메뉴 건너뛰기




Volumn 21, Issue 5, 1996, Pages 323-327

Inspiratory work of breathing in ventilated preterm infants

Author keywords

continuous positive end expiratory airway pressure (CPAP); intrinsic positive end expiratory pressure (PEEP(i)); Mechanical ventilation; work of breathing

Indexed keywords

ARTICLE; ARTIFICIAL VENTILATION; BREATHING; BREATHING MUSCLE; CLINICAL ARTICLE; ESOPHAGUS PRESSURE; HUMAN; INFANT; INSPIRATORY CAPACITY; LUNG FUNCTION TEST; LUNG VENTILATION; POSITIVE END EXPIRATORY PRESSURE; PREMATURITY; PRESSURE VOLUME CURVE; PRIORITY JOURNAL;

EID: 0029996797     PISSN: 87556863     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1099-0496(199605)21:5<323::AID-PPUL8>3.0.CO;2-N     Document Type: Article
Times cited : (6)

References (23)
  • 2
    • 0028902296 scopus 로고
    • Improved oxygenation during synchronized intermittent mandatory ventilation in neonates with respiratory distress syndrome: A randomized cross-over study
    • Cleary JP, Bernstein G, Mannino FL. Heldt G. Improved oxygenation during synchronized intermittent mandatory ventilation in neonates with respiratory distress syndrome: A randomized cross-over study. J Pediatr. 1995; 126:407-411.
    • (1995) J Pediatr. , vol.126 , pp. 407-411
    • Cleary, J.P.1    Bernstein, G.2    Mannino, F.L.3    Heldt, G.4
  • 3
    • 0027944998 scopus 로고
    • Increased and more consistent tidal volumes during synchronized intermittent mandatory ventilation in newborn infants
    • Bernstein G, Heldt GP, Mannino FL. Increased and more consistent tidal volumes during synchronized intermittent mandatory ventilation in newborn infants. Am J Respir Crit Care Med. 1994; 150:1444-1448.
    • (1994) Am J Respir Crit Care Med. , vol.150 , pp. 1444-1448
    • Bernstein, G.1    Heldt, G.P.2    Mannino, F.L.3
  • 7
    • 0024533259 scopus 로고
    • Inspiratory pressure support prevents diaphragmatic fatigue during weaning from mechanical ventilation
    • Brochard L, Harf A, Lorino H, Lemaire F. Inspiratory pressure support prevents diaphragmatic fatigue during weaning from mechanical ventilation. Am Rev Respir Dis. 1989; 139:513-521.
    • (1989) Am Rev Respir Dis. , vol.139 , pp. 513-521
    • Brochard, L.1    Harf, A.2    Lorino, H.3    Lemaire, F.4
  • 8
    • 0026054873 scopus 로고
    • Inspiratory pressure support compensates for the additional work of breathing caused by endotracheal tube
    • Brochard L, Rua F, Lorino H, Lemaire F, Harf A. Inspiratory pressure support compensates for the additional work of breathing caused by endotracheal tube. Anesthesiology. 1991; 75:739-745.
    • (1991) Anesthesiology , vol.75 , pp. 739-745
    • Brochard, L.1    Rua, F.2    Lorino, H.3    Lemaire, F.4    Harf, A.5
  • 9
    • 0020374426 scopus 로고
    • Oesophageal pressure measurements in ventilated preterm babies
    • Greenough A, Morley JC. Oesophageal pressure measurements in ventilated preterm babies. Arch Dis Child. 1982; 57:851-855.
    • (1982) Arch Dis Child , vol.57 , pp. 851-855
    • Greenough, A.1    Morley, J.C.2
  • 10
    • 0026000402 scopus 로고
    • Patient triggered ventilation using a flow triggered system
    • Hird MF, Greenough A. Patient triggered ventilation using a flow triggered system. Arch Dis Child. 1991; 66:1140-1142.
    • (1991) Arch Dis Child , vol.66 , pp. 1140-1142
    • Hird, M.F.1    Greenough, A.2
  • 12
    • 0026274978 scopus 로고
    • Esophageal pressure manometry in human infants
    • Coates AL, Stocks J. Esophageal pressure manometry in human infants. Pediatr Pulmonol. 1991; 11:350-360.
    • (1991) Pediatr Pulmonol. , vol.11 , pp. 350-360
    • Coates, A.L.1    Stocks, J.2
  • 13
    • 2542548686 scopus 로고
    • Energetics
    • Lenfant CE, ed. New York: Marcel Dekker
    • Roussos C, Energetics. In: Lenfant CE, ed. The Thorax. New York: Marcel Dekker, 1985:437-492.
