메뉴 건너뛰기




Volumn 27, Issue 7, 1996, Pages 1187-1191

Fluid-attenuated inversion recovery (FLAIR) for assessment of cerebral infarction: Initial clinical experience in 50 patients

Author keywords

cerebral infarction; cerebral ischemia; diagnostic imaging; magnetic resonance imaging

Indexed keywords

ADULT; ARTICLE; BASAL GANGLION; BRAIN HEMORRHAGE; BRAIN INFARCTION; BRAIN ISCHEMIA; CEREBROSPINAL FLUID; CEREBROVASCULAR ACCIDENT; CEREBROVASCULAR DISEASE; CLINICAL ARTICLE; CLINICAL PROTOCOL; HUMAN; IMAGE QUALITY; MALE; MICROANGIOPATHY; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RADIATION ATTENUATION;

EID: 0029993002     PISSN: 00392499     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.STR.27.7.1187     Document Type: Article
Times cited : (157)

References (15)
  • 1
    • 0020064292 scopus 로고
    • High frequency CT findings within 24 hours after cerebral infarction
    • Wall SD, Brant-Zawadzki M, Jeffrey RB, Barnes B. High frequency CT findings within 24 hours after cerebral infarction. Am J Radiol. 1982;138:307-311.
    • (1982) Am J Radiol , vol.138 , pp. 307-311
    • Wall, S.D.1    Brant-Zawadzki, M.2    Jeffrey, R.B.3    Barnes, B.4
  • 2
    • 0025039919 scopus 로고
    • Loss of insular ribbon: Another early CT sign of acute middle cerebral artery infarction
    • Truwit CL, Barkovich AJ, Gean-Marton A, Hibri N, Norman D. Loss of insular ribbon: another early CT sign of acute middle cerebral artery infarction. Radiology. 1990;176:801-806.
    • (1990) Radiology , vol.176 , pp. 801-806
    • Truwit, C.L.1    Barkovich, A.J.2    Gean-Marton, A.3    Hibri, N.4    Norman, D.5
  • 9
    • 0026661430 scopus 로고
    • Stroke with negative brain magnetic resonance imaging
    • Alberts MJ, Faulstich ME, Gray L. Stroke with negative brain magnetic resonance imaging. Stroke. 1992;23:663-667.
    • (1992) Stroke , vol.23 , pp. 663-667
    • Alberts, M.J.1    Faulstich, M.E.2    Gray, L.3
  • 12
    • 0026471210 scopus 로고
    • Use of fluid-attenuated inversion-recovery pulse sequences for imaging the spinal cord
    • White SJ, Hajnal JV, Young IA, Bydder GM. Use of fluid-attenuated inversion-recovery pulse sequences for imaging the spinal cord. Magn Reson Med. 1992;28:153-162.
    • (1992) Magn Reson Med , vol.28 , pp. 153-162
    • White, S.J.1    Hajnal, J.V.2    Young, I.A.3    Bydder, G.M.4
  • 14
    • 85035168630 scopus 로고
    • Application of prolonged inversion and echo time inversion recovery (PIETIR) pulse sequences to diagnosis of disease of the brain
    • Berkeley, Calif: Society of Magnetic Resonance in Medicine; Abstract
    • Hajnal JV, De Coene B, Cowan FM. Application of prolonged inversion and echo time inversion recovery (PIETIR) pulse sequences to diagnosis of disease of the brain. In: Book of Abstracts: Society of Magnetic Resonance in Medicine. Berkeley, Calif: Society of Magnetic Resonance in Medicine; 1992:1007. Abstract.
    • (1992) Book of Abstracts: Society of Magnetic Resonance in Medicine , pp. 1007
    • Hajnal, J.V.1    De Coene, B.2    Cowan, F.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.