메뉴 건너뛰기




Volumn 13, Issue 6, 1996, Pages 514-519

Glycated proteins as indices of glycaemic control in diabetic patients with chronic renal failure

Author keywords

Chronic renal failure; Fructosamine; Glycated haemoglobin

Indexed keywords

ALBUMIN; CREATININE; FRUCTOSAMINE; GLUCOSE; GLYCOSYLATED HEMOGLOBIN; URATE; UREA;

EID: 0029994336     PISSN: 07423071     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1096-9136(199606)13:6<514::AID-DIA108>3.0.CO;2-4     Document Type: Article
Times cited : (33)

References (25)
  • 2
    • 0025648812 scopus 로고
    • Glycated haemoglobin and fructosamine in non-diabetic subjects with chronic renal failure
    • Morgan L, Marenah C, Morgan A, Burden R, John W. Glycated haemoglobin and fructosamine in non-diabetic subjects with chronic renal failure. Nephrol Dial Transplant 1990; 5: 868-873.
    • (1990) Nephrol Dial Transplant , vol.5 , pp. 868-873
    • Morgan, L.1    Marenah, C.2    Morgan, A.3    Burden, R.4    John, W.5
  • 3
    • 0018355777 scopus 로고
    • Glycosylated haemoglobin in chronic renal failure
    • Dandona R, Freedman D, Moorhead J. Glycosylated haemoglobin in chronic renal failure. Br Med J 1979; 1: 1183-1184.
    • (1979) Br Med J , vol.1 , pp. 1183-1184
    • Dandona, R.1    Freedman, D.2    Moorhead, J.3
  • 4
    • 0014213703 scopus 로고
    • Haemolysis in chronic renal failure
    • Shaw AB. Haemolysis in chronic renal failure. Br Med J 1967; 2: 213-216.
    • (1967) Br Med J , vol.2 , pp. 213-216
    • Shaw, A.B.1
  • 6
    • 0023229352 scopus 로고
    • Effect of fluctuations in albumin on serum fructosamine assay
    • McCance D, Coulter D, Syme M, Kennedy L. Effect of fluctuations in albumin on serum fructosamine assay. Diabetic Med 1987; 4: 434-436.
    • (1987) Diabetic Med , vol.4 , pp. 434-436
    • McCance, D.1    Coulter, D.2    Syme, M.3    Kennedy, L.4
  • 7
    • 0040743215 scopus 로고
    • Influence of variations in albumin or total protein concentration on serum fructosamine concentration
    • Van Dieijen-Visser M, Seynaeve C, Brombacker P. Influence of variations in albumin or total protein concentration on serum fructosamine concentration (Letter). Clin Chem 1986; 32: 1610.
    • (1986) Clin Chem , vol.32 , pp. 1610
    • Van Dieijen-Visser, M.1    Seynaeve, C.2    Brombacker, P.3
  • 8
    • 0023634920 scopus 로고
    • Assay of serum fructosamine that minimizes standardisation and matrix problems: Use to assess components of biological variation
    • Howey J, Bromning M, Fraser C. Assay of serum fructosamine that minimizes standardisation and matrix problems: use to assess components of biological variation. Clin Chem 1987; 33: 269-272.
    • (1987) Clin Chem , vol.33 , pp. 269-272
    • Howey, J.1    Bromning, M.2    Fraser, C.3
  • 9
    • 8944241748 scopus 로고
    • Glycated haemoglobin analysis: A recommended procedure for the affinity chromatography method
    • John W. Glycated haemoglobin analysis: a recommended procedure for the affinity chromatography method. Ann Clin Biochem 1987; 24: S158.
    • (1987) Ann Clin Biochem , vol.24
    • John, W.1
  • 10
    • 0020966106 scopus 로고
    • An inexpensive, rapid and precise affinity chromatography method for the measurement of glycosylated haemoglobins
    • Hall P, Cook J, Could B. An inexpensive, rapid and precise affinity chromatography method for the measurement of glycosylated haemoglobins. Ann Clin Biochem 1983; 20: 129-135.
    • (1983) Ann Clin Biochem , vol.20 , pp. 129-135
    • Hall, P.1    Cook, J.2    Could, B.3
  • 11
    • 0020655989 scopus 로고
    • Fructosamine: A new approach to the estimation of serum glycosyl-protein. An index of diabetic control
    • Johnson R, Metcalf P, Baker J. Fructosamine: a new approach to the estimation of serum glycosyl-protein. An index of diabetic control. Clin Chem Acta 1982; 127: 87-95.
    • (1982) Clin Chem Acta , vol.127 , pp. 87-95
    • Johnson, R.1    Metcalf, P.2    Baker, J.3
  • 12
    • 0025765912 scopus 로고
    • A comparison of home glucose monitoring with determinants of hemoglobin A1c, total glycated hemoglobin, fructosamine, and random serum glucose in diabetic patients
    • Gebhart S, Wheaton R, Mullins R, Austin G. A comparison of home glucose monitoring with determinants of hemoglobin A1c, total glycated hemoglobin, fructosamine, and random serum glucose in diabetic patients. Arch Int Med 1991; 151: 1133-1137.
