3
  • 3
    • 0029199726 scopus 로고
    • Microwave ablation of the atrioventricular junction in open-chest dogs
    • Lin JC, Beckman KJ, Hariman RJ, et al. Microwave ablation of the atrioventricular junction in open-chest dogs. Bioelectromagnetics 1995; 16:97-105.
    • (1995) Bioelectromagnetics , vol.16 , pp. 97-105
    • Lin, J.C.1    Beckman, K.J.2    Hariman, R.J.3
  • 4
    • 0028209986 scopus 로고
    • Microwave catheter ablation of myocardium in vitro. Assessment of the characteristics of tissue heating and injury
    • Whayne JG, Nath S, Haines DE. Microwave catheter ablation of myocardium in vitro. Assessment of the characteristics of tissue heating and injury. Circulation 1994; 89:2390-2395.
    • (1994) Circulation , vol.89 , pp. 2390-2395
    • Whayne, J.G.1    Nath, S.2    Haines, D.E.3
  • 5
    • 0030106206 scopus 로고    scopus 로고
    • Ablation for the treatment of arrhythmias
    • McCrury ID, Haines DE. Ablation for the treatment of arrhythmias. Proc IEEE 1996; 84:404-416.
    • (1996) Proc IEEE , vol.84 , pp. 404-416
    • McCrury, I.D.1    Haines, D.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.