메뉴 건너뛰기




Volumn 57, Issue 4, 1996, Pages 356-364

Local ventilation for powder handling - Combination of local supply and exhaust air

Author keywords

computational fluid dynamics; dust control; local ventilation; manual powder handling

Indexed keywords

AIRBORNE PARTICLE; AMBIENT AIR; ARTICLE; BREATHING; EXHAUST GAS; GRAVIMETRY; INDUSTRIAL HYGIENE; MATERIALS HANDLING; NONHUMAN; OCCUPATIONAL EXPOSURE; POWDER; ROOM VENTILATION; VELOCITY; WORK ENVIRONMENT;

EID: 0029991239     PISSN: 00028894     EISSN: None     Source Type: Journal    
DOI: 10.1080/15428119691014891     Document Type: Article
Times cited : (20)

References (28)
  • 2
    • 0025917150 scopus 로고
    • Clinical and immunological responses to occupational exposure to α-amylase in the baking industry
    • Brisman, J. and L. Belin: Clinical and immunological responses to occupational exposure to α-amylase in the baking industry. Br. J. Ind. Med. 48:604-608 (1991).
    • (1991) Br. J. Ind. Med. , vol.48 , pp. 604-608
    • Brisman, J.1    Belin, L.2
  • 3
    • 0009700146 scopus 로고
    • The Nordic expert group for criteria documentation of health risks from chemicals, 111. Industrial enzymes
    • Brisman, J.: The Nordic expert group for criteria documentation of health risks from chemicals, 111. Industrial enzymes. Arbete och Hälsa 28:1-25 (1994).
    • (1994) Arbete Och Hälsa , vol.28 , pp. 1-25
    • Brisman, J.1
  • 6
    • 0347542923 scopus 로고
    • Evaluation of a local ventilation unit for controlling styrene exposure
    • Cincinnati, OH: American Conference of Governmental Industrial Hygienists
    • Andersson, I-M., R. Niemelä, G. Rosen, I. Welling, et al.: Evaluation of a local ventilation unit for controlling styrene exposure. In Ventilation '91. Cincinnati, OH: American Conference of Governmental Industrial Hygienists, 1993. pp. 161-166.
    • (1993) Ventilation '91 , pp. 161-166
    • Andersson, I.-M.1    Niemelä, R.2    Rosen, G.3    Welling, I.4
  • 7
    • 0025546753 scopus 로고
    • Using low-velocity air patterns to improve the operator's environment at industrial work stations
    • Chamberlin, L.A.: Using low-velocity air patterns to improve the operator's environment at industrial work stations. ASHRAE Trans. 96:757-762 (1990).
    • (1990) ASHRAE Trans. , vol.96 , pp. 757-762
    • Chamberlin, L.A.1
  • 8
    • 0024465245 scopus 로고
    • Workstation design improvements for reduction of dust exposures during weighing of chemical powders
    • Gressel, M.G. and T.J. Fischbach: Workstation design improvements for reduction of dust exposures during weighing of chemical powders. Appl. Ind. Hyg. 9:227-233 (1989).
    • (1989) Appl. Ind. Hyg. , vol.9 , pp. 227-233
    • Gressel, M.G.1    Fischbach, T.J.2
  • 9
    • 0018834222 scopus 로고
    • Dust control concepts in chemical handling and weighing
    • Hammond, C.M.: Dust control concepts in chemical handling and weighing. Ann Occup. Hyg. 23:95-109 (1980).
    • (1980) Ann Occup. Hyg. , vol.23 , pp. 95-109
    • Hammond, C.M.1
  • 12
    • 9044249751 scopus 로고
    • An experimental and numerical study of the capture of pollutants over a surface treatment tank equipped with a suction slot
    • Cincinnati, OH: ACGIH
    • Braconnier, R., R. Régnier, and F. Bonthoux: An experimental and numerical study of the capture of pollutants over a surface treatment tank equipped with a suction slot. In Ventilation '91. Cincinnati, OH: ACGIH, 1993. pp. 95-105.
    • (1993) Ventilation '91 , pp. 95-105
    • Braconnier, R.1    Régnier, R.2    Bonthoux, F.3
  • 13
    • 3943067456 scopus 로고
    • Auslegung von Einrichtungen zur Schadstoffertassung. HLH
    • German
    • Scholer, W.: Auslegung von Einrichtungen zur Schadstoffertassung. HLH, Z. Heiz. Lüft., Klimatech., Haustech. 44:506-507 (1993). [German]
    • (1993) Z. Heiz. Lüft., Klimatech., Haustech. , vol.44 , pp. 506-507
    • Scholer, W.1
  • 14
    • 0027686262 scopus 로고
    • Numerical calculation of air flow fields generated by exhaust openings
    • Kulmala, I.: Numerical calculation of air flow fields generated by exhaust openings. Ann. Occup. Hyg. 37:451-467 (1993).
    • (1993) Ann. Occup. Hyg. , vol.37 , pp. 451-467
    • Kulmala, I.1
