메뉴 건너뛰기




Volumn 35, Issue 4, 1996, Pages 563-568

Phase-modulated binomial RF pulses for fast spectrally-selective musculoskeletal imaging

Author keywords

fat suppression; jump and return; musculoskeletal

Indexed keywords

CHEMICAL SHIFT; MUSCULOSKELETAL SYSTEM;

EID: 0029998974     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910350416     Document Type: Article
Times cited : (41)

References (11)
  • 1
    • 0023628727 scopus 로고
    • Cartilage disorders: Comparison of spin-echo, CHESS, and Flash sequence MR images
    • H. Konig, R. Sauter, M. Deimling, M. Vogt, Cartilage disorders: comparison of spin-echo, CHESS, and Flash sequence MR images. Radiology 164, 753-758 (1987).
    • (1987) Radiology , vol.164 , pp. 753-758
    • Konig, H.1    Sauter, R.2    Deimling, M.3    Vogt, M.4
  • 2
    • 0027458723 scopus 로고
    • Intrinsic and extrinsic carpal ligaments: Evaluation by three-dimensional Fourier transform MR imaging
    • S. M. S. Totterman, R. Miller, B. Wasserman, J. S. Blebea. D. J. Rubens, Intrinsic and extrinsic carpal ligaments: evaluation by three-dimensional Fourier transform MR imaging. AJR 160, 117-123 (1993).
    • (1993) AJR , vol.160 , pp. 117-123
    • Totterman, S.M.S.1    Miller, R.2    Wasserman, B.3    Blebea, J.S.4    Rubens, D.J.5
  • 6
    • 0022260365 scopus 로고
    • MR imaging: Clinical use of the inversion recovery sequence
    • G. M. Bydder, I. R. Young, MR imaging: clinical use of the inversion recovery sequence. J. Comput. Assist. Tomogr. 9, 659-675 (1985).
    • (1985) J. Comput. Assist. Tomogr. , vol.9 , pp. 659-675
    • Bydder, G.M.1    Young, I.R.2
  • 7
    • 85035165685 scopus 로고    scopus 로고
    • Frequency-selective excitation using shaped RF pulses with adiabatic characteristics
    • D. P. Flaming, R. H. Griffey, Frequency-selective excitation using shaped RF pulses with adiabatic characteristics, in "Abstracts, SMRM, 10th Annual Meeting, 1991," p. 484.
    • Abstracts, SMRM, 10th Annual Meeting, 1991 , pp. 484
    • Flaming, D.P.1    Griffey, R.H.2
  • 8
    • 33845555707 scopus 로고
    • Exchangeable proton NMR without base-line distortion, using new strong-pulse sequences
    • P. Plateau, M. Gueron, Exchangeable proton NMR without base-line distortion, using new strong-pulse sequences. J. Am. Chem. Soc. 104, 7310-7311 (1982).
    • (1982) J. Am. Chem. Soc. , vol.104 , pp. 7310-7311
    • Plateau, P.1    Gueron, M.2
  • 9
    • 48749149745 scopus 로고
    • Solvent suppression in Fourier transform nuclear magnetic resonance
    • P. J. Hore, Solvent suppression in Fourier transform nuclear magnetic resonance. J. Magn. Reson. 55, 283-300 (1983).
    • (1983) J. Magn. Reson. , vol.55 , pp. 283-300
    • Hore, P.J.1
  • 11
    • 0023924236 scopus 로고
    • A new steady-state imaging sequence for simultaneous acquisition of two MR images with clearly different contrasts
    • H. Bruder, H. Fischer, R. Graumann, M. Deimling, A new steady-state imaging sequence for simultaneous acquisition of two MR images with clearly different contrasts. Magn. Reson. Med. 7, 35-42 (1988).
    • (1988) Magn. Reson. Med. , vol.7 , pp. 35-42
    • Bruder, H.1    Fischer, H.2    Graumann, R.3    Deimling, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.