메뉴 건너뛰기




Volumn 60, Issue 2, 1996, Pages 85-95

Measurement of left ventricular volume by dual-field conductance catheter in humans - Comparison with single-field conductance catheter

Author keywords

Dual field conductance catheter; Left ventricular volume measurement; Segmental stroke volume; Single field conductance catheter

Indexed keywords

ADULT; AGED; ARTICLE; CINEANGIOCARDIOGRAPHY; CLINICAL ARTICLE; CLINICAL TRIAL; CONDUCTANCE; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC IMAGING; FEMALE; HEART CATHETERIZATION; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART LEFT VENTRICLE VOLUME; HEART STROKE VOLUME; HUMAN; ISCHEMIC HEART DISEASE; MALE;

EID: 0029986802     PISSN: 13469843     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (22)
  • 1
    • 0023892678 scopus 로고
    • Angiographic validation of eigenvolume to measure left ventricular size
    • Chagas ACP, Glantz SA: Angiographic validation of eigenvolume to measure left ventricular size. Circ Res 1988; 62: 1237-1246
    • (1988) Circ Res , vol.62 , pp. 1237-1246
    • Chagas, A.C.P.1    Glantz, S.A.2
  • 2
    • 0020665264 scopus 로고
    • Assessment of left ventricular pressure-volume relations using gated radionuclide angiography, echocardiography, and micromanometer pressure recordings
    • Magorien DJ, Shaffer P, Bush CA, Magorien RD, Kolibash AJ, Leier CV, Bashore TM: Assessment of left ventricular pressure-volume relations using gated radionuclide angiography, echocardiography, and micromanometer pressure recordings. Circulation 1983; 67: 844-853
    • (1983) Circulation , vol.67 , pp. 844-853
    • Magorien, D.J.1    Shaffer, P.2    Bush, C.A.3    Magorien, R.D.4    Kolibash, A.J.5    Leier, C.V.6    Bashore, T.M.7
  • 3
    • 0018679823 scopus 로고
    • Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. A comparison of cineangiographic and radionuclide techniques
    • Folland ED, Parisi AF, Moynihan PF, Jones DR, Feldman CL, Tow DE: Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. A comparison of cineangiographic and radionuclide techniques. Circulation 1979; 60: 760-766
    • (1979) Circulation , vol.60 , pp. 760-766
    • Folland, E.D.1    Parisi, A.F.2    Moynihan, P.F.3    Jones, D.R.4    Feldman, C.L.5    Tow, D.E.6
  • 4
    • 0025286923 scopus 로고
    • Left ventricular volume measurement using cardiac axis nuclear magnetic resonance imaging: Validation by calibrated ventricular angiography
    • Cranney GB, Lotan CS, Dean L, Baxley W, Bouchard A, Pohost GM: Left ventricular volume measurement using cardiac axis nuclear magnetic resonance imaging: Validation by calibrated ventricular angiography. Circulation 1990; 82: 154-163
    • (1990) Circulation , vol.82 , pp. 154-163
    • Cranney, G.B.1    Lotan, C.S.2    Dean, L.3    Baxley, W.4    Bouchard, A.5    Pohost, G.M.6
  • 7
    • 0021286288 scopus 로고
    • Computation of the input impedances of a catheter for cardiac volumetry
    • Mur G, Baan J: Computation of the input impedances of a catheter for cardiac volumetry. IEEE Trans Biomed Eng 1984; 31: 448-453
    • (1984) IEEE Trans Biomed Eng , vol.31 , pp. 448-453
    • Mur, G.1    Baan, J.2
  • 8
    • 0021854779 scopus 로고
    • Accuracy of volume measurement by conductance catheter in isolated, ejecting canine hearts
    • Burkhoff D, Van Der Velde E, Kass D, Baan J, Maughan WL, Sagawa K: Accuracy of volume measurement by conductance catheter in isolated, ejecting canine hearts. Circulation 1985; 72: 440-447
    • (1985) Circulation , vol.72 , pp. 440-447
    • Burkhoff, D.1    Van Der Velde, E.2    Kass, D.3    Baan, J.4    Maughan, W.L.5    Sagawa, K.6
  • 9
    • 0023752301 scopus 로고
    • Left ventricular volume determination in dogs: A comparison between conductance technique and angiocardiography
    • Tjon-A-Meeuw L, Hess OM, Nonogi H, Monrad ES, Leskosek B, Krayenbuehl HP: Left ventricular volume determination in dogs: A comparison between conductance technique and angiocardiography. Eur Heart J 1988; 9: 1018-1026
    • (1988) Eur Heart J , vol.9 , pp. 1018-1026
    • Tjon-A-Meeuw, L.1    Hess, O.M.2    Nonogi, H.3    Monrad, E.S.4    Leskosek, B.5    Krayenbuehl, H.P.6
  • 10
    • 0026496226 scopus 로고
    • Determination of left ventricular volume using conductance catheter in human diseased heart
    • Odake M, Takeuchi M, Takaoka H, Hata K, Hayashi Y, Yokoyama M: Determination of left ventricular volume using conductance catheter in human diseased heart. Eur Heart J 1992; 13: 22-27
    • (1992) Eur Heart J , vol.13 , pp. 22-27
    • Odake, M.1    Takeuchi, M.2    Takaoka, H.3    Hata, K.4    Hayashi, Y.5    Yokoyama, M.6
  • 11
    • 3042945375 scopus 로고
    • Total and segmental LV volume by dual excitation of the conductance catheter