  • 15
    • 0028484669 scopus 로고
    • Numerical simulation of a local ventilation unit
    • Kulmala, I.: Numerical simulation of a local ventilation unit. Ann. Occup. Hyg. 38:337-349 (1994).
    • (1994) Ann. Occup. Hyg. , vol.38 , pp. 337-349
    • Kulmala, I.1
  • 16
    • 9044231408 scopus 로고
    • Effect of exhaust opening location on dust exposure during powder weighing
    • Heinonen, K. and I. Kulmala: Effect of exhaust opening location on dust exposure during powder weighing. Arbete och Hälsa 18:339-344 (1994).
    • (1994) Arbete Och Hälsa , vol.18 , pp. 339-344
    • Heinonen, K.1    Kulmala, I.2
  • 18
    • 0018480361 scopus 로고
    • A stable and accurate convective modelling procedure based on quadratic upstream interpolation
    • Leonard, B.P.: A stable and accurate convective modelling procedure based on quadratic upstream interpolation. Camp. Meth. Appl. Mech. Eng. 19:59-98 (1976).
    • (1976) Camp. Meth. Appl. Mech. Eng. , vol.19 , pp. 59-98
    • Leonard, B.P.1
  • 20
    • 0023711492 scopus 로고
    • Dust control with clean air from an overhead air supply island (OASIS)
    • Volkwein, J.C., M.R. Engle, and T.D. Raether: Dust control with clean air from an overhead air supply island (OASIS). Appl. Ind. Hyg. 3:236-239 (1988).
    • (1988) Appl. Ind. Hyg. , vol.3 , pp. 236-239
    • Volkwein, J.C.1    Engle, M.R.2    Raether, T.D.3
  • 21
    • 0346912139 scopus 로고
    • Evaluation of a ceiling-mounted low-impulse air inlet unit for local control of air pollution
    • Cincinnati, OH: American Conference of Governmental Industrial Hygienists
    • Andersson, I-M., G. Rosén, and J. Kristensson: Evaluation of a ceiling-mounted low-impulse air inlet unit for local control of air pollution. In Ventilation '91. Cincinnati, OH: American Conference of Governmental Industrial Hygienists, 1993. pp. 209-213.
    • (1993) Ventilation '91 , pp. 209-213
    • Andersson, I.-M.1    Rosén, G.2    Kristensson, J.3
  • 22
    • 0345324794 scopus 로고
    • A mobile local ventilation system equipped with an automatic position control
    • Säämänen, A. and S. Enbom: A mobile local ventilation system equipped with an automatic position control. Arbete och Hälsa 18:307-312 (1994).
    • (1994) Arbete Och Hälsa , vol.18 , pp. 307-312
    • Säämänen, A.1    Enbom, S.2
  • 24
    • 0037735688 scopus 로고
    • Dvizhenie vozdushnogo potoha k vytyazhnomu otverstiyu
    • Russian
    • Tyaglo, I.G. and I.A. Shepelev: Dvizhenie vozdushnogo potoha k vytyazhnomu otverstiyu. Vodosnab. Sanit. Tekh. 5:24-25 (1970). [Russian]
    • (1970) Vodosnab. Sanit. Tekh. , vol.5 , pp. 24-25
    • Tyaglo, I.G.1    Shepelev, I.A.2
  • 25
    • 0000847046 scopus 로고
    • Strömungsverhältnisse bei runden Saugöffnungen mit Flansch. HLH
    • German
    • Drkal, F.: Strömungsverhältnisse bei runden Saugöffnungen mit Flansch. HLH, Z. Heiz. Lüft., Klimatech., Haustech. 21(8):271-273 (1970). [German]
    • (1970) Z. Heiz. Lüft., Klimatech., Haustech. , vol.21 , Issue.8 , pp. 271-273
    • Drkal, F.1
  • 26
    • 0021879624 scopus 로고
    • The potential flow solution for air flow into a flanged circular hood
    • Flynn, M.R. and M.J. Ellenbecker: The potential flow solution for air flow into a flanged circular hood. Am. Ind. Hyg. Assoc. J. 46:318-322 (1985).
    • (1985) Am. Ind. Hyg. Assoc. J. , vol.46 , pp. 318-322
    • Flynn, M.R.1    Ellenbecker, M.J.2
  • 27
    • 0024423272 scopus 로고
    • Finite difference methods for computation of flow into local exhaust hoods
    • Anastas, M.Y. and R.T. Hughes: Finite difference methods for computation of flow into local exhaust hoods. Am. Ind. Hyg. Assoc. J. 50:526-534 (1989).
    • (1989) Am. Ind. Hyg. Assoc. J. , vol.50 , pp. 526-534
    • Anastas, M.Y.1    Hughes, R.T.2
  • 28
    • 0029026336 scopus 로고
    • Numerical calculation of an air flow field near an unflanged circular exhaust opening
    • Kulmala, I. and P. Saarenrinne: Numerical calculation of an air flow field near an unflanged circular exhaust opening. Staub Reinh. Luft 55:131-135 (1995).
    • (1995) Staub Reinh. Luft , vol.55 , pp. 131-135
    • Kulmala, I.1    Saarenrinne, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.