    • (1985) The Thorax , pp. 437-492
    • Roussos, C.1
  • 14
    • 0023685509 scopus 로고
    • External work output and force generation during synchronized intermittent mandatory ventilation
    • Marini JJ, Smith TC, Lamb V. External work output and force generation during synchronized intermittent mandatory ventilation. Am Rev Respir Dis. 1988; 138:1169-1179.
    • (1988) Am Rev Respir Dis. , vol.138 , pp. 1169-1179
    • Marini, J.J.1    Smith, T.C.2    Lamb, V.3
  • 15
    • 0028350283 scopus 로고
    • Patient work of breathing during pressure support and volume-cycled mechanical ventilation
    • Kreit JW, Capper MW, Eschenbacher WL. Patient work of breathing during pressure support and volume-cycled mechanical ventilation. Am J Respir Crit Care Med. 1994; 149:1085-1091.
    • (1994) Am J Respir Crit Care Med. , vol.149 , pp. 1085-1091
    • Kreit, J.W.1    Capper, M.W.2    Eschenbacher, W.L.3
  • 16
    • 0023810275 scopus 로고
    • Evaluation of neonatal pulmonary mechanics and energetics: A two factor least mean square analysis
    • Bhutani VK, Sivieri EM, Abbasi S, Shaffer TH. Evaluation of neonatal pulmonary mechanics and energetics: A two factor least mean square analysis. Pediatr Pulmonol. 1988; 4:150-158.
    • (1988) Pediatr Pulmonol. , vol.4 , pp. 150-158
    • Bhutani, V.K.1    Sivieri, E.M.2    Abbasi, S.3    Shaffer, T.H.4
  • 17
    • 0000573899 scopus 로고
    • Respiratory muscle energetics
    • Section 3, Respiration. Bethesda: American Physiologial Society
    • Roussos C, Campbell EJM. Respiratory muscle energetics. In: Handbook of Physiology. Section 3, Vol. 3: Respiration. Bethesda: American Physiologial Society, 1986:481-509.
    • (1986) Handbook of Physiology , vol.3 , pp. 481-509
    • Roussos, C.1    Campbell, E.J.M.2
  • 18
    • 0001300074 scopus 로고
    • Volume-pressure relationships of the thorax and lung in the newborn
    • Agostini E. Volume-pressure relationships of the thorax and lung in the newborn. J Appl Physiol. 1959; 14:909-913.
    • (1959) J Appl Physiol. , vol.14 , pp. 909-913
    • Agostini, E.1
  • 19
    • 0025166978 scopus 로고
    • Causes of failure of neonatal patient triggered ventilation
    • Hird MF, Greenough A. Causes of failure of neonatal patient triggered ventilation. Early Hum Dev. 1990; 23:101-108.
    • (1990) Early Hum Dev. , vol.23 , pp. 101-108
    • Hird, M.F.1    Greenough, A.2
  • 20
    • 0019989011 scopus 로고
    • Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction
    • Pepe PE, Marini JJ. Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction. Am Rev Respir Dis. 1982; 126 166-170.
    • (1982) Am Rev Respir Dis. , vol.126 , pp. 166-170
    • Pepe, P.E.1    Marini, J.J.2
  • 21
    • 0024790361 scopus 로고
    • Effects of pressure support on breathing patterns and respiratory work
    • Tokioka H, Saito S, Kosaka F. Effects of pressure support on breathing patterns and respiratory work. Intens Care Med. 1989; 15:491-494.
    • (1989) Intens Care Med. , vol.15 , pp. 491-494
    • Tokioka, H.1    Saito, S.2    Kosaka, F.3
  • 22
    • 0022623539 scopus 로고
    • Inadvertent positive end-expiratory pressure in mechanically ventilated newborn infants: Detection and effect on lung mechanics and gas exchange
    • Simbruner G. Inadvertent positive end-expiratory pressure in mechanically ventilated newborn infants: Detection and effect on lung mechanics and gas exchange. J Pediatr. 1986; 108:589-595.
    • (1986) J Pediatr. , vol.108 , pp. 589-595
    • Simbruner, G.1
  • 23
    • 0023212086 scopus 로고
    • Ventilator settings for newborn infants
    • Ramsden CA, Reynolds EOR. Ventilator settings for newborn infants. Arch Dis Child. 1987; 62:529-538.
    • (1987) Arch Dis Child , vol.62 , pp. 529-538
    • Ramsden, C.A.1    Reynolds, E.O.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.