    • (1991) Arch Int Med , vol.151 , pp. 1133-1137
    • Gebhart, S.1    Wheaton, R.2    Mullins, R.3    Austin, G.4
  • 13
    • 0027409022 scopus 로고
    • Use of fructosamine and glycated hemoglobin to verify self blood glucose monitoring data in diabetic pregnancy
    • Parfitt V, Clark J, Turner C, Hartog M. Use of fructosamine and glycated hemoglobin to verify self blood glucose monitoring data in diabetic pregnancy. Diabetic Med 1993; 10: 162-166.
    • (1993) Diabetic Med , vol.10 , pp. 162-166
    • Parfitt, V.1    Clark, J.2    Turner, C.3    Hartog, M.4
  • 16
    • 0023276927 scopus 로고
    • Relationship between albumin and fructosamine concentration in diabetic and non-diabetic sera
    • Johnson R, Metcalf P, Baker J. Relationship between albumin and fructosamine concentration in diabetic and non-diabetic sera. Clin Chem Acta 1987; 164: 151-162.
    • (1987) Clin Chem Acta , vol.164 , pp. 151-162
    • Johnson, R.1    Metcalf, P.2    Baker, J.3
  • 17
    • 0024429587 scopus 로고
    • Clinical evaluation of serum fructosamine in monitoring elderly outpatient diabetics
    • Cefalu W, Prather K, Murphy W, Parker T. Clinical evaluation of serum fructosamine in monitoring elderly outpatient diabetics. J Amer Geriatric Soc 1989; 37: 833-837.
    • (1989) J Amer Geriatric Soc , vol.37 , pp. 833-837
    • Cefalu, W.1    Prather, K.2    Murphy, W.3    Parker, T.4
  • 18
    • 0026408054 scopus 로고
    • Fructosamine test-plus, a modified fructosamine assay evaluated
    • Baker J, Metcalf P, Scragg R, Johnson R. Fructosamine test-plus, a modified fructosamine assay evaluated. Clin Chem 1991; 37: 552-556.
    • (1991) Clin Chem , vol.37 , pp. 552-556
    • Baker, J.1    Metcalf, P.2    Scragg, R.3    Johnson, R.4
  • 19
    • 0024616052 scopus 로고
    • Serum fructosamine assay: Influence of serum protein concentrations
    • Oimomi M, Matusa S. Serum fructosamine assay: Influence of serum protein concentrations. Diabetologia 1989; 32: 146.
    • (1989) Diabetologia , vol.32 , pp. 146
    • Oimomi, M.1    Matusa, S.2
  • 20
    • 0025186222 scopus 로고
    • Automated fructosamine assay with improved accuracy used to quantify non-enzymatic glycation of serum proteins in diabetes mellitus and chronic renal failure
    • Tas S, Zein E, Din R. Automated fructosamine assay with improved accuracy used to quantify non-enzymatic glycation of serum proteins in diabetes mellitus and chronic renal failure. Clin Chem 1990; 36: 1825-1830.
    • (1990) Clin Chem , vol.36 , pp. 1825-1830
    • Tas, S.1    Zein, E.2    Din, R.3
  • 22
    • 0026688405 scopus 로고
    • The inter-relationships between albuminuria, plasma albumin concentration and indices of glycaemic control in non-insulin-dependent diabetes mellitus
    • Chan J, Yeung V, Cheung C, Swaminathan R, Cockram C. The inter-relationships between albuminuria, plasma albumin concentration and indices of glycaemic control in non-insulin-dependent diabetes mellitus. Clin Chim Acta 1992; 210: 179-185.
    • (1992) Clin Chim Acta , vol.210 , pp. 179-185
    • Chan, J.1    Yeung, V.2    Cheung, C.3    Swaminathan, R.4    Cockram, C.5
  • 23
    • 0018973382 scopus 로고
    • Re-appraisal of protein losses in patients undergoing continuous ambulatory peritoneal dialysis
    • Katirtzoglou A, Oreopoulos D, Husdan H, Leung M, Ogilvie R, Dombros N. Re-appraisal of protein losses in patients undergoing continuous ambulatory peritoneal dialysis. Nephron 1980; 26: 230-233.
    • (1980) Nephron , vol.26 , pp. 230-233
    • Katirtzoglou, A.1    Oreopoulos, D.2    Husdan, H.3    Leung, M.4    Ogilvie, R.5    Dombros, N.6
  • 24
    • 0024209729 scopus 로고
    • Fructosamine concentration changes in serum during haemodialysis of kidney disease patients
    • Brighton M, Furth A. Fructosamine concentration changes in serum during haemodialysis of kidney disease patients. Clin Chem 1988; 34: 2378-2379.
    • (1988) Clin Chem , vol.34 , pp. 2378-2379
    • Brighton, M.1    Furth, A.2
  • 25
    • 0025939699 scopus 로고
    • Clinical validation of a second generation fructosamine assay
    • Cefalu W, Bell-Farrow A, Petty M, Izlarr C, Smith J. Clinical validation of a second generation fructosamine assay. Clin Chem 1991; 37: 1252-1256.
    • (1991) Clin Chem , vol.37 , pp. 1252-1256
    • Cefalu, W.1    Bell-Farrow, A.2    Petty, M.3    Izlarr, C.4    Smith, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.