    • Steendijk P, Bouman P, Van Der Velde ET, Baan J: Total and segmental LV volume by dual excitation of the conductance catheter (abstract). Circulation 1989; 10(Suppl): 337
    • (1989) Circulation , vol.10 , Issue.SUPPL. , pp. 337
    • Steendijk, P.1    Bouman, P.2    Van Der Velde, E.T.3    Baan, J.4
  • 12
    • 0026468321 scopus 로고
    • Single and dual excitation of the conductance-volume catheter analysed in a spheroidal mathematical model of the canine left ventricle
    • Steendijk P, Van Der Velde ET, Baan J: Single and dual excitation of the conductance-volume catheter analysed in a spheroidal mathematical model of the canine left ventricle. Eur Heart J 1992; 13(Suppl): 28-34
    • (1992) Eur Heart J , vol.13 , Issue.SUPPL. , pp. 28-34
    • Steendijk, P.1    Van Der Velde, E.T.2    Baan, J.3
  • 14
    • 0027531545 scopus 로고
    • Comparison of hemodynamic determinants for myocardial oxygen consumption under different contractile states in human ventricle
    • Takaoka H, Takeuchi M, Odake M, Hayashi Y, Hata K, Mori M, Yokoyama M: Comparison of hemodynamic determinants for myocardial oxygen consumption under different contractile states in human ventricle. Circulation 1993; 87: 59-69
    • (1993) Circulation , vol.87 , pp. 59-69
    • Takaoka, H.1    Takeuchi, M.2    Odake, M.3    Hayashi, Y.4    Hata, K.5    Mori, M.6    Yokoyama, M.7
  • 15
    • 0023796309 scopus 로고
    • Use of a conductance (volume) catheter and transient inferior vena caval occlusion for rapid determination of pressure-volume relationships in man
    • Kass DA, Midei M, Graves W, Brinker JA, Maughan WL: Use of a conductance (volume) catheter and transient inferior vena caval occlusion for rapid determination of pressure-volume relationships in man. Cathet Cardiovasc Diagn 1988; 15: 192-202
    • (1988) Cathet Cardiovasc Diagn , vol.15 , pp. 192-202
    • Kass, D.A.1    Midei, M.2    Graves, W.3    Brinker, J.A.4    Maughan, W.L.5
  • 16
    • 0024429821 scopus 로고
    • Left ventricular volume measurement by conductance catheter in intact dogs
    • Boltwood CM, Appleyard RF, Glantz SA: Left ventricular volume measurement by conductance catheter in intact dogs. Circulation 1989; 80: 1360-1377
    • (1989) Circulation , vol.80 , pp. 1360-1377
    • Boltwood, C.M.1    Appleyard, R.F.2    Glantz, S.A.3
  • 17
    • 0027254994 scopus 로고
    • Left ventricular stroke volume by single and dual excitation of conductance catheter in dogs
    • Steendijk P, Van Der Velde ET, Baan J: Left ventricular stroke volume by single and dual excitation of conductance catheter in dogs. Am J Physiol 1993; 33: H2198-H2207
    • (1993) Am J Physiol , vol.33
    • Steendijk, P.1    Van Der Velde, E.T.2    Baan, J.3
  • 18
    • 0025020618 scopus 로고
    • Simultaneous conductance catheter and dimension assessment of left ventricle volume in the intact animal
    • Applegate RJ, Cheng CP, Little WC: Simultaneous conductance catheter and dimension assessment of left ventricle volume in the intact animal. Circulation 1990; 81: 638-648
    • (1990) Circulation , vol.81 , pp. 638-648
    • Applegate, R.J.1    Cheng, C.P.2    Little, W.C.3
  • 20
    • 0023850646 scopus 로고
    • Does normal pump function belie muscle dysfunction in patients with chronic severe mitral regurgitation?
    • Wisenbaugh T: Does normal pump function belie muscle dysfunction in patients with chronic severe mitral regurgitation? Circulation 1988; 77: 515-525
    • (1988) Circulation , vol.77 , pp. 515-525
    • Wisenbaugh, T.1
  • 21
    • 0021086082 scopus 로고
    • Evaluation of left ventricular contractile pattern by intravenous digital subtraction ventriculography: Comparison with cineangiography and assessment of interobserver variability
    • Nissen SE, Booth D, Waters J, Fassas T, Demaria AN: Evaluation of left ventricular contractile pattern by intravenous digital subtraction ventriculography: comparison with cineangiography and assessment of interobserver variability. Am J Cardiol 1983; 52: 1293-1298
    • (1983) Am J Cardiol , vol.52 , pp. 1293-1298
    • Nissen, S.E.1    Booth, D.2    Waters, J.3    Fassas, T.4    Demaria, A.N.5
  • 22
    • 0025905026 scopus 로고
    • Use of intravenous digital subtraction ventriculography in the evaluation of left ventricle volumes and ejection fraction
    • Perondi R, Gregorini L, Pomidossi G, Saino A, Zanchetti A, Mancia G: Use of intravenous digital subtraction ventriculography in the evaluation of left ventricle volumes and ejection fraction. Eur Heart J 1991; 12: 363-367
    • (1991) Eur Heart J , vol.12 , pp. 363-367
    • Perondi, R.1    Gregorini, L.2    Pomidossi, G.3    Saino, A.4    Zanchetti, A.5    Mancia, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.